Liebherr sensors

The self-sufficient measuring device for precise water content/moisture determination in the running process guarantees the highest quality and safety in EX-protected production environments, the further processing and refinement of very many emulsions and bulk materials.

The PC software enables fast and accurate calibration of the measured sections.

Liebherr offers sensors for the following device protection categories:

Gas EX-protection:

II 1/2 G Ex db/ia IIC T4 Ga/Gb*

Dust EX-protection:

II 1/2 D Ex tb/ia IIIC T135°C Da/Db*

*Subject to type approval

The sensors are installed directly in pipes or in tanks.

The sensors are used, for example, in oils, crude oils, paints, lacquers, ethanol, solvents as well as in bulk materials under explosive conditions.

Categories:

Markets

The WMS II sensors are permitted for the following markets:

In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility.

Once the system has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.

Technical data planarsensor P78-E

 

 

Suitable for use in potentially explosive atmospheres Dust – Zone 22
Physical principle Capacity determination in the high frequency stray field
Frequency 16 – 22 MHz
Measurement location Outside silo via baffle plate, on belt with sliding shoe carriage, pipes, screw conveyors, tank, etc.
Measuring range 0 – 100% moisture content (measuring window adjustable)
Capacity resolution 10 fF
Update cycle 33 ms
Sampling rate mean value counter 16 – 22 106
Maximum attainable measuring accuracy:
With optimum material-specific calibration, with
averaging with ideal flow behaviour with
Litronic FMS II Evaluation and transfer module/PC Software
+/- 0.05 % moisture content
Measurement value transfer digital: RS-485, multiprocessor log
Max. number of sensors on the bus 16
Maximum bus length 1200 m
Power supply 8 – 30V, 0.4 VA
Temperature measurement measuring range -10 – 90 °C
Measuring accuracy temperature measurement +/- 0.5 °C
Operating ambient temperature 5 – 72 °C
Working temperature – electronics -20 – 80 °C
Storage temperature -25 – 80 °C
Protection class IP68
Connection cable type UNITRONIC®ROBUST C 7×0.14 shielded
Connection cable length 6 m
Wearing protection Zirconium oxide (ZrO2Al2O3)
Housing/flange material V4A 1.4404 (Option: 1.4571)
Dimensions: Ø/Height 78/53/57 mm
Weight without cable 0.900 kg
Clamping flange weight 0.300 kg
Ex-protection 2014/34/EU ZELM 06 ATEX 3320X
Ex-marking Ex II 3D Ex tD A22 IP6x T85°C Dc

Technical data sensor P45-GD

 

Suitable for use in potentially explosive areas Dust/Gas – Zone 0/20
Measurement
Physical principle Capacity determination in the high frequency stray field
Measurement location Pipeline, Tank
Adjustable measuring range 0 – 100% moisture content (measuring window adjustable)
Number of scattered fields 1
Update cycle 50 ms
Achievable measurement accuracy ± 0.1 % with correct material curve
Temperature measurement accuracy ± 0.5 °C
Outflow
Measured value transmission – Sensor display content Current loop with “4 – 20 mA” for external display and control unit (option)
Measured value transmission – sensor PLC or main computer Analogue: “4 – 20 mA” active at 500 Ohm digital: Hart Modem, Modbus RTU
Valid measurement 3.75 mA to 21.6 mA (NAMUR)
Interface signal resolution 16 bit
Max. length of connecting cable 1000 m (depending on cable)
Power supply
Connection 24 V DC
15 V to 36 V DC
100 mA DC
Temperature
Medium temperature -5 °C to 80 °C (Standard)
-5 °C to 95° C (Option)
Ambient temperature -20 °C to 80 °C
Storage temperature -25 °C to 80 °C
Pressure
Pressure -1 bar to 100 bar
Material
Rod material V4A
1.4571, optional: 2.4819
Transmitter head material Aluminium
Measuring field material/wearing protection PEEK
Dimensions
Housing W/H/D 88 mm
160 mm
143 mm
Rod diameter 45 mm
Rod length 66 mm to 2000 mm
Measuring field material PEEK

Technical data planarsensor P45-GD

 

 

Suitable for use in potentially explosive areas Dust/Gas – Zone 0/20
Measurement
Physical principle Capacity determination in the high frequency stray field
Measurement location Pipeline
Adjustable measuring range 0 – 100% moisture content (measuring window adjustable)
Number of scattered fields 1
Update cycle 50 ms
Achievable measurement accuracy ± 0.1 % with correct material curve
Temperature measurement accuracy ± 0.5 °C
Outflow
Measured value transmission – Sensor display content Current loop with “4 – 20 mA” for external display and control unit (option)
Measured value transmission – sensor PLC or main computer Analogue: “4 – 20 mA” active at 500 Ohm digital: Hart Modem, Modbus RTU
Valid measurement 3.75 mA to 21.6 mA (NAMUR)
Interface signal resolution 16 bit
Max. length of connecting cable 1000 m (depending on cable)
Power supply
Connection 24 V DC
15 V to 36 V DC
100 mA DC
Temperature
Medium temperature -5 °C to 80 °C (Standard)
-5 °C to 95° C (Option)
Ambient temperature -20 °C to 80 °C
Storage temperature -25 °C to 80 °C
Pressure
Pressure -1 bar to 100 bar
Material
Housing material PEEK
Measuring field material/wearing protection Ceramic, ZrO2
Material of flange for bolting on/flange for welding on 1.4435 / 1.4571
Dimensions
Housing W/H 45 mm
112.6 mm
Cable length 2 m to 10 m

Technical data planarsensor P78-GD

Suitable for use in potentially explosive areas Dust/Gas – Zone 0/20
Measurement
Physical principle Capacity determination in the high frequency stray field
Measurement location Pipeline, bulk material
Adjustable measuring range 0 – 100% moisture content (measuring window adjustable)
Number of scattered fields 1
Achievable measurement accuracy ± 0.1 % with correct material curve
Temperature measurement accuracy ± 0.5 °C
Outflow
Measured value transmission – Sensor display content Current loop with “4 – 20 mA” for external display and control unit (option)
Measured value transmission – sensor PLC or main computer Analogue: “4 – 20 mA” active at 500 Ohm digital: Hart Modem, Modbus RTU
Valid measurement 3.75 mA to 21.6 mA (NAMUR)
Interface signal resolution 16 bit
Max. length of connecting cable 1000 m (depending on cable)
Power supply
Connection 24 V DC
15 V to 36 V DC
100 mA DC
Temperature
Medium temperature -5 °C to 80 °C (Standard)
-5 °C to 95° C (Option)
Ambient temperature -20 °C to 80 °C
Storage temperature -25 °C to 80 °C
Pressure
Pressure Flange for bolting on: -1 bar to 1 bar
Flange for welding on: -1 bar to 80 bar
Material
Housing material 1.4435 / 1.4571
Measuring field material/wearing protection Ceramic, ZrO2
Material of flange for bolting on/flange for welding on 1.4435 / 1.4571
Dimensions
Housing W/H 86 mm
120 mm
Cable length 2 m to 10 m

Voordelen

  • Indirect measuring method: Capacity determination in the high frequency stray field. This method uses the different dielectric constant (permittivity) of water and different materials (solids and liquids)
  • Fully reproducible sensors: If the plant is subsequently extended with sensors or if sensors are replaced, no recalibration is necessary thanks to the built-in microprocessor.
  • Process control and regulation: Thanks to extensive interfaces, the moisture measurement can be integrated into process control systems and controls.
  • Cost saving: Time-consuming and costly laboratory analyses are no longer necessary or can be reduced.
  • Temperature measurement/temperature compensation: The sensor can also be used to determine the temperature of the medium.
  • Limit values: Maximum or minimum limits can be set using the software. Light or sound signals can be triggered if required.
  • Mean value calculator: The sensor passes on already averaged values to the FMS evaluation and transfer module.
  • Compressive strength: The rod sensor withstands process pressures of up to 100 bar.
  • Sliding fitting: For cleaning, flushing or sensor replacement, the sliding fitting can be easily pulled out of the pipeline even under these circumstances without disturbing the process.

Accessories

  • Pressure sensor: The pressure sensor measures the pressure of the pipeline or tank system. (only on P45-GD rod sensor)
  • Flange: Use the flange to connect the sensor to the pipeline, tank system or bulk solid receptacle
  • Sliding fitting: With the sliding fitting you can mount the sensor on tank systems (rod sensor). The sliding fitting allows the sensor to be changed quickly without having to empty and depressurise the tank.
  • External display and control unit: The display and control unit is mounted up to 50 m away from the sensor in an easily accessible position. It is connected directly to the electronics of the sensor and powered by it.
  • Software: for start-up and configuration.

Brochure

Brochure Liebherr sensors

P78-E planar sensor data sheet (PDF, 183 KB)

Brochure Litronic WMSII Water Content Determination (PDF, 1.4 MB)