nCLD 844 Mh
Modular Gas Analyzer
The nCLD 844 Mh analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 Mh is modular designed and capable of simultaneously measuring NO, NO2 and NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
nCLD – A New Generation
The nCLD 844 Mh includes everything that is needed for measuring NO, NO2 and NOX in unpreconditioned gas samples. The fully revised detector-block, the enhanced gas flow paths and the improved pressure as well as temperature independence of the nCLD 800 Series instruments allow for even lower detection limits. Overall stability and reliability are lifted to a new level. The integrated hot tubing enables the instrument to analyze hot and moist sources without external gas preconditioning unit, allowing highly precise analysis. The calibration of the unit runs quickly and automatically, with all necessary data stored and available anywhere and at any time.
User Friendliness
The new touch sensitive graphical user interface enables the user to individually adjust the instrument operation and data management according to his/ her needs and applications. The bright 7” monitor gives a clear overview and allows numerical and graphical display of values. Multiple digital in- and outputs guarantee a maximal connectivity for your remote operation, control and maintenance of the nCLD 844 Mh, ensuring unsurpassed precision and reliability.
Compact, Modular and Intelligent!
The nCLD 844 Mh is manufactured in a new compact and modular layout, in which each essential component of the chemiluminescence analyzer hosts its own CPU and interacts with other CPUs by BUS-communication. This assembly increases accessibility and serviceability by reducing wiring and piping. The measurement principle will conform to the standard method for NOx-detection in stationary source emissions (EN 15267).
Specificaties
Analyzer type | dual chamber CLD with cooled PMT for measurement of NO, NO2 and NOX |
Measuring ranges | four freely selectable ranges from 0,5 ppm – 500 ppm |
Min. detectable concentration* | 0.012 ppm |
Noise at zero point (1σ)* | 0.006 ppm |
Lag time | <3 sec |
Rise time (0-90%) | <1 sec |
Temperature range | 0-40 °C |
Humidity tolerance | 5-95% rel. h (non-condensing, ambient air and sample gas) |
Dry air use for O3 generator | internally generated (no external supply gas required) |
Sample flow rate | 1.0 l/min |
Input pressure | 600 – 1’200 mbar abs. |
Power required | 350 VA (incl. membrane pump and scrubber) |
Supply voltage | 100-240 V/50-60 Hz |
Interface | USB(3x), HDMI, Bluetooth, RS232 (w/o 9pin connector), LAN, WLAN |
Dimensions | height: 133 mm (5¼”)
width: 450 mm (19”) with molding: 495mm depth: 540 mm (21.2”) |
Weight | 23 kg (51 lb) |
Delivery includes | nCLD 844 Mh analyzer, power cable, USB-LAN adapter |
Standard | nCLD 844 Mh: NO, NO2, NOX analyzer
· M – metal converter · h – hot tubing |
Options | · V1 – single calibration valve
· V2 – two calibration valves for pressurized calibration (zero & span / 2-3 bar) · r – electro-mechanical pressure regulation · USB-RS232 9pin connector · analog output (external box): 0-10 V ; 4-20 mA into 500 Ω max. |
*Depending on filter setting. | |
Connectivity properties are country-specific. | |
ECO PHYSICS reserves the right to change these specifications without notice. |