{"id":23985,"date":"2021-01-04T12:54:44","date_gmt":"2021-01-04T12:54:44","guid":{"rendered":"https:\/\/ankersmid.eu\/?post_type=product&#038;p=23985"},"modified":"2022-02-15T07:42:44","modified_gmt":"2022-02-15T07:42:44","slug":"ncld-88-yp","status":"publish","type":"product","link":"https:\/\/ankersmid.eu\/index.php\/product\/ncld-88-yp\/","title":{"rendered":"nCLD 88 Yp"},"content":{"rendered":"<div class=\"et_pb_section et_pb_section_2 et_section_regular\">\n<div class=\"et_pb_row et_pb_row_2\">\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_column_5 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_tabs et_pb_tabs_0 \">\n<div class=\"et_pb_all_tabs\">\n<div class=\"et_pb_tab et_pb_tab_0 clearfix et_pb_active_content et-pb-active-slide\">\n<div class=\"et_pb_tab_content\">\n<div class=\"et_pb_section et_pb_section_2 et_section_regular\">\n<div class=\"et_pb_row et_pb_row_2\">\n<div class=\"et_pb_column et_pb_column_4_4 et_pb_column_5 et_pb_css_mix_blend_mode_passthrough et-last-child\">\n<div class=\"et_pb_module et_pb_tabs et_pb_tabs_0 \">\n<div class=\"et_pb_all_tabs\">\n<div class=\"et_pb_tab et_pb_tab_0 clearfix et_pb_active_content et-pb-active-slide\">\n<div class=\"et_pb_tab_content\">\n<p><strong>Precise and Reliable<br \/>\n<\/strong>The nCLD 88 Yp fulfills the requirements of many research groups specializing in detection and monitoring smallest variations of N-containing compounds, such as NO or NO<sub>X<\/sub>. The fully revised detector-block, the enhanced gas flow paths and the improved pressure as well as temperature independence of the nCLD 800 Series allow for even lower detection limits. Overall stability and reliability are lifted to a new level. The pre chamber of the nCLD 88 Yp also minimizes zero drift and cross sensitivity. This makes it ideally suited for areas with excellent air quality. The Calibration and the adjustment of the unit runs quick and automatic, ensuring unsurpassed precision and reliability.<\/p>\n<p><strong>User Friendliness<br \/>\n<\/strong>The new touch sensitive graphical user interface enables the user to individually adjust the instrument operation and data management according to his\/ her needs and applications. All necessary data is continuously and available. The bright 7\u201d monitor gives a clear overview and allows numerical and graphical display of values. Multiple digital in- and outputs guarantee a maximal connectivity and flexibility for the remote operation and maintenance of the nCLD 88 Yp.<\/p>\n<p><strong>Compact, Modular and Intelligent!<br \/>\n<\/strong>The nCLD 88 Yp is manufactured in a new compact and modular layout, in which each essential component of the chemiluminescence analyzer hosts its own CPU and interacts with other CPUs by BUS-communication. This assembly increases accessibility and serviceability by reducing wiring and piping. The measurement principle will conform to the standard method for NO<sub>X<\/sub>-detection in ambient air (EN 14211).<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<h4 class=\"et_pb_module_header\">ECO PHYSICS nCLD 88 Yp<\/h4>\n<div class=\"et_pb_blurb_description\">\n<p><strong>Modular Trace-Level Gas Analyzer<\/strong><\/p>\n<p>The nCLD 88 Yp is the next generation in measuring smallest amounts of NO or NO<sub>X<\/sub>. Unique in speed and precision, the nCLD 88 Yp is modular designed and allows the sequential measurement of concentrations even in the range of parts per trillion and is expandable to assess additional nitrogen oxide based parameters. Its new and intuitive user interface also individually displays and connects to other instruments\u2019 data.<\/p>\n<\/div>\n","protected":false},"featured_media":23957,"template":"","meta":[],"product_brand":[],"product_cat":[765,1096,1010,806],"product_tag":[],"class_list":["post-23985","product","type-product","status-publish","has-post-thumbnail","product_cat-gasanalyse","product_cat-5-ppb-5000-ppb","product_cat-eco-physics","product_cat-extractief","pa_gas-component-no","pa_gas-component-nox","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/ankersmid.eu\/index.php\/wp-json\/wp\/v2\/product\/23985","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ankersmid.eu\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/ankersmid.eu\/index.php\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ankersmid.eu\/index.php\/wp-json\/wp\/v2\/media\/23957"}],"wp:attachment":[{"href":"https:\/\/ankersmid.eu\/index.php\/wp-json\/wp\/v2\/media?parent=23985"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/ankersmid.eu\/index.php\/wp-json\/wp\/v2\/product_brand?post=23985"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/ankersmid.eu\/index.php\/wp-json\/wp\/v2\/product_cat?post=23985"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/ankersmid.eu\/index.php\/wp-json\/wp\/v2\/product_tag?post=23985"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}