• Draagbaar systeem APS

    Draagbaar gasconditioneringssysteem

    The portable system is suitable for variable, discontinuous and continuous operation. The components built into the system can be used for standard applications. For special requirements please ask us for other solutions.

    The heated sample line is to be mounted at the gas measuring inlet terminal inside the portable case. A ball-valve can be fitted to the inlet terminal of the portable system in order to calibrate analyser(s) with check gas.

    The amount of flow is determined by a sample gas diaphragm pump. The sample gas pump AMP 11P is activated automatically by means of an excess temperature contact on the cooler.

    Optional flow meters with integrated needle valve are available. The flow meters are built-in as the electronic controller and are visible from outside when the carrying case is closed. This unique microprocessor controlled Peltier cooler is a powerful designed dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1°C and 15°C. The gas cooler is equipped with an innovative heat exchanger system.

  • Draagbare Gasmonstername Probe APP

    met verwarmd filter (180°C)

    Due to various acid dew points at various applications the probe is heated up to 180°C.

    A filter element of 150mm is integrated, suitable for most applications up to 1g dust/m3. A significant advantage is that this filter is replaceable without dismounting the probe. With the filter element of 150mm length this probe is suitable for most applications up to 1g dust/m3; with the blow-back function dust loads of up to 10g/m3 can be handled.

    Calibration gas can be injected directly into the probe through the calibration gas connection according to EN14181 (regulation for calibration of emission monitoring systems) that enables calibration gas feeding via the filter element of the gas sample probe. The use of the optional high-flow check valve type APP 200 is recommended.

    The portable gas sample probe series APP is a perfect completion to the Ankersmid portable gas conditioning system series APS 303/313. Both devices can easily be connected together by the Ankersmid heated sample line type AHL205/025 with the incorporated innovative Quick-Lock System which guarantees a fast and reliable connection.

    Using this heated line the probe's electrical power is then fed to the probe via the feed line integrated within the sample line. To avoid cooling-down and condensation of sample gas in the extraction area, the heated sample probe tube type AST 301 is available.

  • Ankersmid Ambient Air Filters AAF 051 / AAF 052 / AAF 053 are used for the filtration of ambient air in gas monitoring systems.

    The main applications are in ambient air monitoring and in air conditioning systems.

  • Adsorptiefilter type AAM

    voor adsorptie van interfererende componenten

    Ankersmid Universal Filters are known as a reliable technique for the adsorption of components in a gas stream that cause interferences in the gas measurement.

    The design of the filter and filter housing ensures that any liquids present in the gas will be separated and collected in the bottom of the filter-housing.

    The AAM series are based on the elements of the AUF universal filter series.

    Due to its universal standard design, the filters can be used with various adsorption cartridges and, if needed, also be fitted with a liquid sensor.

  • The Ankersmid Humidifier controls the humidity of the gas sample stream. The Humidifier is used to wet calibration gases to ensure these gases undergo an identical cycle through the conditioning set-up.

    In this set-up, the calibration gases enter the cooler saturated at a stable dew point. Calibration gases with water-soluble components must not be passed through the humidifier.

  • The Ankersmid wash bottle serves different purposes. First of all, the wash bottle can wash out sample gases. The second application is its role in maintaining a constant pressure upstream of the analyzer by establishing a constant differential pressure with respect to the atmosphere by using the second inlet.
  • Aerosolfilter type AFP

    voor filtreren van vloeibare deeltjes

    The Ankersmid fluid particle filter or coalescence filter is suitable for filtration of fluid particles of all types and is recommended for sample gases with an acid dew point above 100 °C. Application examples are measurements in flue gas of heavy oil and black coal combustions.

    The filter separates the aerosols (very fine fluid particles) which still pass the gas cooler. The most effective position of the filter is downstream the sample conditioning close to the flow meter of the analyser. For additional system protection we provide the version with integrated hydrophobic diaphragm, working as a liquid stop.

  • The APF front panel mounting reliably extra-fine filters solids, in particular very fine particles, from the gas stream for gas conditioning applications. The APF uses a very fine, deep-acting filter element that removes particles larger then 100 nanometer from the gas stream. The large filter surface of the cylindrical filter element guarantees reliable extra-fine filtration and a long service life with low pressure drop.

    The APF extra-fine filter was primarily developed for 19" front-plate mounting equipment, as is evident from the APF’s small size that is suited to flat-design equipment

  • The ALS liquid-stop protects analyzers against an inrush of liquids from the gas conditioning unit into the analyzer.

    This avoids major damages of the analyser.

    The best position of the liquid is behind the gas conditioning unit, and before the flow meter going to the analyser.

  • iFID Mobile

    Draagbare Vlamionisatiedetector voor continue CxHybewaking

    Draagbare Vlamionisatiedetector

    De vlamionisatiedetector (FID) meet de totale koolwaterstofconcentratie in industriële en laboratoriumomgevingen. Door zijn lichtgewicht en compacte afmetingen is hij speciaal gemaakt voor dagelijks wisselende meetpunten of kortstondige metingen.
  • iFiD Rack

    19" rack vlamionisatiedetector voor continue CxHy bewaking

    19" Rack vlamionisatiedetector voor continue CxHy bewaking

    De stationaire vlamionisatiedetector (FID) iFiD Rack is ontworpen voor stack monitoring, proces controle alsook voor VOC meting. Het volledige gaspad is verwarmd op 300°C, vandaar we kunnen spreken van een hoge temperatuur FID.
  • iFID Wall

    Outdoor Vlamionisatiedetector iFiD voor continue CxHy bewaking

    Outdoor Flame-Ionisation-Detector iFiD Mobile for continuous monitoring

    The stationary Flame-Ionisation-Detector (FID) iFiD Wall is made for rough conditions and field installations. This unit measures the Total Hydrocarbon concentration especially in heavy industrial environment or freeair installations with small weatherprotection. The stainless steelhousing with a protection class IP65 gives the analyser a strong shelter all year long.
  • iFID Shed

    19" Rack Flame-Ionisation-Detector iFiD SHED for continuous monitoring

    19" Rack Flame-Ionisation-Detector iFiD SHED for continuous monitoring

    The stationary Flame-Ionisation-Detector (FID) iFiD SHED was designed as a 19" Rackunit. This analyzer is designed to measure volatile organic compounds in different sized SHED-chambers. The device is available in a bypass circuit version and an extraction version. The special advantage of the extraction version is a sample flow of only 12-15ml per minute. The whole gaspath is heated to 200°C and with its unique Pyrolysis cleaning system you can clean easily and save service costs.
  • iFID Dual

    Continuous monitoring of two parallel channels

    19" RackFlame-Ionisation-Detector iFiD Rack for continuous monitoring of 2 channels parallel

    The stationary Flame-Ionisation-Detector iFiD Dual is designed for measuring at two points with one unit. This saves money in comparison to a 2 unit solution. The channels are separated from each other and so you can permanently measure high and low concentrations paralell without switching procedure.
  • nCLD EL S

    NO / NOx - 5 ppm –5’000 ppm

    ECO PHYSICS nCLD EL S

    Gas Analyzer The nCLD EL S is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL S is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data. connects to other instruments’ data.
  • nCLD 66 Y

    NO / NOx - 50 ppb – 25’000 ppb

    ECO PHYSICS nCLD 66 Y

    Gas Analyzer The nCLD 66 Y is the next generation in single-channel ambient air monitoring instrumentation. Unique in speed and precision, the nCLD 66 Y is modular designed and capable of sequentially measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen oxide based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.