Closed loop relative humidity and temperature meter (hygrometer) for industrial use. The drawn current (4-20mA) responds to measured humidity 0-100% RH.The instrument uses a capacitance type sensing element with polymer dielectric medium. The temperature sensor is a Pt-1000 Ohm RTD. Microprocessor control allows for multipoint calibration. A maximum accuracy of 1.5 %RH is achieved with 8 points. Built in special temperature compensation is to correct humidity values from deviations arising from temperature effects on the sensor and the electronics. -
Optical Moisture Meter for Heat Treating Applications and Moisture in CO2 Applications. The XTDL-HT™ is designed with a new proprietary optical sampling system for the dirty blanket gases in your Heat Treating applications that causes other analyzers to be damaged, readings to drift and a measurement that cannot be trusted as reported by our many customers after 30 years in this business. -
The portable dew point meter, model XPDM, is a battery operated, hand-held, hygrometer, designed for applications where quick and accurate dew point measurements have to be made. Operating Principle The Xentaur dew point meter, XPDM utilizes HTFTM aluminum oxide sensors which adsorb water molecules much faster than they desorb water molecules. It is therefore an advantage, if at the beginning of the measurement the dew point sensor is dryer than the gas sample to be measured. The XPDM dew point meter keeps the sensor in dry storage until the measurement is taken. The sensor slides directly from the dry storage into the sample cell, without ever coming in contact with ambient air. After the measurement is completed, the sensor slides back into the dry storage, where it is dried down for the next sample. -
XDT in explosion proof enclosure, UL approved for use in Hazardous Locations Class I Division 1 Groups B, C & D.Xentaur Hyper-Thin-Film (HTF) AL2O3™ Moisture Sensor Technology The model XDT uses a Xentaur HTF™ Aluminum Oxide sensor. The breakthrough HTF™ sensor technology represents advances in thin film and metal oxide sciences and offers significant performance advantages over all other aluminum oxide sensors.The operating principle of the HTF™ aluminum oxide sensors is that a hygroscopic layer of aluminum oxide adsorbs or releases water molecules within its pores, depending on the water vapor pressure in its environment. The electrical capacitance of the aluminum oxide layer changes with the surrounding water vapor pressure. The electrical capacitance is measured between the aluminum core of the sensor and a porous conductive gold layer on the outside.The advantages of the HTF sensor technology are a result of the proprietary manufacturing method in which the aluminum oxide layer is made to be hyper thin as well as extremely hygroscopic. This results in a very sensitive sensor with fast response. -
The Xentaur digital dew point transmitters are designed as compact, simple and reliable instruments, which will continually monitor air dryer performance, compressed air quality and dry gas moisture, from ambient dew point levels to as low as -100ºC (-148ºF) up to +20ºC (+68ºF). Electronics The XDT transmitter electronics take full advantage of state of the art microprocessor technology and offer many advanced intelligent features. With optional dual alarms, analog and digital outputs, the Xentaur dewpoint transmitters can be used as indicators, alarm units or controllers. -
Xentaur’s Dew Point Meter, Model LPDT, is the world’s smallest loop powered (2-wire) dew point transmitter with a display. Electronics The compact LPDT dew point meter is a fully functional instrument operated through a miniature custom LCD display and three push buttons, using the same user friendly interface of all Xentaur hygrometers. The analog output is linear to the engineering units selected for display and is user configurable. A weatherproof cap is available for outdoor NEMA 4X (IP65) applications. -
Xentaur’s Dew Point Meter, Model HDT, is a rugged and unique loop powered dew point meter capable of both gas and liquid hydrocarbon phase measurements. The Model HDT Dew Point Meter uses a Xentaur HTF™ high capacitance aluminum oxide sensor with a measuring range of -100ºC to +20ºF or -60ºC to +20ºC. Customers can also request special ranges for special applications. The Xentaur dew point sensors provide a high degree of accuracy, speed, of response and stability unavailable from instruments using conventional aluminum oxide or polymer sensors. -
Transmitter for viscosity sensors
Maximum flexibility for optimum choice of measuring instrument: The VS-D250 and VS-4450 transmitters are compatible with all ViscoScope® sensors of types VA-100 and VA-300. Viscosity ranges are covered by the internal resolution of 16 bits over four decades (e.g. 1 - 10,000 or 10 - 100,000 etc.). Even for measurements with very small viscosity difference (example: milk and whey) the transmitters work precisely. Both transmitters VS-4450 and VS-D250 are equipped with a freely configurable display. The transmission of measurement and diagnostic data to a process control system is done via industry standard analog or digital interfaces. The VS-4450 is optionally available with 2 SPDT relays for time proportional control or alarms. The VS-D250 model is designed for DIN rail mounting.
-
The VS-4450 transmitter is compatible with all VA-100 and VA-300 ViscoScope® sensors and their predecessors. This ensures maximum flexibility when selecting the ideal instrument and replacing older transmitters. The internal resolution is 16 bits, which provides excellent coverage of viscosity ranges over 4 decades (e.g. 1 - 10,000 or 10 - 100,000 etc.). The transmitter can also be adjusted for measurements with a very low difference in viscosity (example: milk and whey). This model features a freely configurable display. Measurement and diagnostic data are transmitted to a process control system via analog or industry standard digital interfaces. The VS-4450 is available with 2 SPDT relays (optional) that provide time-proportional control or alarms. Built to the 19” standard, the transmitter is supplied in the control panel housing unless otherwise requested. However, other suitable housings, e.g. 19” rack, wall or Ex-d housings are possible.” -
Bepaalde toepassingen eisen op maat gemaakte sensoren. De VA-300 ViscoScope sensoren van Marimex kunnen worden ingezet om een technisch uitvoerbaar ontwerp te realiseren. Niet elke reactor heeft een vrije blokflens voor montage van een sensor. In vele gevallen is er slechts een nozzle beschikbaar. Dit resulteert in een dood volume dat evenwel kan worden overbrugd met een niet-actieve extensie (NAE). De diameter en lengte van de NAE zijn afgestemd op de afmetingen van de nozzle waardoor productophoping in het dode volume wordt voorkomen en de probe diep in de te meten vloeistof wordt gedompeld. Wanneer het toestel in een bocht geïnstalleerd wordt, kan de NAE worden aangepast aan de radius van de buis zodat de stroom niet wordt belemmerd. -
Inline Viscosity Sensor VA-100
The ViscoScope® sensors are made of high-quality, first-class stainless steel and impress with their intelligent, robust design. All parts in contact with the process are completely welded. Moving parts do not wear out and there are no leaks that damage the inside of the sensor housing. Inside each ViscoScope® viscometer is a Pt100 integrated into the sensor. The VA-100 sensor for viscosity measurement is manufactured as standard and is available with two probe versions in one temperature class and three different process connections.
-
Optimization of combustion efficiency and compliance with environmental standards Ideal for combustion control in boilers, incinerators and furnaces. Lowering CO₂, SOx, and NOx emissions while saving energy This oxygen analyser is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion management and control, such as garbage incinerators and smallest to largest sized boilers, as combustion controllers, achieving a significant energy-saving effect. -
Reliable process control for furnaces, metal industry, semiconductor and gas separation. The analyser continuously measures the concentration of gases such as H2, He, and Ar with high stability. It is also available in a version for hazardous areas (for countries outside the European Union): ZAFE certified Ex NEPSI. -
Ex-proof in situ zirconia oxygen analyzer for combustion controlThe oxygen measurement enables the control of burner fuel/air ratios to ensure combustion efficiency and process safety. Fuji Electric O2 Analyser is adapted to be installed in hazardous areas and to withstand critical environments as:- Refinery process heaters
- Petrochemical reactor furnaces
- Industrial large scale boilers