• atmosFIR CEM

    Continuous Emissions Monitoring FTIR
    atmosFIR CEM is a complete emissions monitoring system incorporating the atmosFIR 19” FTIR analyser. As completely hot and wet emissions measurement, atmosFIR CEM is ideal for complete measurement of multiple gases from applications such as incineration and power. A standard gas suite of NO, NO2, N2O, SO2, NH3, HCl, CH4, O2, CO2 and H2O is provided, but with the powerful FTIR analyser, further gases can be added easily in software. At the heart of system is the high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIR has been developed to incorporate the latest improvements and advantages in technology, The atmosFIR FTIR analyser contains an in-built sampling system and is designed for ppm-level emissions monitoring. The analyser can be used as a portable or bench-top unit as well as part of the installed CEM system.
  • atmosFIR

    Multi-component FTIR gas analyser, measuring sub-ppm to low %Vol online
    atmosFIR is the successor to Protea's previous emissions monitoring FTIR systems, keeping all the features that users found valuable in achieving their measurement results, but offering the benefits of the new atmosFIR platform with increased portability, lower ownership costs and increased measurement performance. atmosFIR can be considered a simple multi-gas analyser for combustion gas measurements; indeed for some users that is all it will be and as such it provides a cost-effective and complete measurement system. However, for the expert user atmosFIR will offer all the benefits of FTIR, with hundreds of gas measurements, multiple analytical ranges, in-depth chemometric result diagnoses and dedicated on-board sampling system. With Protea's in-house chemometrics application support and 15+ year history of emission monitoring projects, atmosFIR offers the user the complete package for their monitoring needs. With long-lifetime VCSEL reference laser diode, unique cell design, and air cooled DTGS detector with 24-bit ADC, atmosFIR is a step-change in value and service lifetime for FTIR emission gas analysis.
  • atmosFIRw

    Wall-mounted multigas analyser for ambient air and process monitoring
    atmosFIR is the latest generation of gas analyser technology from Protea. The atmosFIR system improves upon previous FTIR technology and represents one of the most cost-effective and flexible analytical products on the market today. atmosFIRw has been designed to give a complete measurement system with embedded touchscreen controller. At the heart of atmosFIRw is a high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIRw has been developed to incorporate the latest improvements and advantages in technology, including:
    • Low cost of ownership and maintenance
    • Robust and light, including the latest in fabrication materials
    • atmosFIR combines an FTIR analyser with an in-built sampling system and embedded PC controller for a complete system
  • atmosFIRt

    Draagbare multigas FTIR gasanalyser voor emissiemeting
    atmosFIRt is the latest generation of FTIR gas analyser technology from Protea in a portable or mobile form. The atmosFIR system improves upon previous FTIR technology and represents one of the most cost-effective and flexible analytical products on the market today. At the heart of atmosFIR is a high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIR has been developed to incorporate the latest improvements and advantages in technology.
  • ProtIR 204M

    Transporteerbare CEM gebaseerd op FTIR technologie
    The 204M is a transportable CEM based on FTIR technology. Using the 204M for measurements of waste incineration and combustion plant process is as simple using an FTIR can be. With pre-loaded calibration methods for 28 gas species, automatic nitrogen purging, in-built pressure and temperature alarms, analogue and digital I/O it is a complete site-ready back up CEM. The ProtIR 204M and PAS software have been designed to allow stack emission monitoring to be carried out to the Environment Agency’s Technical Guidance Note M22 Measuring stack gas emissions using FTIR instruments (TGN M22) as simply and quickly as possible. With the built-in Standard Analysis Model for common gases there is no complex set-up of analysis required. The software as built-in calculations for drift and residual analysis, following the methods described in TGN M22. Skilled users of the FTIR can use the chemometric building routines of the PAS software to build analytical methods for specific applications. Set up this way, the 204M can measure thousands of possible gas species over ranges from ppm to %Vol.
  • FID 2010 T

    Draagbare Vlam-Ionisatie-Detector FID 2010T voor continue monitoring van CxHy - Classic Line

    Total Hydrocarbon Analyser

    The Flame-Ionisation-Detector 2010 T measures Total HydroCarbon (THC) in a wide range of applications like catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases.By it`s little weight and it`s compact dimensions, he is especially made for daily changing measuring points or shorttime measurings campains.
  • FID 1230 Module

    Vlam-Ionisatie-Detector 1230 Module voor continue monitoring van CxHy

    19" rack version Flame-Ionisation Detector FID 1230

    The Flame-Ionisation-Detector FID1230 Module measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy. Because of the module system, there is an optimal configuration for every measurement-task under profit aspects possible. All modules can be fit in at any time.
  • FID 1230 IH

    The flame-ionization-detector 1230 IH for continuous high temperature (400°C) monitoring of THC

    High-Temperature Analyzer for Exhaust gas measurement

    The flame-ionization-detector 1230I-H can measure the sum of total hydrocarbon concentrationin applications like cold starts of engines (down to–40°Cambient temperature), inwoodburning systems and also at engine test units (especially oil-and gasburners, airplaneengines etc.) Our high temperature heated lines with a operation temperature of 400°C are made additionally for measurements of highboiling hydrocarbons. For the sample-gas pickup we have built some prefilters who are able to hold back the tar compounds.
  • FID 3001W

    Analytical section heated on 300°C

    Wall mount Flame-Ionisation-Detector 3001W

    The Flame-Ionisation-Detector 3001W measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. Because of its swingable housing, there is an easy installation and optimal accessibility guaranteed. This wallmounted analyser is a compact, robust weatherproofed version. The environmental protectionmode is IP65.
  • FID 2010 NMHC

    Draagbare Methaan/CxHy Analyser

    Methaan/THC Analysator

    De draagbare verwarmde FID 2010 NMHC van TESTA meet met zijn ingebouwde NMHC-cutter de methaanconcentratie (alleen methaan) en na overschakeling op een ander kanaal ook de THC in een breed scala aan toepassingen zoals bewaking van schoorsteengasemissies, bewaking van omgevingslucht, monitoring van thermische reactor- en verbrandingsemissies en ook uitlaatgassen van voertuigen. De monitoring is continu met een hoge nauwkeurigheid, gevoeligheid en stabiliteit. Alle componenten die in contact komen met het monster worden volledig verwarmd op 200°.
  • FID 1230 NMHC

    Methane only / CxHy monitoring system (Change-over switch)
    Methane only / Total Hydrocarbon THC monitoring system (Change-over switch) The 19” Flame-Ionisation-Detector (FID) 1230NMHC measures with its built-in NMHC-Cutter the methane concentration (methane only) and after switching to THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability.
  • FID 2000 MP

    Analytical section heated on 200°C
    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in a wide range of applications like all kind of emission control, catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air (immissions), solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy.
  • FID 2000MP SHED

    Connection for 4 calibration gases

    Mini/Micro-SHED

    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in SHED-chambers of different sizes. For applications beginning of 2,5m3 we recommend to measure in a heated circular system to get a response time near to real changes of concentration in the chamber. For smaller chambers, we have developed a special FID-analyzer with a sample flow of 12ml/min. These two types of analyzers optimizethe air change rateover the extraction rate.
  • ProMass Desktop

    closed ion source and 0-200amu range
    Laboratory QMS Gas Analyser For laboratory applications across many fields of research, the ProMass analyser can be provided in a desktop format. With integrated vacuum system – turbo molecular drag pump and diaphragm roughing pump – ProMass can be operated straight away. A heated capillary of various materials (stainless steel, PEEK, PTFE, borosilicate) is provided included with temperature control of the capillary. Total pressure gauge, analogue and digital inputs, sample pressure and temperature controlled chamber bake-out are all built-in features to give complete sample control.   ProMass uses Protea’s proven RGA quadrupole mass spectrometer that is provided as standard with dual Faraday/SEM detector, closed ion source and 0-200amu range for the analytically focused applications of the ProMass desktop system.
  • Ideally suited to semiconductor production processes, ambient air measurements, leak testing and quality testing for the food industry, the 19” mountable ProMass analyser is a complete process tool. ProMass can be provided with fully integrated vacuum system, or for demanding process applications, an external backing pump is provided – particularly for hazardous area applications. Protea will integrate the ProMass analyser with our sampling control system and industrial analyser controller for a complete measurement system. This can be provided to measure from multiple sample locations is quick succession.
  • ProMass Transportable

    Draagbare Quadrupole Mass Spectrometer (QMS) analyser
    For use in the field, ProMass can be provided in a rugged mobile case. With a vacuum start-up in less than 40mins, ProMass can be deployed quickly. Using either the simple PAS-Pro software for unattended operation, or the more complex PAS software for investigation work, ProMass Transportable can give real-time, wide range measurements of any gas.
    • Leak testing (sniffer mode)
    • Syngas analysis
    • Environmental testing
    • Dissolved gas analysis (with membrane inlet)
    • Gas impurity testing
Ga naar de bovenkant