• GPR-7100

    Kosteneffectieve monitoring van waterstofsulfide niveaus
    De GPR-7100 is een draagbare H2S-analyser-versie die bij voorkeur wordt gebruikt voor het ter plaatse controleren van het proces of tijdelijk gebruik tijdens onderhoud of inbedrijfstelling van een permanente gasanalysator. Deze geavanceerde instrumenten van AII zijn goedgekeurd voor gebruik in ontvlambare gasstromen.
  • 2900M Online Monitor & Control System

    YSI 2900 Biochemistry Analyzer with YSI 2960 Online Monitor and Control System.
    The YSI 2900M Online Monitoring & Control System featuring the YSI 2960 Online Sampler is a key and reliable partner for the monitoring and optimization of your bioprocess. The YSI 2960 Online Sampler automatically draws fluids from your bioreactor and delivers samples directly to the YSI 2900 Biochemistry Analyzer for testing. Sampling is done aseptically as lines are flushed and antiseptic is kept in them after each draw. The system supports connection with RS232, Ethernet, and OPC. The YSI 2900M Online Monitoring & Control System provides a simple and reliable solution for running your bioprocess automatically with little risk of contamination.
  • YSI 2950D

    Biochemistry Analyzer with up to 3 biosensor modules
    YSI has earned a reputation as the Gold Standard in bio-analytical instruments with highly accurate sensors and rapid results. The key to generating analyte-specific results in 60 seconds or less is YSI's innovative biosensor technology. Using the inherent specificity of enzymes for a single target analyte, YSI's proprietary immobilized enzyme electrodes allow a rapid, accurate and largely interference free measurement to be made in about a minute. The unique fluidics and chamber design resist clogging - even at high cell densities. If you don't need online monitoring and only need 2 chemisitries, you may be interested in the YSI 2900D. We also offer the 2900M with online monitoring with 2 parameters!
  • YSI 2500

    Biochemistry Analyzer
    YSI has earned a reputation as the Gold Standard in bio-analytical instruments with highly accurate sensors and rapid results.
    • Analyte-specific results in 60 seconds or less
    • Proprietary immobilized enzyme electrodes
    • Unique fluidics resist clogging
    • Trusted measurement technology
    • Automated sample handling
    The YSI 2500 features an intuitive graphical user interface, a USB port for data retrieval, and the ability to measure samples from a variety of sample holders including 96 well plates and microcentrifuge tubes.
  • YSI 2940-2980

    Multi-Channel Online Monitor
    For multiple and parallel bioreactor systems, our 4-channel and 8-channel sampling systems provide many simple and reliable online monitoring and control solutions for your bioreactor processes. Closed-loop monitoring and control capabilities are easily achieved for any scale of operation or type of bioreactor, including single-use systems.  
  • Aurora 1030D

    TOC Analyzer
    Experience two types of TOC analysis in one powerful instrument! Use the Aurora 1030D to analyze TOC through the proven heated persulfate wet oxidation technique or the high temperature combustion method. Both modes have distinct chamber features to ensure accurate and reliable results.  
  • 1080

    Total Organic Carbon (TOC) Analyzer
    Total organic carbon (TOC) measurement is a well-established technique that provides valuable information about water quality for process control and regulatory compliance. Though high-temperature combustion TOC has been shown to be very effective for the analysis of samples that are of high molecular weight or contain substantial amounts of salt or difficult-to oxidize organics (e.g, humic acid), these types of samples are problematic for combustion TOC analyzers.    
  • Aurora 1030W

    TOC Analyzer
    The Aurora 1030 line of TOC analyzers from OI Analytical includes instrument configurations for laboratory and process monitoring, employing 100 °C persulfate wet oxidation or thermal combustion techniques. The Aurora 1030 line incorporates several noteworthy innovations and can be equipped with parallel reactors allowing concurrent sample processing for increased analytical throughput. The unique 1030D Dual Mode TOC analyzer allows sample processing by wet oxidation or thermal combustion using the same instrument.
  • MMS

    Measuring ranges from 0.01 μg/m³ to 2000 μg/m³ Hg
    The MMS system basically comprises a multiplexer-valve unit and the highly accurate and selective mercury detector VM-3000 Vapor Monitor. A bypass pump maintains a steady flow of sample through the sample filters, sample lines and multiplexer valves. Flow meters with optical alarm sensors guarantee that flow rates are stable. All components are installed inside a protective cabinet.
  • The UT-3000 Ng mobile is specifically designed to measure ultratrace amounts of mercury in natural gas at differing sites. The system, for example, thus allows to monitor the efficiency of different Mercury Removal Units (MRUs) in natural gas processing plants.
  • Portable Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
  • Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
  • The analyzers can measure the concentration of multiple gases simultaneously. It is based on the single source dual-beam non-dispersion infrared (NDIR) method for CO, CO2 , CH4 , CnHm, H2S , SO2 and a micro-TCD (Thermal Conductivity Detector) gas sensor for H2 and O2 by fuel cell method. The analyzers have a digital pulsable infrared source and dual-beam systems
  • Portable Multicomponent IR Analyzer

    CO, CO2, CH4, CnHm,O2, H2 + BTU index (gas calorific value)
    The analyzers can measure the concentration of multiple gases simultaneously. It is based on the single source dual-beam non-dispersion infrared (NDIR) method for CO, CO2 , CH4 , CnHm, H2S , SO2 and a micro-TCD (Thermal Conductivity Detector) gas sensor for H2 and O2 by fuel cell method. The analyzers have a digital pulsable infrared source and dual-beam systems
  • LaserInspect CIMO4

    All-in-one controle paneel voor de LaserGas™ familie
    NEO Monitors’ LaserInspect™ CIMO4 gives the operator the opportunity to remotely operate up to 4 LaserGas™ analyzers from the same display*. The operator have full status overview in an instance of all instruments and is able to perform maintenance tasks directly from the panel. This HMI is designed for the NEO Monitors LaserGas™ family and can easily be integrated into a cabinet. * Separate Ethernet switch is required to operate multiple analyzers
  • Small, fine, excellent: The Liebherr P78 sensor in conjunction with the Liebherr FMS moisture measuring installation has become indispensable for many industrial processes. The moisture measuring installation was invented in 1985 at the Bad Schussenried factory. Measurement by the Liebherr sensor system is based on the physical principle of capacitance determination in the high-frequency stray field. In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility. Once the sensor has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.