• Automatic calibration unit

    Automatic calibration system for the Mercury Ultratracer UT-3000
    The static calibration unit is meant for automatically calibrating the UT-3000 Mercury Ultratracer in natural gas monitoring systems for low to intermediate mercury concentrations.
  • Calibrator MC-3000

    Mercury calibration gas generator
    The MC-3000 is used for generating a continuous stream of a mercury vapor loaded gas stream in order to check or calibrate mercury analyzers. It is also suitable for all those applications where a gas stream with a preset and constant mercury concentration is needed.
    • Generates elemental mercury vapor
    • continuous operation
    • approx. 10 ... 500 µg/m³ Hg°
    • Compact and portable size
    • No permeation principle - no need to calibrate the calibrator
    • Microprocessor controlled
  • The heated sampling system is a combination of a heated sample line and a heated sample filter. The sample line is 500mm long; the filter element can be replaced very quick with the bayonet lock. Beside the very precisious and constant regulation of the line and filter temperature, there is a separate controll point fort he temperature at the filterinlet, where you have an information of the exhaust gas temperature. Also the calibration gas (prewarmed) can directly connected with the unit. The thermocouple is available as PT 100 or NiCrNi.
  • Heated Inlet Protection Filter model number 1035 is made for filtering the particles from a size of 5μ and bigger out of the samplegas. The Operation time of an Testa-FID without a build in filter (Model 123) can lengthened several times, because this fine filter helps to minimize the change of the sample capillary, the cleaning of the pump and minimize the maintenance. All the spikes you can see without filter are eliminated with our model 1035.
  • Heated solenoid valve

    for SHED chamber

    Modell iFiD SHED

    The heated solenoid-valve prevents dilution or increase of the measurement gas concentration by giving up zero gas as well as test gas during or before the shed test measurement.
  • The heated 3-way solenoid valve is made for switching 2 heated lines on one analyzer. Beside this there is a second outlet for IR-analyzers or other analyzers built in.
  • The filterinlet model iFiD Filter is a flashbackable filterunit for all heated Testa Samplegasfilters. The filter is usable for exhaust gas from engines as well as for emmission measuring tasks.
  • Backwash M2

    Filter iFiD
    The heated prefilter model iFiD Backwash M2 is a samplegasfilter which can be flushbacked. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Backwash M1

    Filter Model iFiD
    The heated prefilter model iFiD Filter Backwash M1is a samplegasfilter which can flushbacked with an electronic solenoid valve. This valve can controll the pressure air (flushbackair) and the sample gas. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Heated Prefilter

    Model iFiD Filter XL
    The heated prefilter model iFiD FIlter XL is a samplegasfilter for the high temperature applications with a permanent temperature of 300°C. The filter is very stable with the temperature level you preselect, and also in permanent operation. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of + 1%.
  • The heated prefilter model iFiD Filter is a gasfilter for the high temperature applications who need a permanent temperature up to 300°C. The filter is very stable with the temperature level you can preselected. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of +-1%.
  • The gasstation is fitted with all supplygases who are necessary for a FID measurement. Hydrogen as the fuel gas, nitrogen as zerogas and propane as the calibration gas are available in the one liter bottles who allows a very good handling in mobile measurement. The FID can be connected via teflon hoses and quick connectors.
  • The heated transferline is made of a stainless steal tube with soldered heater. This construction is unique in relation to other lines and is guarantee for a very good heattransfer. Especially in cases of alternating process temperatures, the sample temperature can stabilized at preselected level. A Low-Cost-Version is available with simple teflon hose.
  • The air purifier CAP 15 and air purifier CAP 30 produces clean and hydrocarbon-free air out of normal compressed air. The Pt/Pd-catalyst convert by catalytical total-oxidation at 370°C all hydrocarbons inclusive methane (CH4) into carbondioxyde (CO2) and water (H2O). Hydrogen (H2) and carbonmonoxyde (CO) will be removed quantitatively.The produced air quality ist constantly free of hydrocarbons and better than sythetic air from gas bottles of class 5.0 (refering to organic components).On account of the high gas purity, the air purifier CAP 15/30 are used for FID-measuring systems as combustion air and as zero gas
  • The air purifier CAP 15 and CAP 30 produces clean and hydrocarbon-free air out of normal compressed air. The Pt/Pd-catalyst convert by catalytical total-oxidation at 370°C all hydrocarbons inclusive methane (CH4) into carbondioxyde (CO2) and water (H2O). Hydrogen (H2) and carbonmonoxyde (CO) will be removed quantitatively.The produced air quality ist constantly free of hydrocarbons and better than sythetic air from gas bottles of class 5.0 (refering to organic components).On account of the high gas purity, the air purifier CAP 15/30 are used for FID-measuring systems as combustion air and as zero gas.
  • Litronic FMS IV

    Evaluation and transfer module PROFINET
    A self-sufficient moisture measuring installation with high connectivity and many interesting possibilities. With ProfiNet technology on board, extensive signal processing and WEB-based access, we are ready for Industry 4.0. Without Ethernet support, these tasks cannot be accomplished. At the beginning of each measured section, the calibration per product must be carried out by means of reference procedures. The Litronic-FMS IV software enables convenient and rapid parametrisation. The evaluation unit receives the raw values measured by the Liebherr sensors and immediately converts them into the measured value, such as percentage humidity. Up to 16 sensors can be managed via the WEB with one device. A curve manager and material and sample management helps the user to create the product-specific calibration. Once the system has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age. In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility. A sensor exchange or a transfer to another measured section is also possible without recalibration.