• Adsorptiefilter type AAM

    voor adsorptie van interfererende componenten

    Ankersmid Universal Filters are known as a reliable technique for the adsorption of components in a gas stream that cause interferences in the gas measurement.

    The design of the filter and filter housing ensures that any liquids present in the gas will be separated and collected in the bottom of the filter-housing.

    The AAM series are based on the elements of the AUF universal filter series.

    Due to its universal standard design, the filters can be used with various adsorption cartridges and, if needed, also be fitted with a liquid sensor.

  • Aerosolfilter type AFP

    voor filtreren van vloeibare deeltjes

    The Ankersmid fluid particle filter or coalescence filter is suitable for filtration of fluid particles of all types and is recommended for sample gases with an acid dew point above 100 °C. Application examples are measurements in flue gas of heavy oil and black coal combustions.

    The filter separates the aerosols (very fine fluid particles) which still pass the gas cooler. The most effective position of the filter is downstream the sample conditioning close to the flow meter of the analyser. For additional system protection we provide the version with integrated hydrophobic diaphragm, working as a liquid stop.

  • AII GPR-1200/3500

    Gemakkelijke tracering en meting van zuivere zuurstof
    De zeer nauwkeurige draagbare zuurstofanalysatoren van Analytical Industries zijn bedoeld voor toepassingen die op verschillende gedefinieerde meetpunten moeten worden gecontroleerd. Het GPR-3500-model heeft een compacte, robuuste behuizing en bevat roestvrijstalen onderdelen die in contact komen met de vloeistof, geïntegreerde debietmeters en naaldventielen. Het meet de zuiverheid voor inerte gassen, kooldioxide en zuurstof. De GPR-1200 compacte draagbare zuurstofanalyser voor sporen heeft een 4-wegklep die een gasmonster in de sensor opvangt. Dit maakt snellere zuurstofmeettijden mogelijk bij het verplaatsen van punt naar punt in een proces en beschermt ook sporenzuurstofsensoren tegen voortijdige uitputting als gevolg van blootstelling aan omgevingszuurstofniveaus om hun levensduur te verlengen. Dit alles zorgt voor een zuinige werking en lage eigendomskosten voor deze toonaangevende reeks draagbare zuurstofanalysers.
  • The air purifier CAP 15 and air purifier CAP 30 produces clean and hydrocarbon-free air out of normal compressed air. The Pt/Pd-catalyst convert by catalytical total-oxidation at 370°C all hydrocarbons inclusive methane (CH4) into carbondioxyde (CO2) and water (H2O). Hydrogen (H2) and carbonmonoxyde (CO) will be removed quantitatively.The produced air quality ist constantly free of hydrocarbons and better than sythetic air from gas bottles of class 5.0 (refering to organic components).On account of the high gas purity, the air purifier CAP 15/30 are used for FID-measuring systems as combustion air and as zero gas
  • ASP 320 DeNox

    DeNOx-processen (SCR)
    The probe type ASP 320 is based on the standard Ankersmid sample probe. Due to its modular and innovative design the Ankersmid heated sample probe cover also meet the special requirements of above mentioned application. With the heated filter body a filter element of 150mm length, suitable for most applications up to 1g dust/m3, is integrated. When the integrated port is used for back-flush higher dust loads can be handled. Additional a pre-filter can be mounted on top of the sample probe. The filter element can be replaced without any tools and in the shortest possible time. At the sample gas outlet of the probe a special non-heated condensate vessel of glass is mounted. It is filled with glass balls to extend the surface for the salification. The salt deposits and will be washed out with the condensate. A peristaltic pump type ASR25 continuously removes the condensate with the solved ammonium salts. The temperature of the vessel is higher than the ambient temperature because of the hot gas stream. Therefore a loss of measured components is negligible because of warm condensate. In case of a DeNOx application with a small content of NH3 (normally only a few ppm) it is possible to analyse SO2 and NOX without great losses (only some ppm which normally can be neglected). To determine the loss, it is possible to give test gas via the probe to the analyser(s). A measuring fault can be found and calibrated. As an option the vessel can be heated as well to suppress chemical reactions of the measured component below a defined temperature. At the sample outlet of the vessel a heated gas sample line series AHL can be connected.
  • ATEX in-situ oxygen analysers

    Ex-proof in situ zirconia oxygen analyzer for combustion control
    Ex-proof in situ zirconia oxygen analyzer for combustion control
    The oxygen measurement enables the control of burner fuel/air ratios to ensure combustion efficiency and process safety. Fuji Electric O2 Analyser is adapted to be installed in hazardous areas and to withstand critical environments as:
    • Refinery process heaters
    • Petrochemical reactor furnaces
    • Industrial large scale boilers
  • atmosFIR

    Multi-component FTIR gas analyser, measuring sub-ppm to low %Vol online
    atmosFIR is the successor to Protea's previous emissions monitoring FTIR systems, keeping all the features that users found valuable in achieving their measurement results, but offering the benefits of the new atmosFIR platform with increased portability, lower ownership costs and increased measurement performance. atmosFIR can be considered a simple multi-gas analyser for combustion gas measurements; indeed for some users that is all it will be and as such it provides a cost-effective and complete measurement system. However, for the expert user atmosFIR will offer all the benefits of FTIR, with hundreds of gas measurements, multiple analytical ranges, in-depth chemometric result diagnoses and dedicated on-board sampling system. With Protea's in-house chemometrics application support and 15+ year history of emission monitoring projects, atmosFIR offers the user the complete package for their monitoring needs. With long-lifetime VCSEL reference laser diode, unique cell design, and air cooled DTGS detector with 24-bit ADC, atmosFIR is a step-change in value and service lifetime for FTIR emission gas analysis.
  • atmosFIR CEM

    Continuous Emissions Monitoring FTIR
    atmosFIR CEM is a complete emissions monitoring system incorporating the atmosFIR 19” FTIR analyser. As completely hot and wet emissions measurement, atmosFIR CEM is ideal for complete measurement of multiple gases from applications such as incineration and power. A standard gas suite of NO, NO2, N2O, SO2, NH3, HCl, CH4, O2, CO2 and H2O is provided, but with the powerful FTIR analyser, further gases can be added easily in software. At the heart of system is the high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIR has been developed to incorporate the latest improvements and advantages in technology, The atmosFIR FTIR analyser contains an in-built sampling system and is designed for ppm-level emissions monitoring. The analyser can be used as a portable or bench-top unit as well as part of the installed CEM system.
  • atmosFIRt

    Draagbare multigas FTIR gasanalyser voor emissiemeting
    atmosFIRt is the latest generation of FTIR gas analyser technology from Protea in a portable or mobile form. The atmosFIR system improves upon previous FTIR technology and represents one of the most cost-effective and flexible analytical products on the market today. At the heart of atmosFIR is a high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIR has been developed to incorporate the latest improvements and advantages in technology.
  • atmosFIRw

    Wall-mounted multigas analyser for ambient air and process monitoring
    atmosFIR is the latest generation of gas analyser technology from Protea. The atmosFIR system improves upon previous FTIR technology and represents one of the most cost-effective and flexible analytical products on the market today. atmosFIRw has been designed to give a complete measurement system with embedded touchscreen controller. At the heart of atmosFIRw is a high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIRw has been developed to incorporate the latest improvements and advantages in technology, including:
    • Low cost of ownership and maintenance
    • Robust and light, including the latest in fabrication materials
    • atmosFIR combines an FTIR analyser with an in-built sampling system and embedded PC controller for a complete system
  • Automatic calibration unit

    Automatic calibration system for the Mercury Ultratracer UT-3000
    The static calibration unit is meant for automatically calibrating the UT-3000 Mercury Ultratracer in natural gas monitoring systems for low to intermediate mercury concentrations.
  • The heated sampling system is a combination of a heated sample line and a heated sample filter. The sample line is 500mm long; the filter element can be replaced very quick with the bayonet lock. Beside the very precisious and constant regulation of the line and filter temperature, there is a separate controll point fort he temperature at the filterinlet, where you have an information of the exhaust gas temperature. Also the calibration gas (prewarmed) can directly connected with the unit. The thermocouple is available as PT 100 or NiCrNi.
  • Backscatter probes

    0.0005% (10 NTU) to 100% solids
    Kemtrak backscatter probes are designed to accurately measure low to extremely high turbidity directly in tanks and pipelines. The dual fiber optic design of the Kemtrak probe provides high resolution at low turbidity ranges with excellent linearity all the way up to extremely high turbidities when used with a Kemtrak NBP007 backscatter photometer. A unique benefit of the Kemtrak backscatter immersion probe is that it does not go blind at high sample turbidities. Other probes stop working at 4 000 NTU/FNU (< 1 wt% solids) after which the signal will decrease resulting in an erroneous and misleading output. The output of the Kemtrak probe will continue to increase with sample concentration ensuring a reliable measurement.  
  • Backwash M1

    Filter Model iFiD
    The heated prefilter model iFiD Filter Backwash M1is a samplegasfilter which can flushbacked with an electronic solenoid valve. This valve can controll the pressure air (flushbackair) and the sample gas. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Backwash M2

    Filter iFiD
    The heated prefilter model iFiD Backwash M2 is a samplegasfilter which can be flushbacked. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Calibrator MC-3000

    Mercury calibration gas generator
    The MC-3000 is used for generating a continuous stream of a mercury vapor loaded gas stream in order to check or calibrate mercury analyzers. It is also suitable for all those applications where a gas stream with a preset and constant mercury concentration is needed.
    • Generates elemental mercury vapor
    • continuous operation
    • approx. 10 ... 500 µg/m³ Hg°
    • Compact and portable size
    • No permeation principle - no need to calibrate the calibrator
    • Microprocessor controlled

Titel

Ga naar de bovenkant