• nCLD EL

    NO / NOx - 0.5 ppm -500 ppm

    ECO PHYSICS nCLD EL

    Gas Analyzer The nCLD EL is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
  • nCLD 66 Y

    NO / NOx - 50 ppb – 25’000 ppb

    ECO PHYSICS nCLD 66 Y

    Gas Analyzer The nCLD 66 Y is the next generation in single-channel ambient air monitoring instrumentation. Unique in speed and precision, the nCLD 66 Y is modular designed and capable of sequentially measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen oxide based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD EL S

    NO / NOx - 5 ppm –5’000 ppm

    ECO PHYSICS nCLD EL S

    Gas Analyzer The nCLD EL S is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL S is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data. connects to other instruments’ data.
  • iFID Dual

    Continuous monitoring of two parallel channels

    19" RackFlame-Ionisation-Detector iFiD Rack for continuous monitoring of 2 channels parallel

    The stationary Flame-Ionisation-Detector iFiD Dual is designed for measuring at two points with one unit. This saves money in comparison to a 2 unit solution. The channels are separated from each other and so you can permanently measure high and low concentrations paralell without switching procedure.
  • iFID Shed

    19" Rack Flame-Ionisation-Detector iFiD SHED for continuous monitoring

    19" Rack Flame-Ionisation-Detector iFiD SHED for continuous monitoring

    The stationary Flame-Ionisation-Detector (FID) iFiD SHED was designed as a 19" Rackunit. This analyzer is designed to measure volatile organic compounds in different sized SHED-chambers. The device is available in a bypass circuit version and an extraction version. The special advantage of the extraction version is a sample flow of only 12-15ml per minute. The whole gaspath is heated to 200°C and with its unique Pyrolysis cleaning system you can clean easily and save service costs.
  • iFID Wall

    Outdoor Vlamionisatiedetector iFiD voor continue CxHy bewaking

    Outdoor Flame-Ionisation-Detector iFiD Mobile for continuous monitoring

    The stationary Flame-Ionisation-Detector (FID) iFiD Wall is made for rough conditions and field installations. This unit measures the Total Hydrocarbon concentration especially in heavy industrial environment or freeair installations with small weatherprotection. The stainless steelhousing with a protection class IP65 gives the analyser a strong shelter all year long.
  • iFiD Rack

    19" rack vlamionisatiedetector voor continue CxHy bewaking

    19" Rack vlamionisatiedetector voor continue CxHy bewaking

    De stationaire vlamionisatiedetector (FID) iFiD Rack is ontworpen voor stack monitoring, proces controle alsook voor VOC meting. Het volledige gaspad is verwarmd op 300°C, vandaar we kunnen spreken van een hoge temperatuur FID.
  • iFID Mobile

    Draagbare Vlamionisatiedetector voor continue CxHybewaking

    Draagbare Vlamionisatiedetector

    De vlamionisatiedetector (FID) meet de totale koolwaterstofconcentratie in industriële en laboratoriumomgevingen. Door zijn lichtgewicht en compacte afmetingen is hij speciaal gemaakt voor dagelijks wisselende meetpunten of kortstondige metingen.
  • The ALS liquid-stop protects analyzers against an inrush of liquids from the gas conditioning unit into the analyzer.

    This avoids major damages of the analyser.

    The best position of the liquid is behind the gas conditioning unit, and before the flow meter going to the analyser.

  • Draagbare Gasmonstername Probe APP

    met verwarmd filter (180°C)

    Due to various acid dew points at various applications the probe is heated up to 180°C.

    A filter element of 150mm is integrated, suitable for most applications up to 1g dust/m3. A significant advantage is that this filter is replaceable without dismounting the probe. With the filter element of 150mm length this probe is suitable for most applications up to 1g dust/m3; with the blow-back function dust loads of up to 10g/m3 can be handled.

    Calibration gas can be injected directly into the probe through the calibration gas connection according to EN14181 (regulation for calibration of emission monitoring systems) that enables calibration gas feeding via the filter element of the gas sample probe. The use of the optional high-flow check valve type APP 200 is recommended.

    The portable gas sample probe series APP is a perfect completion to the Ankersmid portable gas conditioning system series APS 303/313. Both devices can easily be connected together by the Ankersmid heated sample line type AHL205/025 with the incorporated innovative Quick-Lock System which guarantees a fast and reliable connection.

    Using this heated line the probe's electrical power is then fed to the probe via the feed line integrated within the sample line. To avoid cooling-down and condensation of sample gas in the extraction area, the heated sample probe tube type AST 301 is available.

  • Draagbaar systeem APS

    Draagbaar gasconditioneringssysteem

    The portable system is suitable for variable, discontinuous and continuous operation. The components built into the system can be used for standard applications. For special requirements please ask us for other solutions.

    The heated sample line is to be mounted at the gas measuring inlet terminal inside the portable case. A ball-valve can be fitted to the inlet terminal of the portable system in order to calibrate analyser(s) with check gas.

    The amount of flow is determined by a sample gas diaphragm pump. The sample gas pump AMP 11P is activated automatically by means of an excess temperature contact on the cooler.

    Optional flow meters with integrated needle valve are available. The flow meters are built-in as the electronic controller and are visible from outside when the carrying case is closed. This unique microprocessor controlled Peltier cooler is a powerful designed dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1°C and 15°C. The gas cooler is equipped with an innovative heat exchanger system.

  • LaserGas II OP

    Open pad gasmonitor over lange afstand
    LaserGas™ II Open Path is a compact, high performance gas monitor for ambient long distance monitoring. The LaserGas™ II OP consists of a transceiver and retro-reflector unit. The retro-reflector unit consists of one or several cube corners in a weather proof enclosure, which reflects the light back to the transceiver. The detector collects the returned light for calculation of the gas concentration. An optional auto-alignment unit can also be applied to ensure consistent alignment over time.
  • LaserGas iQ² Vulcan

    Single-flange O2, CO, CH4, H2O analyser
    LaserGas™ iQ2 Vulcan is the first in-situ single-flange solution to measure up to four gases (O2, CO, CH4, H2O) as well as the process temperature in a single unit. Based on the well-proven and trusted tunable diode laser absorption spectroscopy (TDLAS) technology, the solution combines cutting-edge design and ground-breaking functionality. It is a complete combustion solution eliminating the need for multiple units. Advanced TDLAS technology enables unmatched reliability and durability. Installation costs of this all-in-one solution are significantly reduced since only one flange is needed. In addition, operational and maintenance costs are kept at a minimum.
  • LaserGas III Portable

    Draagbare HF analyser
    LaserGas™ III HF Portable analyzer is compact, lightweight and battery powered instrument which is ideal for HF leakage detection. With on-board pump and connections for Teflon tubing the target gas is continuously transferred into the internal measurement cell. The instrument´s low power design gives long operating time on each battery cycle. The analyzer provides reliable operation with instantaneous response and sufficient dynamic range to measure from sub ppm to several hundred ppm HF concentrations.
  • LaserGas iQ²

    Meet tot 4 gassen O2, CO, CH4, H2O
    LaserGas™ iQ² analyzer is the first to measure up to four gases (O2, CO, CH4, H2O) and temperature depending on configuration, which eliminates the need for multiple units for combustion analysis. The cutting-edge design and ground-breaking functionality, ensures that the instrument delivers unmatched reliability and durability. Customers may replace existing analyzers where explosion risks or high maintenance issues are a huge concern.
  • LaserDust

    Compacte optische in-situ stofmonitors
    LaserDust™ Medium Path (MP), Long Path (LP) en Extra Long Path (XLP) monitoren zijn compacte, optische stofmonitors voor echte continue in-situ meting van stofconcentratie of opaciteit. De monitoren zijn ontworpen voor metingen over pijpen, schoorstenen en kanalen met typische padlengtes van 0,5 – 10 m. LaserDust™-monitoren gebruiken een zender/ontvangerconfiguratie om de stofconcentratie langs de optische zichtlijn te meten. Onze echte contactloze benadering is superieur aan stofmeters van het punttype. Met innovatieve lasertechnologie combineert de LaserDust™ twee meetprincipes in één instrument.
    • Bij lage stofniveaus werkt het met voorwaartse strooilichttechnologie: Het invallende laserlicht wordt verstrooid door stofdeeltjes en verzameld op een solid-state sensor voor stofkwantificering. Deze zeer gevoelige modus maakt detectiegrenzen van < 0,5 mg/Nm3 mogelijk en wordt niet beïnvloed door stofafzetting op de vensters.
    • Bij hoge stofniveaus meet de LaserDust™ de doorlaatbaarheid of opaciteit: Lichtabsorptie door stofdeeltjes wordt opgevangen door een 2e sensor.
Ga naar de bovenkant