• Aurora 1030D

    TOC Analyzer
    Experience two types of TOC analysis in one powerful instrument! Use the Aurora 1030D to analyze TOC through the proven heated persulfate wet oxidation technique or the high temperature combustion method. Both modes have distinct chamber features to ensure accurate and reliable results.  
  • Aurora 1030W

    TOC Analyzer
    The Aurora 1030 line of TOC analyzers from OI Analytical includes instrument configurations for laboratory and process monitoring, employing 100 °C persulfate wet oxidation or thermal combustion techniques. The Aurora 1030 line incorporates several noteworthy innovations and can be equipped with parallel reactors allowing concurrent sample processing for increased analytical throughput. The unique 1030D Dual Mode TOC analyzer allows sample processing by wet oxidation or thermal combustion using the same instrument.
  • Automatic calibration unit

    Automatic calibration system for the Mercury Ultratracer UT-3000
    The static calibration unit is meant for automatically calibrating the UT-3000 Mercury Ultratracer in natural gas monitoring systems for low to intermediate mercury concentrations.
  • De Kjeldahl-methode is een methode geschikt om de fractie organische stikstof in samples te bepalen. De methode zal de hoeveelheid stikstof en ammoniak die in organische verbindingen vervat zit analyseren, enkel stikstof in de vorm van nitraten en nitrieten verbindingen worden genegeerd.

    Deze erg oude methode is nog steeds de meest “populaire” (lees erkende) methode voor het bepalen van Stikstof in waters en voedsel samples.

    Omwille van de chemicaliën en de hogere temperaturen die zich in het Kjeldahl proces voordoen is Kjeldahl lang een ongewenste gast op het labo geweest daar de nodige voorzichtigheid aangewezen is.

    Vandaag zijn deze analyses bijna volledig geautomatiseerd, beveiligd en gecontroleerd zodat het gebruik van deze analyzers haast kinderspel geworden is.

  • Automatic sampler robot

    Automatische air-displacement vloeistof sampler

    Het  VERSA 10  werkstation is  een  compacte,  kost effectieve,  high throughput, automatische  air-displacement  vloeistof sampler.

    Het  systeem bied een oplossing voor de nood aan hoge doorvoer vloeistof behandelings mogelijkheden van een klein benchtop model tot een uitgebreid vloer model. Door het combineren van een 4 of 8 kanaals kop maar wel met single kanaals functionaliteit kan dit workstation de routine protocollen automatiseren met een variabele hoeveelheid aan samples. Het compacte 6positie werkplatform zorgt ervoor dat u de pipetteer protocollen kunt uitvoeren in een bio-afzuigkap of plekken met beperkte ruimte.

    Dit systeem ondersteund verschillende eigen reagentia en labware door zijn open systeem en dit aan een zeer aantrekkelijke prijs.

  • The heated sampling system is a combination of a heated sample line and a heated sample filter. The sample line is 500mm long; the filter element can be replaced very quick with the bayonet lock. Beside the very precisious and constant regulation of the line and filter temperature, there is a separate controll point fort he temperature at the filterinlet, where you have an information of the exhaust gas temperature. Also the calibration gas (prewarmed) can directly connected with the unit. The thermocouple is available as PT 100 or NiCrNi.
  • Backscatter probes

    0.0005% (10 NTU) to 100% solids
    Kemtrak backscatter probes are designed to accurately measure low to extremely high turbidity directly in tanks and pipelines. The dual fiber optic design of the Kemtrak probe provides high resolution at low turbidity ranges with excellent linearity all the way up to extremely high turbidities when used with a Kemtrak NBP007 backscatter photometer. A unique benefit of the Kemtrak backscatter immersion probe is that it does not go blind at high sample turbidities. Other probes stop working at 4 000 NTU/FNU (< 1 wt% solids) after which the signal will decrease resulting in an erroneous and misleading output. The output of the Kemtrak probe will continue to increase with sample concentration ensuring a reliable measurement.  
  • Backwash M1

    Filter Model iFiD
    The heated prefilter model iFiD Filter Backwash M1is a samplegasfilter which can flushbacked with an electronic solenoid valve. This valve can controll the pressure air (flushbackair) and the sample gas. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Backwash M2

    Filter iFiD
    The heated prefilter model iFiD Backwash M2 is a samplegasfilter which can be flushbacked. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Calibrator MC-3000

    Mercury calibration gas generator
    The MC-3000 is used for generating a continuous stream of a mercury vapor loaded gas stream in order to check or calibrate mercury analyzers. It is also suitable for all those applications where a gas stream with a preset and constant mercury concentration is needed.
    • Generates elemental mercury vapor
    • continuous operation
    • approx. 10 ... 500 µg/m³ Hg°
    • Compact and portable size
    • No permeation principle - no need to calibrate the calibrator
    • Microprocessor controlled
  • Chip-DSC 1

    Patented, revolutionary Sensor Concept

    The all new Chip-DSC 1 integrates all essential parts of DSC: furnace, sensor and electronics in a miniaturized housing. The chip-arrangement comprises the heater and temperature sensor in a chemically inert ceramic arrangement with metallic heater and temperature sensor. This arrangement allows superior reproducibility and due to the low mass outstanding temperature control and heating rates of up to 100 K/min. The integrated sensor is easily user exchangeable and available for a low cost. The integrated design of the chip-sensor delivers superior raw data, which enables a direct analysis without pre- or post-processing of heat flow data. The compact construction, leads to a significant reduction in production cost which can be passed on to our customers. The low energy consumption and unrivaled dynamic response result in unsurpassed performance of this revolutionary DSC-concept.
  • Chip-DSC 10

    Revolutionary Sensor Concept

    The all new Chip-DSC 10 integrates all essential parts of DSC: furnace, sensor and electronics in a miniaturized housing. The chip-arrangement comprises the heater and temperature sensor in a chemically inert ceramic arrangement with metallic heater and temperature sensor. This arrangement allows superior reproducibility and due to the low mass outstanding temperature control and heating rates of up to 300 K/min. The integrated sensor is easily user exchangeable and available for a low cost. https://www.youtube.com/watch?v=07XKWG_aEoc  
  • Chip-DSC 100

    Revolutionary Sensor Concept

    The Chip-DSC 100 combines the advantages of chip technology with the requirements of our previous DSC models. Various options such as a sample robot, UV attachment and Raman spectroscopy transform the Chip-DSC 100 into a highly versatile measuring instrument. The arrangement of the Chip-Sensor allows superior reproducibility and due to the low mass outstanding temperature control and heating rates of up to 1000 K/min. The integrated sensor is easily user exchangeable and available for a low cost. The integrated design of the chip-sensor delivers superior raw data, which enables a direct analysis without pre- or post-processing of heat flow data. Applications on the Chip-DSC 100 can be expanded with various accessories. You can use different cooling systems in combination with a sample robot. The sample robot is available with 96 positions.
  • Compressorkoeler type ACC

    voor tot 4 maximum gasstromen

    The ACC cooler offers precision, safety and long-term stability for extractive analytics. The very low gas dissolution rate is attained owing to the new cooler technology (Patents applied). Both the permanent separation of the condensate from the gas phase, as well as the shorter contact time of the gas in the system, plays important roles in reducing gas dissolution rates.

    The new cooler incorporates an advanced structural design with housing suitable for both wall-mounting and 19“-racks. The coolers can be integrated into the analysis cabinet without empty space requirements at the side for a cooling air outlet.

    The new design enables up to 4 heat exchangers and peristaltic pumps to be incorporated either at the factory or at a later time, without any problem. The exchangers and pumps can be connected in series or parallel following customer requirements.

    An electronic system not only monitors the dew point, but also the ambient temperature. The integrated fan is cooling air temperature dependent controlled.

    A temperature alarm output is wired to the terminal block incorporated of the cooler housing for a safe connection without disassembling the cooler.

    Available for 230VAC and 115VAC power supply.

  • CraNOx II

    NO, NO₂, NOₓ, O₃ - 1 ppb – 1’000 ppb
    SupremeLine Trace Gas Analyzer With CraNOx II, ECO PHYSICS is launching the second generation of its high-end measurement solution in the ppb and ppt range. The new system is smaller and more sophisticated, as it now has the power to calculate the photostatic equilibrium by means of the integrated ozone analyzer. The CraNOx II system is capable of simultaneously measuring NO, NOX, NO2 and O3. Furthermore, it can be expanded to assess NOY and NH3 concentrations.
  • DCP007 NIR Photometer

    for concentration and trace water measurements
    The Kemtrak DCP007-NIR is an advanced dual wavelength NIR photometer designed to accurately measure the concentration of process liquids and gasses with near-infrared (NIR) absorbance between 800 and 1550 nm. Examples of NIR measurements include moisture (water & trace water), ethanol, methanol, sodium hydroxide, ammonia and continuous fuel identification. The Kemtrak DCP007-NIR uses a long life high performance NIR LED light source with robust industrial grade fiber optics to deliver a drift and noise-free measurement with very high precision. Automatic compensation for sample turbidity and/or fouling of the optical windows ensures trouble free operation.

Titel