nCLD 84 M

ECO PHYSICS nCLD 84 M

Modular Gas Analyzer

The nCLD 84 M analyzer is the next generation in single-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 84 M is modular designed and capable of measuring NO or NOX. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.

7ECO PHYSICS nCLD 84 M  (Tagline: Modular Gas Analyzer)

The nCLD 84 M analyzer is the next generation in single-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 84 M is modular designed and capable of measuring NO or NOX. The new and intuitive graphical user interface “GUI“ also individually displays and connects to other instruments’ data.

Convenient and Highly Precise

The nCLD 84 M includes everything for measurement of NO or NOX. The fully revised detector-block, the enhanced gas flow paths and the improved pressure as well as temperature independence of the nCLD 800 Series instruments allow for even lower detection limits. Overall stability and reliability are lifted to a new level. The optional electro-mechanical bypass system balances out even fastest pressure variations occurring in the sample flow. Furthermore, the analyzer is adaptable to numerous non-standardized applications. The calibration of the unit runs quickly and automatically, with all necessary data available anywhere and at any time.

User Friendliness

The new touch sensitive graphical user interface enables the user to individually adjust the instrument operation and data management according to his/her needs and applications. The bright 7” monitor gives a clear overview and allows numerical and graphical display of values. Multiple digital in- and outputs guarantee a maximal connectivity and flexibility for the remote operation, control and maintenance of the nCLD 84 M.

Compact, Modular and Intelligent!

The nCLD 84 M is manufactured in a new compact and modular layout, in which each essential component of the chemiluminescence analyzer hosts its own CPU and interacts with other CPUs by BUS-communication. This assembly increases accessibility and serviceability by reducing wiring and piping. The measurement principle will conform to the standard method for NOX-detection in stationary source emissions (EN 15267).

Specificaties

Analyzer type single chamber CLD with cooled PMT for measurement of NO or NOX
Measuring ranges four freely selectable ranges from 0.5 ppm – 500 ppm
Min. detectable concentration* 0.012 ppm
Noise at zero point (1σ)* 0.006 ppm
Lag time <3 sec
Rise time (0-90%) <1 sec
Temperature range 5-40 °C
Humidity tolerance 5-95% rel. h (non-condensing, ambient air and sample gas)
Dry air use for O3 generator internally generated (no external supply gas required)
Sample flow rate 1.0 l/min
Input pressure 600 – 1’200 mbar abs.
Power required 350 VA (incl. membrane pump and scrubber)
Supply voltage 100-240 V/50-60 Hz
Interface USB(3x), HDMI, Bluetooth, RS232 (w/o 9pin connector), LAN, WLAN
Dimensions height: 133 mm (5¼”)

width: 450 mm (19”)

with molding: 495mm

depth: 540 mm (21.2”)

Weight 23 kg (51 lb)
Delivery includes nCLD 84 M analyzer, power cable, USB-LAN adapter
Standard nCLD 84 M: NO/NOX analyzer

· M – metal converter

Options · V1 – single calibration valve

· V2 – two calibration valves for pressurized calibration (zero & span / 2-3 bar)

· – hot tubing

· – electro-mechanical pressure regulation

· USB-RS232 9pin connector

· analog output (external box): 0-10 V ; 4-20 mA into 500 Ω max.

*Depending on filter setting.
Connectivity properties are country-specific.
ECO PHYSICS reserves the right to change these specifications without notice.