• Fuji Electric Extractive Gas Analyzers for process control and continuous measurement of stack emissions. Their QAL1 certification guarantees high performance and regulatory and normative compliance. Reliable and precise, their design quality guarantees 24-hour operation in difficult environments such as smoke from industrial chimneys. Robustness reduces maintenance costs and increases the availability of boilers and equipment. Extractive measurement consists of taking a gas flow from the chimney or the gas pipe via a sampling probe and conveying it to the gas analyzer. The gas is sampled, treated in order to ensure optimal conditions for gas measurement.
  • FDS 15

    real-time measurement (PM10 or PM2.5)

    Optical sensor for continuous measurement and monitoring of fine dust contents indoor and outdoor.

    • optical sensor for continuous measurement and monitoring of fine dust concentrations (PM10, PM2.5)
    • smart, robust, network-capable
    • simple unit design
    • installation without any special tools
  • FDS 17

    simultaneous real-time measurement of PM10/ TSP and PM2.5
    • optical sensor for continuous, simultaneous measurement and control of fine dust contents PM10/TSP and PM2,5
    • patented zero point control by electrostatic precipitator
    • smart, robust, network-capable
    • simple unit design
    • installation without any special tools
  • FDS 17 m

    Simultane real-time meting van PM10 & PM2.5
    • simultaneous real-time measurement of PM10 & PM2.5
    • based on optical sensor, active suction & patented electrostatic precipitator for zero point setting
    • flexible use - indoors & outdoors -
    • portable case with offline power supply by power bank
    • including data logger for storage of measuring values
  • FDS 18

    Real-time measurement of PM2,5 
    • real-time measurement of PM2,5
    • Monitoring of fine dust concentrations in ambient air and/or at workplaces
    • optical sensor including fitting with clip system, therefore easily exchangeable
    • active and automatic zero point setting
    • active air suction
    • Integrated pre-separator for particles > 2,5 µm
    • noiseless operation
    • network-compatible
  • FID 1230 IH

    The flame-ionization-detector 1230 IH for continuous high temperature (400°C) monitoring of THC

    High-Temperature Analyzer for Exhaust gas measurement

    The flame-ionization-detector 1230I-H can measure the sum of total hydrocarbon concentrationin applications like cold starts of engines (down to–40°Cambient temperature), inwoodburning systems and also at engine test units (especially oil-and gasburners, airplaneengines etc.) Our high temperature heated lines with a operation temperature of 400°C are made additionally for measurements of highboiling hydrocarbons. For the sample-gas pickup we have built some prefilters who are able to hold back the tar compounds.
  • FID 1230 Module

    Vlam-Ionisatie-Detector 1230 Module voor continue monitoring van CxHy

    19" rack version Flame-Ionisation Detector FID 1230

    The Flame-Ionisation-Detector FID1230 Module measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy. Because of the module system, there is an optimal configuration for every measurement-task under profit aspects possible. All modules can be fit in at any time.
  • FID 1230 NMHC

    Methane only / CxHy monitoring system (Change-over switch)
    Methane only / Total Hydrocarbon THC monitoring system (Change-over switch) The 19” Flame-Ionisation-Detector (FID) 1230NMHC measures with its built-in NMHC-Cutter the methane concentration (methane only) and after switching to THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability.
  • FID 2000 MP

    Analytical section heated on 200°C
    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in a wide range of applications like all kind of emission control, catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air (immissions), solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy.
  • FID 2000MP SHED

    Connection for 4 calibration gases

    Mini/Micro-SHED

    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in SHED-chambers of different sizes. For applications beginning of 2,5m3 we recommend to measure in a heated circular system to get a response time near to real changes of concentration in the chamber. For smaller chambers, we have developed a special FID-analyzer with a sample flow of 12ml/min. These two types of analyzers optimizethe air change rateover the extraction rate.
  • FID 2010 NMHC

    Draagbare Methaan/CxHy Analyser

    Methaan/THC Analysator

    De draagbare verwarmde FID 2010 NMHC van TESTA meet met zijn ingebouwde NMHC-cutter de methaanconcentratie (alleen methaan) en na overschakeling op een ander kanaal ook de THC in een breed scala aan toepassingen zoals bewaking van schoorsteengasemissies, bewaking van omgevingslucht, monitoring van thermische reactor- en verbrandingsemissies en ook uitlaatgassen van voertuigen. De monitoring is continu met een hoge nauwkeurigheid, gevoeligheid en stabiliteit. Alle componenten die in contact komen met het monster worden volledig verwarmd op 200°.
  • FID 2010 T

    Draagbare Vlam-Ionisatie-Detector FID 2010T voor continue monitoring van CxHy - Classic Line

    Total Hydrocarbon Analyser

    The Flame-Ionisation-Detector 2010 T measures Total HydroCarbon (THC) in a wide range of applications like catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases.By it`s little weight and it`s compact dimensions, he is especially made for daily changing measuring points or shorttime measurings campains.
  • FID 3001W

    Analytical section heated on 300°C

    Wall mount Flame-Ionisation-Detector 3001W

    The Flame-Ionisation-Detector 3001W measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. Because of its swingable housing, there is an easy installation and optimal accessibility guaranteed. This wallmounted analyser is a compact, robust weatherproofed version. The environmental protectionmode is IP65.
  • The heated prefilter model iFiD Filter is a gasfilter for the high temperature applications who need a permanent temperature up to 300°C. The filter is very stable with the temperature level you can preselected. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of +-1%.
  • The filterinlet model iFiD Filter is a flashbackable filterunit for all heated Testa Samplegasfilters. The filter is usable for exhaust gas from engines as well as for emmission measuring tasks.
  • FL007

    Olie in water analyser
    The Kemtrak FL007 is a fiber optic probe based oil in water monitor. A state-of-the-art combined fluorescence and turbidity measurement assures reliable continuous monitoring of oil and hydrocarbon contamination in water. Mineral oils rich in aromatic content will fluoresce when illuminated with ultraviolet light. The intensity of this fluorescence is dependent upon the polyaromatic hydrocarbon (PAH) content of the oil. Typical oils that fluoresce include fuel oil, crude oil, hydraulic oil and transformer oil.

Titel