• The heated sampling system is a combination of a heated sample line and a heated sample filter. The sample line is 500mm long; the filter element can be replaced very quick with the bayonet lock. Beside the very precisious and constant regulation of the line and filter temperature, there is a separate controll point fort he temperature at the filterinlet, where you have an information of the exhaust gas temperature. Also the calibration gas (prewarmed) can directly connected with the unit. The thermocouple is available as PT 100 or NiCrNi.
  • Heated solenoid valve

    for SHED chamber

    Modell iFiD SHED

    The heated solenoid-valve prevents dilution or increase of the measurement gas concentration by giving up zero gas as well as test gas during or before the shed test measurement.
  • The heated 3-way solenoid valve is made for switching 2 heated lines on one analyzer. Beside this there is a second outlet for IR-analyzers or other analyzers built in.
  • The filterinlet model iFiD Filter is a flashbackable filterunit for all heated Testa Samplegasfilters. The filter is usable for exhaust gas from engines as well as for emmission measuring tasks.
  • Backwash M2

    Filter iFiD
    The heated prefilter model iFiD Backwash M2 is a samplegasfilter which can be flushbacked. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Backwash M1

    Filter Model iFiD
    The heated prefilter model iFiD Filter Backwash M1is a samplegasfilter which can flushbacked with an electronic solenoid valve. This valve can controll the pressure air (flushbackair) and the sample gas. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Heated Prefilter

    Model iFiD Filter XL
    The heated prefilter model iFiD FIlter XL is a samplegasfilter for the high temperature applications with a permanent temperature of 300°C. The filter is very stable with the temperature level you preselect, and also in permanent operation. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of + 1%.
  • The heated prefilter model iFiD Filter is a gasfilter for the high temperature applications who need a permanent temperature up to 300°C. The filter is very stable with the temperature level you can preselected. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of +-1%.
  • The gasstation is fitted with all supplygases who are necessary for a FID measurement. Hydrogen as the fuel gas, nitrogen as zerogas and propane as the calibration gas are available in the one liter bottles who allows a very good handling in mobile measurement. The FID can be connected via teflon hoses and quick connectors.
  • The heated transferline is made of a stainless steal tube with soldered heater. This construction is unique in relation to other lines and is guarantee for a very good heattransfer. Especially in cases of alternating process temperatures, the sample temperature can stabilized at preselected level. A Low-Cost-Version is available with simple teflon hose.
  • The air purifier CAP 15 and air purifier CAP 30 produces clean and hydrocarbon-free air out of normal compressed air. The Pt/Pd-catalyst convert by catalytical total-oxidation at 370°C all hydrocarbons inclusive methane (CH4) into carbondioxyde (CO2) and water (H2O). Hydrogen (H2) and carbonmonoxyde (CO) will be removed quantitatively.The produced air quality ist constantly free of hydrocarbons and better than sythetic air from gas bottles of class 5.0 (refering to organic components).On account of the high gas purity, the air purifier CAP 15/30 are used for FID-measuring systems as combustion air and as zero gas
  • LaserGas™ III Ultra

    Voor toepassingen met zeer lange padlengtes en hoge gasconcentraties

    LaserGas™ III Ultra

    It uses the innovative baseline-insensitive TDLAS technique specifically designed for combustion analysis. The Ultra simultaneously meets the requirements of combustion control and safety. That is, high measurement accuracy and high dynamic range with simultaneous real-time measurement capability. Applications with very long path lengths and high gas concentrations are no problem for the Ultra. Thanks to the baseline insensitivity and the use of the proprietary IROSS signal processing, high measurement accuracy is achieved even with complex gas mixtures. LaserGas™ III Ultra CO in combination with LaserGas™ III O2 are a perfect combination for proper combustion control and safety.
  • T-Flens oplossing

    Voor montage van twee LaserGas™ III (Ultra) analysatoren op één enkel paar flenzen
    De T-flensoplossing van NEO Monitors is ontworpen om twee LaserGas™ III (Ultra)-analysatoren op één paar flenzen te plaatsen. Dit maakt metingen met lange optische padlengtes mogelijk, terwijl de benodigde ruimte en installatiekosten worden verminderd. Door het compacte ontwerp zijn de spoelvereisten zeer laag, wat de bedrijfskosten verlaagt. Dankzij een zeer configureerbaar ontwerp kan de T-flensoplossing eenvoudig worden aangepast aan verschillende configuraties en toepassingen; individuele analysers kunnen eenvoudig worden vervangen. De certificeringen van de respectievelijke analysers, b.v. EX-d of SIL2 blijven behouden bij gebruik in de T-flensoplossing. Een typische toepassing is verbrandingsanalyse waarbij de T-Flange in combinatie met een LaserGas™ III O2 en een LaserGas™ III CO Ultra de perfecte oplossing is voor procesoptimalisatie en veiligheid.
  • ZFDM-4 Flue Gas Dust Monitor

    Accurate back scattering

    dust monitor

    Robust and accurate back scattering dust monitor for rough industrial installations

    QAL1 certified continuous monitoring of particulates concentration. Thanks to the backscattering technology, the LED light beam provides an accurate measurement (insensitive to ambient light). The self-checking anti-fouling functions and the continuous automatic correction system correct possible measurement drifts. This device is suitable for small and medium diameter ducts, for very low and medium dust concentrations as well as for light to dark coloured particles.
  • ZPA

    5 components analyser - NDIR single beam

    ZPA is best suited to the measurement of exhaust gas from refuse incinerators, boilers, and various industrial furnaces.

    NO, SO2, CO2, CO, CH4 Non-dispersion infrared-ray absorption methodSingle  light  source  and  single  beams  (single  beam system) O2 : Galvanic fuel cell O2 analyzer (built-in) paramagnetic O2 analyzer (built-in), or zirconia O2 analyzer (externally installed TYPE: ZFK7)
  • Fuji Electric Extractive Gas Analyzers for process control and continuous measurement of stack emissions. Their QAL1 certification guarantees high performance and regulatory and normative compliance. Reliable and precise, their design quality guarantees 24-hour operation in difficult environments such as smoke from industrial chimneys. Robustness reduces maintenance costs and increases the availability of boilers and equipment. Extractive measurement consists of taking a gas flow from the chimney or the gas pipe via a sampling probe and conveying it to the gas analyzer. The gas is sampled, treated in order to ensure optimal conditions for gas measurement.