• The VS-4450 transmitter is compatible with all VA-100 and VA-300 ViscoScope® sensors and their predecessors. This ensures maximum flexibility when selecting the ideal instrument and replacing older transmitters. The internal resolution is 16 bits, which provides excellent coverage of viscosity ranges over 4 decades (e.g. 1 - 10,000 or 10 - 100,000 etc.). The transmitter can also be adjusted for measurements with a very low difference in viscosity (example: milk and whey). This model features a freely configurable display. Measurement and diagnostic data are transmitted to a process control system via analog or industry standard digital interfaces. The VS-4450 is available with 2 SPDT relays (optional) that provide time-proportional control or alarms. Built to the 19” standard, the transmitter is supplied in the control panel housing unless otherwise requested. However, other suitable housings, e.g. 19” rack, wall or Ex-d housings are possible.”
  • Bepaalde toepassingen eisen op maat gemaakte sensoren. De VA-300 ViscoScope sensoren van Marimex kunnen worden ingezet om een technisch uitvoerbaar ontwerp te realiseren. Niet elke reactor heeft een vrije blokflens voor montage van een sensor. In vele gevallen is er slechts een nozzle beschikbaar. Dit resulteert in een dood volume dat evenwel kan worden overbrugd met een niet-actieve extensie (NAE). De diameter en lengte van de NAE zijn afgestemd op de afmetingen van de nozzle waardoor productophoping in het dode volume wordt voorkomen en de probe diep in de te meten vloeistof wordt gedompeld. Wanneer het toestel in een bocht geïnstalleerd wordt, kan de NAE worden aangepast aan de radius van de buis zodat de stroom niet wordt belemmerd.
  • ViscoScope VA-100

    procestemperaturen tot 130°C

    Inline Viscosity Sensor VA-100

    The ViscoScope® sensors are made of high-quality, first-class stainless steel and impress with their intelligent, robust design. All parts in contact with the process are completely welded. Moving parts do not wear out and there are no leaks that damage the inside of the sensor housing. Inside each ViscoScope® viscometer is a Pt100 integrated into the sensor. The VA-100 sensor for viscosity measurement is manufactured as standard and is available with two probe versions in one temperature class and three different process connections.

  • In-situ zirconia oxygen gas analysers

    Fast response (4–7 seconds)
    Optimization of combustion efficiency and compliance with environmental standards Ideal for combustion control in boilers, incinerators and furnaces. Lowering CO₂, SOx, and NOx emissions while saving energy This oxygen analyser is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion management and control, such as garbage incinerators and smallest to largest sized boilers, as combustion controllers, achieving a significant energy-saving effect.
  • Hydrogen Analysers

    Thermal Conductivity Gas Analyser ZAF and ZAFE
    Reliable process control for furnaces, metal industry, semiconductor and gas separation. The analyser continuously measures the concentration of gases such as H2, He, and Ar with high stability. It is also available in a version for hazardous areas (for countries outside the European Union): ZAFE certified Ex NEPSI.
  • ATEX in-situ oxygen analysers

    Ex-proof in situ zirconia oxygen analyzer for combustion control
    Ex-proof in situ zirconia oxygen analyzer for combustion control
    The oxygen measurement enables the control of burner fuel/air ratios to ensure combustion efficiency and process safety. Fuji Electric O2 Analyser is adapted to be installed in hazardous areas and to withstand critical environments as:
    • Refinery process heaters
    • Petrochemical reactor furnaces
    • Industrial large scale boilers
  • ZRE

    5 gas NDIR analyser - Single beam
    Compact and easy to use Excellent stability over time No influence of humidity on the measurement Automatic calibration, communication and alarms Simultaneous and continuous measurement of the concentration of 5 gases: CO - CO2 - NO - NOX - SO2 - CH4 - O2
  • ZKJ

    5 components analyser - NDIR dual beam

    Ideal for controlling polluting emissions

    Uses a highly sensitive mass flow meter as a detector. Simultaneous and continuous measurement of 5 gases : CO2  -  CO  -  CH4  -  NOX  -  SO2  -  O2  -  NO  -  N2O
  • Dilatometer DIL

    from -180°C up to 2800°C
    Dilatometry DIL is a technique in which a dimension of a substance under negligible load is measured (e.g. expansion measurement or shrinkage measurement) as a function of temperature while the substance is subjected to a controlled temperature program in a specified atmosphere. Linseis produces a wide range of Single-, Dual-, Differential-, Quattro-, Quenching-, Laser- and Optical Dilatometer in a temperature range from -180°C up to 2800°C and a resolution up to 0.3 nm. Thanks to our years of experience (est. 1953), Linseis offers Dilatometers with an unbeaten performance.  
  • Differential Scanning Calorimetry (DSC)

    RT up to 600°C -180 up to 600°C
    The all new Chip DSC-sensor integrates all essential parts of DSC, furnace, sensor and electronics in a miniaturized housing. The chip-arrangement comprises the heater and temperature sensor in a chemically inert ceramic arrangement with metallic heater and temperature sensor. This arrangement allows superior reproducibility and due to the low mass outstanding temperature control and heating rates of up to 300°C/min. The integrated sensor is easily user exchangeable and available for a low cost. The integrated design of the chip-sensor delivers superior raw data, which enables a direct analysis without pre- or post-processing of heat flow data.
  • Ultrapure Water Purification

    delivering ultrapure 18.2 MΩ cm water
    Ultrapure water is elemental to the success of your experiments. But finding the right water system for your research goes deeper than water quality alone. You need a smart choice that supports both your science and your budget — on day 1, and with every cartridge and filter change. One that reflects 130 years of innovations, like feed water monitoring, hands-free dispensing and effortless cartridge change-outs. With a Thermo Scientific lab water system, the only thing you’ll have in your water is confidence. Suitable for even the most demanding and sensitive applications, the family of Thermo Scientific GenPure water purification systems exceeds international standards ASTM D1193 Type 1, ISO 3696 Grade 1 and CLSI-CLRW, delivering ultrapure 18.2 MΩ cm water with consistent quality.
  • SEM EM Series

    Scanning Electron Microscope analysis
    TABLE TOP SEM EM SERIES – TOTAL SEM SOLUTION The SEM can implemented with Elemental analysis functions at the same time. This way you can use your exhisting and preffered brand like oxford, bruker or EDAX to provide the SEM with EDS analysis. In addition, as an integrated device, the equipment can be used at a lower cost than the separately purchased products.
  • Escort MINI

    Self-sufficient data logger that measures temperature
    We have a whide variaty of sensors, loggers/recorders for temperature and humidty. Digital temperature data logger with display Escort MINI is a self-sufficient data logger that measures temperature. To start logging, a brief pressure on start button is enough. A large LCD display provides log information and alarm status. Escort MINI’s enclosure is made of ABS plastic and has an optional internal or external probe. The internal memory logs up to 1868 readings, with a sample rate from 1 up to 255 minutes. iLog is a self-powered temperature data logger. An excelent resolution of 0,1ºC along with a high accuracy of ±0,3ºC gives the iLog the capability to detect and to log the smallest variations of temperature. A large LCD display and external indicators provide log information and alarm status. The internal memory logs up to 32000 readings, with a sample rate from 1 second up to 10 days.
  • IGC SEA Surface energy analyzer

    Up to 12 different probe gas molecules
    The Inverse Gas Chromatography-Surface Energy Analyzer or iGC-SEA continues Surface Measurement Systems’ pioneering history with inverse gas chromatography (IGC). The iGC-SEA is a second generation Inverse Gas Chromatography instrument. It is the only commercial instrument based on IGC principle. The unique SMS injection scheme provides a wide range of injection concentrations with high accuracy and reproducibility.
  • The Protea 2000 emissions monitoring system is approved forthe analysis of exhaust gases from the engines and boilers of ships and offshore rigs. Robust and with proven reliability, up to six gases can be measured including SO2,CO2 The Protea 2000 emissions monitoring system comprises up to 8 exhaust mounted analysers, each with automatic verification facilities. Emissions data from the entire system is securely managed and displayed at a dedicated Classification Society approved panel PC, with outputs to networks, control systems, and reporting facilities.
  • ProMass Transportable

    Draagbare Quadrupole Mass Spectrometer (QMS) analyser
    For use in the field, ProMass can be provided in a rugged mobile case. With a vacuum start-up in less than 40mins, ProMass can be deployed quickly. Using either the simple PAS-Pro software for unattended operation, or the more complex PAS software for investigation work, ProMass Transportable can give real-time, wide range measurements of any gas.
    • Leak testing (sniffer mode)
    • Syngas analysis
    • Environmental testing
    • Dissolved gas analysis (with membrane inlet)