nCLD 822 M

ECO PHYSICS nCLD 822 M

Modular Gas Analyzer

The nCLD 822 M analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 M is modular designed and capable of simultaneously measuring NO, NO2 and NOX. The analyzer’s expandable capabilities allow assessment of hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.

nCLD – A New Generation
The nCLD 822 M includes everything for measurement of NO, NO2 and NOX. The fully revised detector-block, the enhanced gas flow paths and the improved pressure as well as temperature independence of the nCLD 800 Series instruments allow for even lower detection limits. Overall stability and reliability are lifted to a new level. The optional electro-mechanical bypass system balances out even fastest pressure variations occurring in the sample flow. Furthermore, the analyzer is adaptable to numerous non-standardized applications. The calibration of the unit runs quickly and automatically, with all necessary data available anywhere and at any time.

User Friendliness
The new touch sensitive graphical user interface enables the user to individually adjust the instrument operation and data management according to his/ her needs and applications. Multiple digital in- and outputs guarantee a maximal connectivity for your remote operation, control and maintenance of the nCLD 822 M, ensuring unsurpassed precision and reliability while all necessary data is readily available anywhere and at any time.

Compact, Modular and Intelligent!
The nCLD 822 M is manufactured in a new compact and modular layout, in which each essential component of the chemiluminescence analyzer hosts its own CPU and interacts with other CPUs by BUS-communication. This assembly increases accessibility and serviceability by reducing wiring and piping. The measurement principle will conform to the standard method for NOX-detection in stationary source emissions (EN 15267).

Specificaties

Analyzer type dual chamber CLD with cooled PMT for measurement of NO, NO2 and NOX
Measuring ranges four freely selectable ranges from 5 ppm – 5000 ppm
Min. detectable concentration* 0.12 ppm
Noise at zero point (1σ)* 0.06 ppm
Lag time <3 sec
Rise time (0-90%) <1 sec
Temperature range 5-40 °C
Humidity tolerance 5-95% rel. h (non-condensing, ambient air and sample gas)
Dry air use for O3 generator internally generated (no external supply gas required)
Sample flow rate 1.0 l/min
Input pressure 600 – 1’200 mbar abs.
Power required 350 VA (incl. membrane pump and scrubber)
Supply voltage 100-240 V/50-60 Hz
Interface USB(3x), HDMI, Bluetooth, RS232 (w/o 9pin connector), LAN, WLAN
Dimensions height: 133 mm (5¼”)

width: 450 mm (19”)

with molding: 495mm

depth: 540 mm (21.2”)

Weight 23 kg (51 lb)
Delivery includes nCLD 822 M analyzer, power cable, USB-LAN adapter
Standard nCLD 822 M: NO, NO2, NOX analyzer

· M – metal converter

Options · V1 – single calibration valve

· V2 – two calibration valves for pressurized calibration (zero & span / 2-3 bar)

· – hot tubing

· – electro-mechanical pressure regulation

· USB-RS232 9pin connector

· analog output (external box): 0-10 V ; 4-20 mA into 500 Ω max.

*Depending on filter setting.
Connectivity properties are country-specific.
ECO PHYSICS reserves the right to change these specifications without notice.

Brochure

Further information can be found in the Product Brochure

Download Brochure

VRAAG EEN OFFERTE