• LaserGas III OP

    Voor continue meting van HF of NH3 in Atex omgeving
    LaserGas™ III Open Path-gasdetector is speciaal ontworpen voor continue bewaking in explosiegevaarlijke omgevingen. Gebaseerd op onze derde generatie LaserGas™-technologie, is het hele instrument ingebouwd in compacte vuurvaste behuizingen, waardoor het ideaal is voor zone 1-locaties. De LaserGas™ III OP bestaat uit een zender- en ontvangereenheid die tegenover elkaar is gemonteerd op een afstand tot 100 meter. Het laserlicht wordt van de zender naar de ontvanger gestuurd en eventuele veranderingen in de gasconcentratie langs het optische pad van de zender naar de ontvanger worden in realtime gedetecteerd.
  • LaserGas III Portable

    Draagbare HF analyser
    LaserGas™ III HF Portable analyzer is compact, lightweight and battery powered instrument which is ideal for HF leakage detection. With on-board pump and connections for Teflon tubing the target gas is continuously transferred into the internal measurement cell. The instrument´s low power design gives long operating time on each battery cycle. The analyzer provides reliable operation with instantaneous response and sufficient dynamic range to measure from sub ppm to several hundred ppm HF concentrations.
  • LaserGas III SP

    Cross stack meting voor Atex Zone I, optie SIL2
    LaserGas™ III SP is the third generation in-situ analyzer, designed for safety applications with a special focus on SIL-applications and Ex-d. A compact sized instrument which is easy to install. The instrument is a placed in a sealed housing which eliminates the need for instrument purging.The instrument does not require regular maintenance. The monitor is mounted directly onto flanges, which include purge gas connections and a tilting mechanism for easy alignment. Continuous purge flow prevents dust and other contamination from settling on the optical windows. Once power and data lines are connected, measurements are performed in real-time.
  • LaserGas iQ²

    Meet tot 4 gassen O2, CO, CH4, H2O
    LaserGas™ iQ² analyzer is the first to measure up to four gases (O2, CO, CH4, H2O) and temperature depending on configuration, which eliminates the need for multiple units for combustion analysis. The cutting-edge design and ground-breaking functionality, ensures that the instrument delivers unmatched reliability and durability. Customers may replace existing analyzers where explosion risks or high maintenance issues are a huge concern.
  • LaserGas iQ² Vulcan

    Single-flange O2, CO, CH4, H2O analyser
    LaserGas™ iQ2 Vulcan is the first in-situ single-flange solution to measure up to four gases (O2, CO, CH4, H2O) as well as the process temperature in a single unit. Based on the well-proven and trusted tunable diode laser absorption spectroscopy (TDLAS) technology, the solution combines cutting-edge design and ground-breaking functionality. It is a complete combustion solution eliminating the need for multiple units. Advanced TDLAS technology enables unmatched reliability and durability. Installation costs of this all-in-one solution are significantly reduced since only one flange is needed. In addition, operational and maintenance costs are kept at a minimum.
  • LaserGas Q CF4

    Meet in het mid-infrarood spectrum met lage detectielimiet
    In tegenstelling tot de vorige generaties LaserGas™-producten, meet de LaserGas™ Q-familie in het mid-infraroodspectrum, wat betere detectielimieten mogelijk maakt. Evenals detectie van gassen die niet mogelijk zijn met de meer gebruikelijke nabij-infraroodspectroscopie. De sensor heeft lage onderhoudskosten en vereist geen regelmatig onderhoud. De afwezigheid van extractieve conditioneringssystemen verbetert de beschikbaarheid van de metingen verder en elimineert fouten met betrekking tot monsterbehandeling. De monitor is direct op flenzen gemonteerd, die zijn voorzien van spoelgasaansluitingen en een kantelmechanisme voor eenvoudige uitlijning. Een continue spoelstroom voorkomt dat stof en andere verontreinigingen zich op de optische vensters nestelen. Zodra stroom- en datalijnen zijn aangesloten, worden metingen in realtime uitgevoerd.
  • LaserGas Q ICL

    In-situ Interband Cascade Laser voor SO2, NO, NO2 of HBr
    In tegenstelling tot de vorige generaties LaserGas™-producten, meet de LaserGas™ Q-familie in het mid-infraroodspectrum, wat betere detectielimieten mogelijk maakt. Evenals detectie van gassen die niet mogelijk zijn met de meer gebruikelijke nabij-infraroodspectroscopie. De sensor heeft lage onderhoudskosten en vereist geen regelmatig onderhoud. De afwezigheid van extractieve conditioneringssystemen verbetert de beschikbaarheid van de metingen verder en elimineert fouten met betrekking tot monsterbehandeling. De monitor is direct op flenzen gemonteerd, die zijn voorzien van spoelgasaansluitingen en een kantelmechanisme voor eenvoudige uitlijning. Een continue spoelstroom voorkomt dat stof en andere verontreinigingen zich op de optische vensters nestelen. Zodra stroom- en datalijnen zijn aangesloten, worden metingen in realtime uitgevoerd. Download datasheet
  • LaserGas™ III Ultra

    Voor toepassingen met zeer lange padlengtes en hoge gasconcentraties

    LaserGas™ III Ultra

    It uses the innovative baseline-insensitive TDLAS technique specifically designed for combustion analysis. The Ultra simultaneously meets the requirements of combustion control and safety. That is, high measurement accuracy and high dynamic range with simultaneous real-time measurement capability. Applications with very long path lengths and high gas concentrations are no problem for the Ultra. Thanks to the baseline insensitivity and the use of the proprietary IROSS signal processing, high measurement accuracy is achieved even with complex gas mixtures. LaserGas™ III Ultra CO in combination with LaserGas™ III O2 are a perfect combination for proper combustion control and safety.
  • LaserInspect CIMO4

    All-in-one controle paneel voor de LaserGas™ familie
    NEO Monitors’ LaserInspect™ CIMO4 gives the operator the opportunity to remotely operate up to 4 LaserGas™ analyzers from the same display*. The operator have full status overview in an instance of all instruments and is able to perform maintenance tasks directly from the panel. This HMI is designed for the NEO Monitors LaserGas™ family and can easily be integrated into a cabinet. * Separate Ethernet switch is required to operate multiple analyzers
  • Liebherr sensors

    In use in explosion-protected areas
    The self-sufficient measuring device for precise water content/moisture determination in the running process guarantees the highest quality and safety in EX-protected production environments, the further processing and refinement of very many emulsions and bulk materials. The PC software enables fast and accurate calibration of the measured sections.

    Liebherr offers sensors for the following device protection categories:

    Gas EX-protection: II 1/2 G Ex db/ia IIC T4 Ga/Gb* Dust EX-protection: II 1/2 D Ex tb/ia IIIC T135°C Da/Db* *Subject to type approval
    The sensors are installed directly in pipes or in tanks. The sensors are used, for example, in oils, crude oils, paints, lacquers, ethanol, solvents as well as in bulk materials under explosive conditions.
  • The ALS liquid-stop protects analyzers against an inrush of liquids from the gas conditioning unit into the analyzer.

    This avoids major damages of the analyser.

    The best position of the liquid is behind the gas conditioning unit, and before the flow meter going to the analyser.

  • Litronic FMS II

    Evaluation and transfer module
    A self-sufficient system with almost unlimited possibilities. The Litronic FMS II type moisture measuring installation has been used for decades in a wide range of industries to measure the moisture content of various materials in real time.At the beginning of each measurement section, the calibration per product must be carried out by means of reference procedures. The Litronic-FMS II software enables convenient and fast parameterisation. The evaluation unit receives the raw values measured by the Liebherr sensors and immediately converts them into percentage humidity. Thanks to the various interfaces, transfer to a higher-level control is possible. Measurement by the Liebherr sensor system is based on the physical principle of capacitance determination in the high-frequency stray field. In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility. Once the system has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.
  • Litronic FMS IV

    Evaluation and transfer module PROFINET
    A self-sufficient moisture measuring installation with high connectivity and many interesting possibilities. With ProfiNet technology on board, extensive signal processing and WEB-based access, we are ready for Industry 4.0. Without Ethernet support, these tasks cannot be accomplished. At the beginning of each measured section, the calibration per product must be carried out by means of reference procedures. The Litronic-FMS IV software enables convenient and rapid parametrisation. The evaluation unit receives the raw values measured by the Liebherr sensors and immediately converts them into the measured value, such as percentage humidity. Up to 16 sensors can be managed via the WEB with one device. A curve manager and material and sample management helps the user to create the product-specific calibration. Once the system has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age. In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility. A sensor exchange or a transfer to another measured section is also possible without recalibration.
  • Small, fine, excellent: The Liebherr P78 sensor in conjunction with the Liebherr FMS moisture measuring installation has become indispensable for many industrial processes. The moisture measuring installation was invented in 1985 at the Bad Schussenried factory. Measurement by the Liebherr sensor system is based on the physical principle of capacitance determination in the high-frequency stray field. In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility. Once the sensor has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.
  • The CAN bus is used in on- and off-road applications, vehicles in the construction and agricultural sectors as well as in engines. The CAN bus is integrated in the sensor. The sensor meets critical EMC and environmental requirements. The signals are integrated and processed directly in the customer's control. The CAN bus signals communicate directly with the control apparatus. Measurement by the Liebherr sensor system is based on the physical principle of capacitance determination in the high-frequency stray field. In addition to their high precision and robustness, the sensor system from Bad Schussenried is characterised by its reproducibility. Each CAN sensor is individually calibrated and final tested.
  • The Liebherr in situ water content determination Litronic-FMS III-RMH12 is used to detect the water content (concentration determination) even in very low ppm ranges in emulsions such as diesel fuel, transmission, hydraulic, engine, roller bearing, transformer and turbine oil as well as in battery systems.  
Ga naar de bovenkant