The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in a wide range of applications like all kind of emission control, catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air (immissions), solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy.
-
Methane only / Total Hydrocarbon THC monitoring system (Change-over switch) The 19” Flame-Ionisation-Detector (FID) 1230NMHC measures with its built-in NMHC-Cutter the methane concentration (methane only) and after switching to THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability.
-
19" rack version Flame-Ionisation Detector FID 1230
The Flame-Ionisation-Detector FID1230 Module measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy. Because of the module system, there is an optimal configuration for every measurement-task under profit aspects possible. All modules can be fit in at any time. -
High-Temperature Analyzer for Exhaust gas measurement
The flame-ionization-detector 1230I-H can measure the sum of total hydrocarbon concentrationin applications like cold starts of engines (down to–40°Cambient temperature), inwoodburning systems and also at engine test units (especially oil-and gasburners, airplaneengines etc.) Our high temperature heated lines with a operation temperature of 400°C are made additionally for measurements of highboiling hydrocarbons. For the sample-gas pickup we have built some prefilters who are able to hold back the tar compounds. -
- real-time measurement of PM2,5
- Monitoring of fine dust concentrations in ambient air and/or at workplaces
- optical sensor including fitting with clip system, therefore easily exchangeable
- active and automatic zero point setting
- active air suction
- Integrated pre-separator for particles > 2,5 µm
- noiseless operation
- network-compatible
-
Fuji Electric Extractive Gas Analyzers for process control and continuous measurement of stack emissions. Their QAL1 certification guarantees high performance and regulatory and normative compliance. Reliable and precise, their design quality guarantees 24-hour operation in difficult environments such as smoke from industrial chimneys. Robustness reduces maintenance costs and increases the availability of boilers and equipment. Extractive measurement consists of taking a gas flow from the chimney or the gas pipe via a sampling probe and conveying it to the gas analyzer. The gas is sampled, treated in order to ensure optimal conditions for gas measurement.
-
Due to various acid dew points at various applications the probe is heated up to 180°C.
A filter element of 150mm is integrated, suitable for most applications up to 1g dust/m3. A significant advantage is that this filter is replaceable without dismounting the probe. With the filter element of 150mm length this probe is suitable for most applications up to 1g dust/m3; with the blow-back function dust loads of up to 10g/m3 can be handled.
Calibration gas can be injected directly into the probe through the calibration gas connection according to EN14181 (regulation for calibration of emission monitoring systems) that enables calibration gas feeding via the filter element of the gas sample probe. The use of the optional high-flow check valve type APP 200 is recommended.
The portable gas sample probe series APP is a perfect completion to the Ankersmid portable gas conditioning system series APS 303/313. Both devices can easily be connected together by the Ankersmid heated sample line type AHL205/025 with the incorporated innovative Quick-Lock System which guarantees a fast and reliable connection.
Using this heated line the probe's electrical power is then fed to the probe via the feed line integrated within the sample line. To avoid cooling-down and condensation of sample gas in the extraction area, the heated sample probe tube type AST 301 is available.
-
The portable system is suitable for variable, discontinuous and continuous operation. The components built into the system can be used for standard applications. For special requirements please ask us for other solutions.
The heated sample line is to be mounted at the gas measuring inlet terminal inside the portable case. A ball-valve can be fitted to the inlet terminal of the portable system in order to calibrate analyser(s) with check gas.
The amount of flow is determined by a sample gas diaphragm pump. The sample gas pump AMP 11P is activated automatically by means of an excess temperature contact on the cooler.
Optional flow meters with integrated needle valve are available. The flow meters are built-in as the electronic controller and are visible from outside when the carrying case is closed. This unique microprocessor controlled Peltier cooler is a powerful designed dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1°C and 15°C. The gas cooler is equipped with an innovative heat exchanger system.
-
SupremeLine Trace Gas Analyzer With CraNOx II, ECO PHYSICS is launching the second generation of its high-end measurement solution in the ppb and ppt range. The new system is smaller and more sophisticated, as it now has the power to calculate the photostatic equilibrium by means of the integrated ozone analyzer. The CraNOx II system is capable of simultaneously measuring NO, NOX, NO2 and O3. Furthermore, it can be expanded to assess NOY and NH3 concentrations.
-
The heated prefilter model iFiD Filter Backwash M1is a samplegasfilter which can flushbacked with an electronic solenoid valve. This valve can controll the pressure air (flushbackair) and the sample gas. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
-
The heated sampling system is a combination of a heated sample line and a heated sample filter. The sample line is 500mm long; the filter element can be replaced very quick with the bayonet lock. Beside the very precisious and constant regulation of the line and filter temperature, there is a separate controll point fort he temperature at the filterinlet, where you have an information of the exhaust gas temperature. Also the calibration gas (prewarmed) can directly connected with the unit. The thermocouple is available as PT 100 or NiCrNi.
-
atmosFIR is the latest generation of gas analyser technology from Protea. The atmosFIR system improves upon previous FTIR technology and represents one of the most cost-effective and flexible analytical products on the market today. atmosFIRw has been designed to give a complete measurement system with embedded touchscreen controller. At the heart of atmosFIRw is a high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIRw has been developed to incorporate the latest improvements and advantages in technology, including:
- Low cost of ownership and maintenance
- Robust and light, including the latest in fabrication materials
- atmosFIR combines an FTIR analyser with an in-built sampling system and embedded PC controller for a complete system
-
atmosFIRt is the latest generation of FTIR gas analyser technology from Protea in a portable or mobile form. The atmosFIR system improves upon previous FTIR technology and represents one of the most cost-effective and flexible analytical products on the market today. At the heart of atmosFIR is a high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIR has been developed to incorporate the latest improvements and advantages in technology.
-
atmosFIR CEM is a complete emissions monitoring system incorporating the atmosFIR 19” FTIR analyser. As completely hot and wet emissions measurement, atmosFIR CEM is ideal for complete measurement of multiple gases from applications such as incineration and power. A standard gas suite of NO, NO2, N2O, SO2, NH3, HCl, CH4, O2, CO2 and H2O is provided, but with the powerful FTIR analyser, further gases can be added easily in software. At the heart of system is the high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIR has been developed to incorporate the latest improvements and advantages in technology, The atmosFIR FTIR analyser contains an in-built sampling system and is designed for ppm-level emissions monitoring. The analyser can be used as a portable or bench-top unit as well as part of the installed CEM system.
-
atmosFIR is the successor to Protea's previous emissions monitoring FTIR systems, keeping all the features that users found valuable in achieving their measurement results, but offering the benefits of the new atmosFIR platform with increased portability, lower ownership costs and increased measurement performance. atmosFIR can be considered a simple multi-gas analyser for combustion gas measurements; indeed for some users that is all it will be and as such it provides a cost-effective and complete measurement system. However, for the expert user atmosFIR will offer all the benefits of FTIR, with hundreds of gas measurements, multiple analytical ranges, in-depth chemometric result diagnoses and dedicated on-board sampling system. With Protea's in-house chemometrics application support and 15+ year history of emission monitoring projects, atmosFIR offers the user the complete package for their monitoring needs. With long-lifetime VCSEL reference laser diode, unique cell design, and air cooled DTGS detector with 24-bit ADC, atmosFIR is a step-change in value and service lifetime for FTIR emission gas analysis.
-
Ex-proof in situ zirconia oxygen analyzer for combustion controlThe oxygen measurement enables the control of burner fuel/air ratios to ensure combustion efficiency and process safety. Fuji Electric O2 Analyser is adapted to be installed in hazardous areas and to withstand critical environments as:
- Refinery process heaters
- Petrochemical reactor furnaces
- Industrial large scale boilers
-
The air purifier CAP 15 and air purifier CAP 30 produces clean and hydrocarbon-free air out of normal compressed air. The Pt/Pd-catalyst convert by catalytical total-oxidation at 370°C all hydrocarbons inclusive methane (CH4) into carbondioxyde (CO2) and water (H2O). Hydrogen (H2) and carbonmonoxyde (CO) will be removed quantitatively.The produced air quality ist constantly free of hydrocarbons and better than sythetic air from gas bottles of class 5.0 (refering to organic components).On account of the high gas purity, the air purifier CAP 15/30 are used for FID-measuring systems as combustion air and as zero gas
-
De zeer nauwkeurige draagbare zuurstofanalysatoren van Analytical Industries zijn bedoeld voor toepassingen die op verschillende gedefinieerde meetpunten moeten worden gecontroleerd. Het GPR-3500-model heeft een compacte, robuuste behuizing en bevat roestvrijstalen onderdelen die in contact komen met de vloeistof, geïntegreerde debietmeters en naaldventielen. Het meet de zuiverheid voor inerte gassen, kooldioxide en zuurstof. De GPR-1200 compacte draagbare zuurstofanalyser voor sporen heeft een 4-wegklep die een gasmonster in de sensor opvangt. Dit maakt snellere zuurstofmeettijden mogelijk bij het verplaatsen van punt naar punt in een proces en beschermt ook sporenzuurstofsensoren tegen voortijdige uitputting als gevolg van blootstelling aan omgevingszuurstofniveaus om hun levensduur te verlengen. Dit alles zorgt voor een zuinige werking en lage eigendomskosten voor deze toonaangevende reeks draagbare zuurstofanalysers.