• FID 2000MP SHED

    Connection for 4 calibration gases

    Mini/Micro-SHED

    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in SHED-chambers of different sizes. For applications beginning of 2,5m3 we recommend to measure in a heated circular system to get a response time near to real changes of concentration in the chamber. For smaller chambers, we have developed a special FID-analyzer with a sample flow of 12ml/min. These two types of analyzers optimizethe air change rateover the extraction rate.
  • FID 2000 MP

    Analytical section heated on 200°C
    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in a wide range of applications like all kind of emission control, catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air (immissions), solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy.
  • FID 1230 NMHC

    Methane only / CxHy monitoring system (Change-over switch)
    Methane only / Total Hydrocarbon THC monitoring system (Change-over switch) The 19” Flame-Ionisation-Detector (FID) 1230NMHC measures with its built-in NMHC-Cutter the methane concentration (methane only) and after switching to THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability.
  • FID 1230 Module

    Vlam-Ionisatie-Detector 1230 Module voor continue monitoring van CxHy

    19" rack version Flame-Ionisation Detector FID 1230

    The Flame-Ionisation-Detector FID1230 Module measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy. Because of the module system, there is an optimal configuration for every measurement-task under profit aspects possible. All modules can be fit in at any time.
  • FID 1230 IH

    The flame-ionization-detector 1230 IH for continuous high temperature (400°C) monitoring of THC

    High-Temperature Analyzer for Exhaust gas measurement

    The flame-ionization-detector 1230I-H can measure the sum of total hydrocarbon concentrationin applications like cold starts of engines (down to–40°Cambient temperature), inwoodburning systems and also at engine test units (especially oil-and gasburners, airplaneengines etc.) Our high temperature heated lines with a operation temperature of 400°C are made additionally for measurements of highboiling hydrocarbons. For the sample-gas pickup we have built some prefilters who are able to hold back the tar compounds.
  • FDS 18

    Real-time measurement of PM2,5 
    • real-time measurement of PM2,5
    • Monitoring of fine dust concentrations in ambient air and/or at workplaces
    • optical sensor including fitting with clip system, therefore easily exchangeable
    • active and automatic zero point setting
    • active air suction
    • Integrated pre-separator for particles > 2,5 µm
    • noiseless operation
    • network-compatible
  • FDS 17 m

    Simultane real-time meting van PM10 & PM2.5
    • simultaneous real-time measurement of PM10 & PM2.5
    • based on optical sensor, active suction & patented electrostatic precipitator for zero point setting
    • flexible use - indoors & outdoors -
    • portable case with offline power supply by power bank
    • including data logger for storage of measuring values
  • FDS 17

    simultaneous real-time measurement of PM10/ TSP and PM2.5
    • optical sensor for continuous, simultaneous measurement and control of fine dust contents PM10/TSP and PM2,5
    • patented zero point control by electrostatic precipitator
    • smart, robust, network-capable
    • simple unit design
    • installation without any special tools
  • FDS 15

    real-time measurement (PM10 or PM2.5)

    Optical sensor for continuous measurement and monitoring of fine dust contents indoor and outdoor.

    • optical sensor for continuous measurement and monitoring of fine dust concentrations (PM10, PM2.5)
    • smart, robust, network-capable
    • simple unit design
    • installation without any special tools
  • Fuji Electric Extractive Gas Analyzers for process control and continuous measurement of stack emissions. Their QAL1 certification guarantees high performance and regulatory and normative compliance. Reliable and precise, their design quality guarantees 24-hour operation in difficult environments such as smoke from industrial chimneys. Robustness reduces maintenance costs and increases the availability of boilers and equipment. Extractive measurement consists of taking a gas flow from the chimney or the gas pipe via a sampling probe and conveying it to the gas analyzer. The gas is sampled, treated in order to ensure optimal conditions for gas measurement.
  • Draagbare Gasmonstername Probe APP

    met verwarmd filter (180°C)

    Due to various acid dew points at various applications the probe is heated up to 180°C.

    A filter element of 150mm is integrated, suitable for most applications up to 1g dust/m3. A significant advantage is that this filter is replaceable without dismounting the probe. With the filter element of 150mm length this probe is suitable for most applications up to 1g dust/m3; with the blow-back function dust loads of up to 10g/m3 can be handled.

    Calibration gas can be injected directly into the probe through the calibration gas connection according to EN14181 (regulation for calibration of emission monitoring systems) that enables calibration gas feeding via the filter element of the gas sample probe. The use of the optional high-flow check valve type APP 200 is recommended.

    The portable gas sample probe series APP is a perfect completion to the Ankersmid portable gas conditioning system series APS 303/313. Both devices can easily be connected together by the Ankersmid heated sample line type AHL205/025 with the incorporated innovative Quick-Lock System which guarantees a fast and reliable connection.

    Using this heated line the probe's electrical power is then fed to the probe via the feed line integrated within the sample line. To avoid cooling-down and condensation of sample gas in the extraction area, the heated sample probe tube type AST 301 is available.

  • Draagbaar systeem APS

    Draagbaar gasconditioneringssysteem

    The portable system is suitable for variable, discontinuous and continuous operation. The components built into the system can be used for standard applications. For special requirements please ask us for other solutions.

    The heated sample line is to be mounted at the gas measuring inlet terminal inside the portable case. A ball-valve can be fitted to the inlet terminal of the portable system in order to calibrate analyser(s) with check gas.

    The amount of flow is determined by a sample gas diaphragm pump. The sample gas pump AMP 11P is activated automatically by means of an excess temperature contact on the cooler.

    Optional flow meters with integrated needle valve are available. The flow meters are built-in as the electronic controller and are visible from outside when the carrying case is closed. This unique microprocessor controlled Peltier cooler is a powerful designed dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1°C and 15°C. The gas cooler is equipped with an innovative heat exchanger system.

  • CraNOx II

    NO, NO₂, NOₓ, O₃ - 1 ppb – 1’000 ppb
    SupremeLine Trace Gas Analyzer With CraNOx II, ECO PHYSICS is launching the second generation of its high-end measurement solution in the ppb and ppt range. The new system is smaller and more sophisticated, as it now has the power to calculate the photostatic equilibrium by means of the integrated ozone analyzer. The CraNOx II system is capable of simultaneously measuring NO, NOX, NO2 and O3. Furthermore, it can be expanded to assess NOY and NH3 concentrations.
  • Backwash M2

    Filter iFiD
    The heated prefilter model iFiD Backwash M2 is a samplegasfilter which can be flushbacked. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Backwash M1

    Filter Model iFiD
    The heated prefilter model iFiD Filter Backwash M1is a samplegasfilter which can flushbacked with an electronic solenoid valve. This valve can controll the pressure air (flushbackair) and the sample gas. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • The heated sampling system is a combination of a heated sample line and a heated sample filter. The sample line is 500mm long; the filter element can be replaced very quick with the bayonet lock. Beside the very precisious and constant regulation of the line and filter temperature, there is a separate controll point fort he temperature at the filterinlet, where you have an information of the exhaust gas temperature. Also the calibration gas (prewarmed) can directly connected with the unit. The thermocouple is available as PT 100 or NiCrNi.
Ga naar de bovenkant