Due to its modular design and various options, the Ankersmid heated sample probe filters cover the widest range of applications. With a choice of different lengths of heated filter body, a filter element of 150mm length, suitable for most applications up to 1g dust/m3 can be integrated. 180mm filters with a larger filter surface are used for applications up to 4g dust/m3; with the blow- back function dust loads of up to 10g/m3 can be handled. The 500mm model filter of the ASP 1500 has a capacity for dust up to 10g/m3. When this type is equipped with blow-back option, it handles up to 20g/m3. For even higher dust loads, a primary filter is positioned on top of the first filter. A significant advantage is that all filters are replaceable without dismounting the probe without using any tools and in the shortest possible time. Cleaning and exchanging of unheated sample tubes or preliminary top-filters can be affected by extracting the filter from the probe. The probe temperature is controlled by a microprocessor based PID-controller (optional with Modbus/RS485 communication). Alarm or fault contacts can be programmed and the temperature can be changed easily. The standard sensor is PT100, whereas a thermo-couple is standard for the high temperature version.
-
The Ankersmid Humidifier controls the humidity of the gas sample stream. The Humidifier is used to wet calibration gases to ensure these gases undergo an identical cycle through the conditioning set-up.
In this set-up, the calibration gases enter the cooler saturated at a stable dew point. Calibration gases with water-soluble components must not be passed through the humidifier.
-
Ons assortiment zuurstofanalysatoren is ontworpen om gas te bewaken dat wordt geproduceerd of gebruikt in industriële processen waar zuurstofspoor van lage deeltjes per miljoen tot pure O2 nauwkeurig moet worden gemeten. Door gebruik te maken van de hoogwaardige galvanische zuurstofsensoren van AII zijn deze geavanceerde instrumenten eenvoudig te gebruiken met een gemeenschappelijke HMI en menustructuur voor het hele bereik. Operators hoeven slechts één instrument te leren voor meerdere gasanalysetoepassingen bij verschillende zuurstofniveaus. Verkrijgbaar als bench-, 19 "rack-, panel- en wandmontage voor flexibele installatie.
-
Deze robuuste draagbare instrumenten zijn geschikt voor sporen zuurstofmetingen van 0,1 ppm tot zuiverheid toepassingen bij 100% zuurstof en delen dezelfde geavanceerde sensortechnologie als de online proces zuurstof analysatoren, waardoor u kunt vertrouwen op hun betrouwbaarheid en nauwkeurigheid. Het concept van Analytical Instruments, waarbij dezelfde HMI en menustructuren worden gebruikt voor draagbare en online analysers, maakt het voor operators uiterst eenvoudig om beide soorten instrumenten op hun locatie te gebruiken zonder dat er extra training nodig is.
-
De GPR-7100 is een draagbare H2S-analyser-versie die bij voorkeur wordt gebruikt voor het ter plaatse controleren van het proces of tijdelijk gebruik tijdens onderhoud of inbedrijfstelling van een permanente gasanalysator. Deze geavanceerde instrumenten van AII zijn goedgekeurd voor gebruik in ontvlambare gasstromen.
-
Heated Inlet Protection Filter model number 1035 is made for filtering the particles from a size of 5μ and bigger out of the samplegas. The Operation time of an Testa-FID without a build in filter (Model 123) can lengthened several times, because this fine filter helps to minimize the change of the sample capillary, the cleaning of the pump and minimize the maintenance. All the spikes you can see without filter are eliminated with our model 1035.
-
The heated prefilter model iFiD FIlter XL is a samplegasfilter for the high temperature applications with a permanent temperature of 300°C. The filter is very stable with the temperature level you preselect, and also in permanent operation. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of + 1%.
-
The heated transferline is made of a stainless steal tube with soldered heater. This construction is unique in relation to other lines and is guarantee for a very good heattransfer. Especially in cases of alternating process temperatures, the sample temperature can stabilized at preselected level. A Low-Cost-Version is available with simple teflon hose.
-
Reliable process control for furnaces, metal industry, semiconductor and gas separation. The analyser continuously measures the concentration of gases such as H2, He, and Ar with high stability. It is also available in a version for hazardous areas (for countries outside the European Union): ZAFE certified Ex NEPSI.
-
19" RackFlame-Ionisation-Detector iFiD Rack for continuous monitoring of 2 channels parallel
The stationary Flame-Ionisation-Detector iFiD Dual is designed for measuring at two points with one unit. This saves money in comparison to a 2 unit solution. The channels are separated from each other and so you can permanently measure high and low concentrations paralell without switching procedure. -
The stationary Flame-Ionisation-Detector (FID) iFiD NMHC measures with its built in NMHC Cutter the methane concentration and parallel in a second channel also the THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability. All components which come in contact with sample are fully heated at 200°.
-
19" Rack Flame-Ionisation-Detector iFiD SHED for continuous monitoring
The stationary Flame-Ionisation-Detector (FID) iFiD SHED was designed as a 19" Rackunit. This analyzer is designed to measure volatile organic compounds in different sized SHED-chambers. The device is available in a bypass circuit version and an extraction version. The special advantage of the extraction version is a sample flow of only 12-15ml per minute. The whole gaspath is heated to 200°C and with its unique Pyrolysis cleaning system you can clean easily and save service costs. -
Outdoor Flame-Ionisation-Detector iFiD Mobile for continuous monitoring
The stationary Flame-Ionisation-Detector (FID) iFiD Wall is made for rough conditions and field installations. This unit measures the Total Hydrocarbon concentration especially in heavy industrial environment or freeair installations with small weatherprotection. The stainless steelhousing with a protection class IP65 gives the analyser a strong shelter all year long. -
Optimization of combustion efficiency and compliance with environmental standards Ideal for combustion control in boilers, incinerators and furnaces. Lowering CO₂, SOx, and NOx emissions while saving energy This oxygen analyser is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion management and control, such as garbage incinerators and smallest to largest sized boilers, as combustion controllers, achieving a significant energy-saving effect.
-
LaserGas™ II Multi Pass combineert extractieve metingen met een compact analyserontwerp. De laserstraal wordt gekoppeld aan een meetcel, waar deze meerdere keren wordt gereflecteerd tussen twee bolvormige spiegels om de gevoeligheid van de analysator te vergroten. De monitor is een kant-en-klaar instrument. Tijdens de installatie zijn geen andere handelingen nodig dan het aansluiten van stroom, het meetgas en optionele spoeling. LaserGas™ MP biedt een betrouwbare en gebruiksvriendelijke oplossing voor een breed scala aan toepassingen.
-
LaserGas™ II Open Path is a compact, high performance gas monitor for ambient long distance monitoring. The LaserGas™ II OP consists of a transceiver and retro-reflector unit. The retro-reflector unit consists of one or several cube corners in a weather proof enclosure, which reflects the light back to the transceiver. The detector collects the returned light for calculation of the gas concentration. An optional auto-alignment unit can also be applied to ensure consistent alignment over time.
-
De LaserGas-II-Compact Monitor is afgeleid van de standaard Single Path instrumenten en werd geoptimaliseerd voor toepassingen met korte padlengtes tussen 10 en 100 centimeter. Doordat het toestel is voorzien van een gefocuste laserstraal is het mogelijk door zeer dunne insteekbuisjes te meten (<10 mm diameter). Hierdoor is er bij de SP Compact, voor toepassingen waarbij spoeling van de lens ter voorkoming van stofafzetting noodzakelijk is, slechts een zeer beperkt spoeldebiet vereist. Met de optionele interne deshydratiemiddelen kunnen deze toestellen ook worden geoptimaliseerd voor in-situ meting van sporen niveaus van bv O2 en H2O. De LaserGasTMII SP Compact Monitor bestaat uit een zender / ontvanger (gemonteerd diametraal tegenover elkaar) om de gemiddelde concentratie gas langs de optische meetveld te bepalen.
-
Neo Monitors is trots 's werelds eerste in-situ optische analysator voor waterstof aan te bieden. De LaserGas™ II Single Path Hydrogen is een speciaal ontworpen versie die is afgestemd op waterstofmetingen. De sensor blijft onaangetast door verontreinigingen, corrosieve stoffen en heeft geen regelmatig onderhoud nodig. De afwezigheid van extractieve conditioneringssystemen verbetert de beschikbaarheid van de metingen verder en elimineert fouten met betrekking tot monsterbehandeling. Zodra de voeding, datalijnen en spoeling zijn aangesloten, is het instrument klaar voor gebruik en worden metingen in realtime uitgevoerd.
-
Single Path monitoren zijn ontworpen voor in-situ meting in schoorstenen, leidingen of reactoren met typische padlengte van 0,5 tot 20 meter. By-pass en extractieve configuraties zijn ook mogelijk. Het compacte ontwerp bestaat uit de zender (met laser module, de optische module en de belangrijkste elektronica) en de ontvanger (met focus lens, fotodetector en ontvanger elektronica). De LaserGas II SP Monitor maakt gebruik van een zender / ontvanger configuratie (diametraal tegenover elkaar gemonteerd) om de gemiddelde gasconcentratie over de optische padlengte te bepalen.
-
LaserGas™ III Open Path-gasdetector is speciaal ontworpen voor continue bewaking in explosiegevaarlijke omgevingen. Gebaseerd op onze derde generatie LaserGas™-technologie, is het hele instrument ingebouwd in compacte vuurvaste behuizingen, waardoor het ideaal is voor zone 1-locaties. De LaserGas™ III OP bestaat uit een zender- en ontvangereenheid die tegenover elkaar is gemonteerd op een afstand tot 100 meter. Het laserlicht wordt van de zender naar de ontvanger gestuurd en eventuele veranderingen in de gasconcentratie langs het optische pad van de zender naar de ontvanger worden in realtime gedetecteerd.
-
LaserGas™ III HF Portable analyzer is compact, lightweight and battery powered instrument which is ideal for HF leakage detection. With on-board pump and connections for Teflon tubing the target gas is continuously transferred into the internal measurement cell. The instrument´s low power design gives long operating time on each battery cycle. The analyzer provides reliable operation with instantaneous response and sufficient dynamic range to measure from sub ppm to several hundred ppm HF concentrations.
-
LaserGas™ III SP is the third generation in-situ analyzer, designed for safety applications with a special focus on SIL-applications and Ex-d. A compact sized instrument which is easy to install. The instrument is a placed in a sealed housing which eliminates the need for instrument purging.The instrument does not require regular maintenance. The monitor is mounted directly onto flanges, which include purge gas connections and a tilting mechanism for easy alignment. Continuous purge flow prevents dust and other contamination from settling on the optical windows. Once power and data lines are connected, measurements are performed in real-time.
-
LaserGas™ iQ² analyzer is the first to measure up to four gases (O2, CO, CH4, H2O) and temperature depending on configuration, which eliminates the need for multiple units for combustion analysis. The cutting-edge design and ground-breaking functionality, ensures that the instrument delivers unmatched reliability and durability. Customers may replace existing analyzers where explosion risks or high maintenance issues are a huge concern.
-
LaserGas™ iQ2 Vulcan is the first in-situ single-flange solution to measure up to four gases (O2, CO, CH4, H2O) as well as the process temperature in a single unit. Based on the well-proven and trusted tunable diode laser absorption spectroscopy (TDLAS) technology, the solution combines cutting-edge design and ground-breaking functionality. It is a complete combustion solution eliminating the need for multiple units. Advanced TDLAS technology enables unmatched reliability and durability. Installation costs of this all-in-one solution are significantly reduced since only one flange is needed. In addition, operational and maintenance costs are kept at a minimum.
-
In tegenstelling tot de vorige generaties LaserGas™-producten, meet de LaserGas™ Q-familie in het mid-infraroodspectrum, wat betere detectielimieten mogelijk maakt. Evenals detectie van gassen die niet mogelijk zijn met de meer gebruikelijke nabij-infraroodspectroscopie. De sensor heeft lage onderhoudskosten en vereist geen regelmatig onderhoud. De afwezigheid van extractieve conditioneringssystemen verbetert de beschikbaarheid van de metingen verder en elimineert fouten met betrekking tot monsterbehandeling. De monitor is direct op flenzen gemonteerd, die zijn voorzien van spoelgasaansluitingen en een kantelmechanisme voor eenvoudige uitlijning. Een continue spoelstroom voorkomt dat stof en andere verontreinigingen zich op de optische vensters nestelen. Zodra stroom- en datalijnen zijn aangesloten, worden metingen in realtime uitgevoerd.
-
In tegenstelling tot de vorige generaties LaserGas™-producten, meet de LaserGas™ Q-familie in het mid-infraroodspectrum, wat betere detectielimieten mogelijk maakt. Evenals detectie van gassen die niet mogelijk zijn met de meer gebruikelijke nabij-infraroodspectroscopie. De sensor heeft lage onderhoudskosten en vereist geen regelmatig onderhoud. De afwezigheid van extractieve conditioneringssystemen verbetert de beschikbaarheid van de metingen verder en elimineert fouten met betrekking tot monsterbehandeling. De monitor is direct op flenzen gemonteerd, die zijn voorzien van spoelgasaansluitingen en een kantelmechanisme voor eenvoudige uitlijning. Een continue spoelstroom voorkomt dat stof en andere verontreinigingen zich op de optische vensters nestelen. Zodra stroom- en datalijnen zijn aangesloten, worden metingen in realtime uitgevoerd. Download datasheet