Protea 2000

“P2000 is an infra-red (IR), duct or stack-mounted Analyser, designed to provide In-Situ analysis of up to six gas-phase emission components such as CO, CO2, SO2, NO, NO2 and many more.

A typical system comprises of a stack mounted Analyser, an integral Calibration Module and a Control Unit with options which include a powerful In-Situ Heater and a stand-alone Analysis Software package.

 

Categories: , ,

P2000 uses the reflective beam principal to directly measure process gas as it enters the in situ sample cell.

Unlike higher maintenance extractive systems, Protea’s patented, sintered metal technology removes the need for gas filtering or sample conditioning.

The P2000 analyser requires very little maintenance and achieves a class-beating availability of over 98% in demanding applications.

The Control Unit can support multiple analysers from the Protea range.

Principles of Operation

Analyser: The P2000 analyser operates on the proven, single beam, dual–wavelength IR principle. Mid IR Pulses, at two specific wavelengths per monitored component, are transmitted through the sample cell. The ‘measure’ pulse is partially absorbed by the gases being measured while the ‘reference’ pulse remains unaffected.

Up to eight wavelengths are available, sometimes sharing reference wavelengths, allowing up to six gas-phase component concentrations to be monitored simultaneously. Uniquely, the operation, zero and calibration are “fully challenged” in that all operating modes use the same optical path and system components.

Auto Verification: The integral Auto Verification Unit provides a zero-check on the system by filling the sample probe with clean, dry instrument air. Similarly, it performs a span-check by filling the sample probe with certified span gas.

Controller

In-Situ CEMs Control Unit

In addition to collecting data from Protea’s P2000 and P5000 analysers, it is configured to receive data from complementary devices, e.g. Dust / Opacity, Oxygen and Flow. This enables the system to display gas concentrations on a normalised basis and, if required, in mass units e.g. Kg/hour. The analyser communicates via a serial data link to the control unit, which can be located up to 1200m from the CEMS. Intuitive software is designed to utilise either a pointing device or touch screen for all operator functions. The Protea S-PC is capable of supporting up to six Protea Analysers with associated third party devices.

Features

  • Multi-component gas analysis
  • Direct in-situ measurements
  • Wet or dry readings
  • Automatic signal verification and recalibration
  • Oxygen or CO2 measurement normalisation (option)
  • Single Flange mounted analyser
  • Low maintenance
  • ATEX / IEC option
  • ABS approved
  • Marine approved
  • MCERTS approval

 

Benefits

 

  • Each P2000 can measure up to six components
  • No requirement for high cost, high maintenance sample handling system or sample conditioning
  • Can inherently report on Wet or Dry gas basis
  • No operator intervention during routine use
  • Report measurement corrected to normalised O2 or CO2 reference conditions
  • Reduced cost and simplicity of installation
  • Reduced cost of ownership
  • Can be used in hazardous areas
  • Suitable for marine applications”

Gassen

Gassen en meetbereiken

PRO025 A4 Range Sheet_v3 thumb

Brochure

Certificaten

MCERTS LogoCertification with environmental monitoring equipment standards is dependent on analyser series and application.

Certification of models includes EN 15267-3 MCERTS; EN 14181 QAL 1 and US EPA 40cfr part 60 & 75.

 

MCERTS LogoMCERTS LogoMCERTS Logo

Certified for use in Hazardous Areas Option.

VRAAG EEN OFFERTE