• Portable Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
  • Portable Multicomponent IR Analyzer

    CO, CO2, CH4, CnHm,O2, H2 + BTU index (gas calorific value)
    The analyzers can measure the concentration of multiple gases simultaneously. It is based on the single source dual-beam non-dispersion infrared (NDIR) method for CO, CO2 , CH4 , CnHm, H2S , SO2 and a micro-TCD (Thermal Conductivity Detector) gas sensor for H2 and O2 by fuel cell method. The analyzers have a digital pulsable infrared source and dual-beam systems
  • PFM 92 C

    Filter monitoring device
    • filter monitor for in-situ dust measurement
    • compact device consisting exclusively of the probe
    • suitable for the construction of filter monitoring systems
  • PFM 14 K

    Mobiel systeem voor tijdelijke, tribo-elektrische in-situ filter monitoring van uitlaatgassen
    • mobile filter diagnosis unit for triboelectric in-situ monitoring of dust emissions
    • measuring probe with variable length to  adapt to the local conditions
    • immediate clean gas dust content monitoring after the dust collectors
    • offline power supply by power bank
    • integrated recorder
  • PFM 14

    Filter monitoring device
    • filter monitor for in-situ dust measurement
    • with separate operating unit
    • display showing the measured value in mg/m³ or line diagram
  • PFM 13 C EX

    Filter monitoring device
    • continuous, tribo-electric in-situ filter monitoring device with EC-Type Examination Certificate (IBExU19ATEXB008 X)
    • approved for Ex II 3D Ex ic tc IIIC T80 °C Dc
    • suitable for installations in hazardous areas of zone 22
    • no separate power supply necessary (2-wire transmitter)
    • two probe lengths available (300 and 500 mm)
  • PFM 13 C

    filter monitor for in-situ dust measurement
    • filter monitor for in-situ dust measurement
    • compact device
    • suitable for the construction of filter monitoring systems
  • PFM 13

    filter monitor for in-situ dust measurement
    • filter monitor for in-situ dust measurement
    • compact device with display
    • suitable for the construction of filter monitoring systems
  • PFM 06 ED

    Continuous, optical extractive measurement of dust contents in wet and sticky exhaust gases
    • extractive optic dust concentration measurement
    • measurement in wet, sticky exhaust gas conditions
    • optical dust sensor
    • suitability tested according to EN 15267-3 (QAL1)
    • approved for installations according to IED
  • PFM 02 HB

    Residual dust sensor
    • residual dust sensor for wood processing industry with the EC-type examination certificate
    • compact device
    • suitable for the construction of filter monitoring systems
  • PFM 02 EX

    Filter monitoring device
    • filter monitor for in-situ dust measurement with EC-Type Examination Certificate (IBExU04ATEX1249 X)
    • approved for Ex II 1 / 3D Ex ia / tc IIIC T74 ° C Da / Dc and Ex II 3G Ex nA IIC T4 Gc ic
    • compact device
    • display showing the measured value in mg/m³ or in line diagram
  • PFM 02

    Filter monitoring device
    • filter monitor for in-situ dust measurement
    • compact device
    • display showing the measured value in mg/m³ or in line diagram
  • Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
  • nCLD EL²

    NO , NO2 , NOx - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD EL²

    Modular Gas Analyzer The nCLD EL2 analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD EL2 is modular designed and capable of simultaneously measuring NO, NO2 and NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD EL S

    NO / NOx - 5 ppm –5’000 ppm

    ECO PHYSICS nCLD EL S

    Gas Analyzer The nCLD EL S is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL S is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data. connects to other instruments’ data.
  • nCLD EL

    NO / NOx - 0.5 ppm -500 ppm

    ECO PHYSICS nCLD EL

    Gas Analyzer The nCLD EL is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
Ga naar de bovenkant