• nCLD 811 M

    NO, NO2 , NOx - 1 ppm - 10’000 ppm

    ECO PHYSICS nCLD 811 M

    SupremeLine Gas Analyzer The nCLD 811 M is the next generation in two-channel emissions monitoring instrumentation. Unique in speed and reliability, the nCLD 811 M is modular designed and allows the continuous and simultaneous analysis of NO, NO2 and NOX in raw exhaust gasses with NOX concentrations ranging from several thousand ppm down to a ppb. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 811 CM

    NO, NO2, NOx, NH3, NOx – Amines - 1 ppm -10’000 ppm
    SupremeLine Gas Analyzer The nCLD 811 CM is the next generation in two-channel emissions monitoring instrumentation. Unique in speed and reliability, the nCLD 811 CM is modular designed and allows the continuous analysis of NO, NO2, NOX, NH3 and NOX-Amines in raw exhaust gasses and other samples with NOX concentrations ranging from several thousand ppm down to a ppb. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 66 Y

    NO / NOx - 50 ppb – 25’000 ppb

    ECO PHYSICS nCLD 66 Y

    Gas Analyzer The nCLD 66 Y is the next generation in single-channel ambient air monitoring instrumentation. Unique in speed and precision, the nCLD 66 Y is modular designed and capable of sequentially measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen oxide based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 63 MOx

    NO / NOx O2, CO2 - 0.5 ppm – 500 ppm

    ECO PHYSICS nCLD 63 MOx

    Multi-Gas Analyzer The nCLD 63 MOx is the next generation in measuring NO/NOx , O2 and CO2. Unique in speed and precision, the nCLD 63 MOx is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principles comply with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
  • nCLD 62 MOx

    NO / NOx O2, CO2 - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 62 MOx

    Multi-Gas Analyzer The nCLD 62 MOx is the next generation in measuring NO/NOX , O2 and CO2. Unique in speed and precision, the nCLD 62 MOx is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principles comply with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
  • The analyzers can measure the concentration of multiple gases simultaneously. It is based on the single source dual-beam non-dispersion infrared (NDIR) method for CO, CO2 , CH4 , CnHm, H2S , SO2 and a micro-TCD (Thermal Conductivity Detector) gas sensor for H2 and O2 by fuel cell method. The analyzers have a digital pulsable infrared source and dual-beam systems
  • The gasstation is fitted with all supplygases who are necessary for a FID measurement. Hydrogen as the fuel gas, nitrogen as zerogas and propane as the calibration gas are available in the one liter bottles who allows a very good handling in mobile measurement. The FID can be connected via teflon hoses and quick connectors.
  • The Protea 2000 emissions monitoring system is approved forthe analysis of exhaust gases from the engines and boilers of ships and offshore rigs. Robust and with proven reliability, up to six gases can be measured including SO2,CO2 The Protea 2000 emissions monitoring system comprises up to 8 exhaust mounted analysers, each with automatic verification facilities. Emissions data from the entire system is securely managed and displayed at a dedicated Classification Society approved panel PC, with outputs to networks, control systems, and reporting facilities.
  • The ALS liquid-stop protects analyzers against an inrush of liquids from the gas conditioning unit into the analyzer.

    This avoids major damages of the analyser.

    The best position of the liquid is behind the gas conditioning unit, and before the flow meter going to the analyser.

  • LaserInspect CIMO4

    All-in-one controle paneel voor de LaserGas™ familie
    NEO Monitors’ LaserInspect™ CIMO4 gives the operator the opportunity to remotely operate up to 4 LaserGas™ analyzers from the same display*. The operator have full status overview in an instance of all instruments and is able to perform maintenance tasks directly from the panel. This HMI is designed for the NEO Monitors LaserGas™ family and can easily be integrated into a cabinet. * Separate Ethernet switch is required to operate multiple analyzers
  • LaserGas™ III Ultra

    Voor toepassingen met zeer lange padlengtes en hoge gasconcentraties

    LaserGas™ III Ultra

    It uses the innovative baseline-insensitive TDLAS technique specifically designed for combustion analysis. The Ultra simultaneously meets the requirements of combustion control and safety. That is, high measurement accuracy and high dynamic range with simultaneous real-time measurement capability. Applications with very long path lengths and high gas concentrations are no problem for the Ultra. Thanks to the baseline insensitivity and the use of the proprietary IROSS signal processing, high measurement accuracy is achieved even with complex gas mixtures. LaserGas™ III Ultra CO in combination with LaserGas™ III O2 are a perfect combination for proper combustion control and safety.
  • LaserGas Q ICL

    In-situ Interband Cascade Laser voor SO2, NO, NO2 of HBr
    In tegenstelling tot de vorige generaties LaserGas™-producten, meet de LaserGas™ Q-familie in het mid-infraroodspectrum, wat betere detectielimieten mogelijk maakt. Evenals detectie van gassen die niet mogelijk zijn met de meer gebruikelijke nabij-infraroodspectroscopie. De sensor heeft lage onderhoudskosten en vereist geen regelmatig onderhoud. De afwezigheid van extractieve conditioneringssystemen verbetert de beschikbaarheid van de metingen verder en elimineert fouten met betrekking tot monsterbehandeling. De monitor is direct op flenzen gemonteerd, die zijn voorzien van spoelgasaansluitingen en een kantelmechanisme voor eenvoudige uitlijning. Een continue spoelstroom voorkomt dat stof en andere verontreinigingen zich op de optische vensters nestelen. Zodra stroom- en datalijnen zijn aangesloten, worden metingen in realtime uitgevoerd. Download datasheet
  • LaserGas Q CF4

    Meet in het mid-infrarood spectrum met lage detectielimiet
    In tegenstelling tot de vorige generaties LaserGas™-producten, meet de LaserGas™ Q-familie in het mid-infraroodspectrum, wat betere detectielimieten mogelijk maakt. Evenals detectie van gassen die niet mogelijk zijn met de meer gebruikelijke nabij-infraroodspectroscopie. De sensor heeft lage onderhoudskosten en vereist geen regelmatig onderhoud. De afwezigheid van extractieve conditioneringssystemen verbetert de beschikbaarheid van de metingen verder en elimineert fouten met betrekking tot monsterbehandeling. De monitor is direct op flenzen gemonteerd, die zijn voorzien van spoelgasaansluitingen en een kantelmechanisme voor eenvoudige uitlijning. Een continue spoelstroom voorkomt dat stof en andere verontreinigingen zich op de optische vensters nestelen. Zodra stroom- en datalijnen zijn aangesloten, worden metingen in realtime uitgevoerd.
  • LaserGas iQ² Vulcan

    Single-flange O2, CO, CH4, H2O analyser
    LaserGas™ iQ2 Vulcan is the first in-situ single-flange solution to measure up to four gases (O2, CO, CH4, H2O) as well as the process temperature in a single unit. Based on the well-proven and trusted tunable diode laser absorption spectroscopy (TDLAS) technology, the solution combines cutting-edge design and ground-breaking functionality. It is a complete combustion solution eliminating the need for multiple units. Advanced TDLAS technology enables unmatched reliability and durability. Installation costs of this all-in-one solution are significantly reduced since only one flange is needed. In addition, operational and maintenance costs are kept at a minimum.
  • LaserGas iQ²

    Meet tot 4 gassen O2, CO, CH4, H2O
    LaserGas™ iQ² analyzer is the first to measure up to four gases (O2, CO, CH4, H2O) and temperature depending on configuration, which eliminates the need for multiple units for combustion analysis. The cutting-edge design and ground-breaking functionality, ensures that the instrument delivers unmatched reliability and durability. Customers may replace existing analyzers where explosion risks or high maintenance issues are a huge concern.
  • LaserGas III SP

    Cross stack meting voor Atex Zone I, optie SIL2
    LaserGas™ III SP is the third generation in-situ analyzer, designed for safety applications with a special focus on SIL-applications and Ex-d. A compact sized instrument which is easy to install. The instrument is a placed in a sealed housing which eliminates the need for instrument purging.The instrument does not require regular maintenance. The monitor is mounted directly onto flanges, which include purge gas connections and a tilting mechanism for easy alignment. Continuous purge flow prevents dust and other contamination from settling on the optical windows. Once power and data lines are connected, measurements are performed in real-time.
Ga naar de bovenkant