• FID 2000MP SHED

    Connection for 4 calibration gases

    Mini/Micro-SHED

    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in SHED-chambers of different sizes. For applications beginning of 2,5m3 we recommend to measure in a heated circular system to get a response time near to real changes of concentration in the chamber. For smaller chambers, we have developed a special FID-analyzer with a sample flow of 12ml/min. These two types of analyzers optimizethe air change rateover the extraction rate.
  • ProMass Desktop

    closed ion source and 0-200amu range
    Laboratory QMS Gas Analyser For laboratory applications across many fields of research, the ProMass analyser can be provided in a desktop format. With integrated vacuum system – turbo molecular drag pump and diaphragm roughing pump – ProMass can be operated straight away. A heated capillary of various materials (stainless steel, PEEK, PTFE, borosilicate) is provided included with temperature control of the capillary. Total pressure gauge, analogue and digital inputs, sample pressure and temperature controlled chamber bake-out are all built-in features to give complete sample control.   ProMass uses Protea’s proven RGA quadrupole mass spectrometer that is provided as standard with dual Faraday/SEM detector, closed ion source and 0-200amu range for the analytically focused applications of the ProMass desktop system.
  • Ideally suited to semiconductor production processes, ambient air measurements, leak testing and quality testing for the food industry, the 19” mountable ProMass analyser is a complete process tool. ProMass can be provided with fully integrated vacuum system, or for demanding process applications, an external backing pump is provided – particularly for hazardous area applications. Protea will integrate the ProMass analyser with our sampling control system and industrial analyser controller for a complete measurement system. This can be provided to measure from multiple sample locations is quick succession.
  • ProMass Transportable

    Draagbare Quadrupole Mass Spectrometer (QMS) analyser
    For use in the field, ProMass can be provided in a rugged mobile case. With a vacuum start-up in less than 40mins, ProMass can be deployed quickly. Using either the simple PAS-Pro software for unattended operation, or the more complex PAS software for investigation work, ProMass Transportable can give real-time, wide range measurements of any gas.
    • Leak testing (sniffer mode)
    • Syngas analysis
    • Environmental testing
    • Dissolved gas analysis (with membrane inlet)
    • Gas impurity testing
  • The Protea 2000 emissions monitoring system is approved forthe analysis of exhaust gases from the engines and boilers of ships and offshore rigs. Robust and with proven reliability, up to six gases can be measured including SO2,CO2 The Protea 2000 emissions monitoring system comprises up to 8 exhaust mounted analysers, each with automatic verification facilities. Emissions data from the entire system is securely managed and displayed at a dedicated Classification Society approved panel PC, with outputs to networks, control systems, and reporting facilities.
  • ZKJ

    5 components analyser - NDIR dual beam

    Ideal for controlling polluting emissions

    Uses a highly sensitive mass flow meter as a detector. Simultaneous and continuous measurement of 5 gases : CO2  -  CO  -  CH4  -  NOX  -  SO2  -  O2  -  NO  -  N2O
  • ZRE

    5 gas NDIR analyser - Single beam
    Compact and easy to use Excellent stability over time No influence of humidity on the measurement Automatic calibration, communication and alarms Simultaneous and continuous measurement of the concentration of 5 gases: CO - CO2 - NO - NOX - SO2 - CH4 - O2
  • ATEX in-situ oxygen analysers

    Ex-proof in situ zirconia oxygen analyzer for combustion control
    Ex-proof in situ zirconia oxygen analyzer for combustion control
    The oxygen measurement enables the control of burner fuel/air ratios to ensure combustion efficiency and process safety. Fuji Electric O2 Analyser is adapted to be installed in hazardous areas and to withstand critical environments as:
    • Refinery process heaters
    • Petrochemical reactor furnaces
    • Industrial large scale boilers
  • Hydrogen Analysers

    Thermal Conductivity Gas Analyser ZAF and ZAFE
    Reliable process control for furnaces, metal industry, semiconductor and gas separation. The analyser continuously measures the concentration of gases such as H2, He, and Ar with high stability. It is also available in a version for hazardous areas (for countries outside the European Union): ZAFE certified Ex NEPSI.
  • In-situ zirconia oxygen gas analysers

    Fast response (4–7 seconds)
    Optimization of combustion efficiency and compliance with environmental standards Ideal for combustion control in boilers, incinerators and furnaces. Lowering CO₂, SOx, and NOx emissions while saving energy This oxygen analyser is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion management and control, such as garbage incinerators and smallest to largest sized boilers, as combustion controllers, achieving a significant energy-saving effect.
  • PFM 06 ED

    Continuous, optical extractive measurement of dust contents in wet and sticky exhaust gases
    • extractive optic dust concentration measurement
    • measurement in wet, sticky exhaust gas conditions
    • optical dust sensor
    • suitability tested according to EN 15267-3 (QAL1)
    • approved for installations according to IED
  • FDS 15

    real-time measurement (PM10 or PM2.5)

    Optical sensor for continuous measurement and monitoring of fine dust contents indoor and outdoor.

    • optical sensor for continuous measurement and monitoring of fine dust concentrations (PM10, PM2.5)
    • smart, robust, network-capable
    • simple unit design
    • installation without any special tools
  • FDS 17

    simultaneous real-time measurement of PM10/ TSP and PM2.5
    • optical sensor for continuous, simultaneous measurement and control of fine dust contents PM10/TSP and PM2,5
    • patented zero point control by electrostatic precipitator
    • smart, robust, network-capable
    • simple unit design
    • installation without any special tools
  • FDS 17 m

    Simultane real-time meting van PM10 & PM2.5
    • simultaneous real-time measurement of PM10 & PM2.5
    • based on optical sensor, active suction & patented electrostatic precipitator for zero point setting
    • flexible use - indoors & outdoors -
    • portable case with offline power supply by power bank
    • including data logger for storage of measuring values
  • FDS 18

    Real-time measurement of PM2,5 
    • real-time measurement of PM2,5
    • Monitoring of fine dust concentrations in ambient air and/or at workplaces
    • optical sensor including fitting with clip system, therefore easily exchangeable
    • active and automatic zero point setting
    • active air suction
    • Integrated pre-separator for particles > 2,5 µm
    • noiseless operation
    • network-compatible
  • PFM 14 K

    Mobiel systeem voor tijdelijke, tribo-elektrische in-situ filter monitoring van uitlaatgassen
    • mobile filter diagnosis unit for triboelectric in-situ monitoring of dust emissions
    • measuring probe with variable length to  adapt to the local conditions
    • immediate clean gas dust content monitoring after the dust collectors
    • offline power supply by power bank
    • integrated recorder
  • GMD 13

    Gravimetrisch meetsysteem
    • patented world innovation: Sampling and weighting in one system on site!
    • intelligent system for isokinetic dust and fine particles measurements in exhaust air ducts and stacks
    • acquisition of all necessary gas boundary parameters (humidity of the sample gas, velocity in exhaust gas channel, temperature, pressure)
    • pivotable graphic display for more convenient operations
  • GMD 12

    Gravimetrisch meetsysteem
    • intelligent system for isokinetic dust and fine particles measurements in exhaust air ducts and stacks
    • acquisition of all necessary gas boundary parameters (humidity of the sample gas, velocity in exhaust gas channel, temperature, pressure)
    • pivotable graphic display for more convenient operations
  • PFM 14

    Filter monitoring device
    • filter monitor for in-situ dust measurement
    • with separate operating unit
    • display showing the measured value in mg/m³ or line diagram
  • PFM 13

    filter monitor for in-situ dust measurement
    • filter monitor for in-situ dust measurement
    • compact device with display
    • suitable for the construction of filter monitoring systems
  • PFM 13 C

    filter monitor for in-situ dust measurement
    • filter monitor for in-situ dust measurement
    • compact device
    • suitable for the construction of filter monitoring systems
  • PFM 13 C EX

    Filter monitoring device
    • continuous, tribo-electric in-situ filter monitoring device with EC-Type Examination Certificate (IBExU19ATEXB008 X)
    • approved for Ex II 3D Ex ic tc IIIC T80 °C Dc
    • suitable for installations in hazardous areas of zone 22
    • no separate power supply necessary (2-wire transmitter)
    • two probe lengths available (300 and 500 mm)
  • PFM 02

    Filter monitoring device
    • filter monitor for in-situ dust measurement
    • compact device
    • display showing the measured value in mg/m³ or in line diagram
  • PFM 02 EX

    Filter monitoring device
    • filter monitor for in-situ dust measurement with EC-Type Examination Certificate (IBExU04ATEX1249 X)
    • approved for Ex II 1 / 3D Ex ia / tc IIIC T74 ° C Da / Dc and Ex II 3G Ex nA IIC T4 Gc ic
    • compact device
    • display showing the measured value in mg/m³ or in line diagram
  • PFM 02 HB

    Residual dust sensor
    • residual dust sensor for wood processing industry with the EC-type examination certificate
    • compact device
    • suitable for the construction of filter monitoring systems
  • PFM 92 C

    Filter monitoring device
    • filter monitor for in-situ dust measurement
    • compact device consisting exclusively of the probe
    • suitable for the construction of filter monitoring systems
  • GPR-1000/1100/2000/ 3500 MO

    Voor steekproeven ter plaatse van PPM tot 100% zuurstof
    Deze robuuste draagbare instrumenten zijn geschikt voor sporen zuurstofmetingen van 0,1 ppm tot zuiverheid toepassingen bij 100% zuurstof en delen dezelfde geavanceerde sensortechnologie als de online proces zuurstof analysatoren, waardoor u kunt vertrouwen op hun betrouwbaarheid en nauwkeurigheid. Het concept van Analytical Instruments, waarbij dezelfde HMI en menustructuren worden gebruikt voor draagbare en online analysers, maakt het voor operators uiterst eenvoudig om beide soorten instrumenten op hun locatie te gebruiken zonder dat er extra training nodig is.
  • AII GPR-1200/3500

    Gemakkelijke tracering en meting van zuivere zuurstof
    De zeer nauwkeurige draagbare zuurstofanalysatoren van Analytical Industries zijn bedoeld voor toepassingen die op verschillende gedefinieerde meetpunten moeten worden gecontroleerd. Het GPR-3500-model heeft een compacte, robuuste behuizing en bevat roestvrijstalen onderdelen die in contact komen met de vloeistof, geïntegreerde debietmeters en naaldventielen. Het meet de zuiverheid voor inerte gassen, kooldioxide en zuurstof. De GPR-1200 compacte draagbare zuurstofanalyser voor sporen heeft een 4-wegklep die een gasmonster in de sensor opvangt. Dit maakt snellere zuurstofmeettijden mogelijk bij het verplaatsen van punt naar punt in een proces en beschermt ook sporenzuurstofsensoren tegen voortijdige uitputting als gevolg van blootstelling aan omgevingszuurstofniveaus om hun levensduur te verlengen. Dit alles zorgt voor een zuinige werking en lage eigendomskosten voor deze toonaangevende reeks draagbare zuurstofanalysers.
  • GPR 1600/2600/3100

    Percent and PPM O2 Monitoring in Bulk Gases
    Ons assortiment zuurstofanalysatoren is ontworpen om gas te bewaken dat wordt geproduceerd of gebruikt in industriële processen waar zuurstofspoor van lage deeltjes per miljoen tot pure O2 nauwkeurig moet worden gemeten. Door gebruik te maken van de hoogwaardige galvanische zuurstofsensoren van AII zijn deze geavanceerde instrumenten eenvoudig te gebruiken met een gemeenschappelijke HMI en menustructuur voor het hele bereik. Operators hoeven slechts één instrument te leren voor meerdere gasanalysetoepassingen bij verschillende zuurstofniveaus. Verkrijgbaar als bench-, 19 "rack-, panel- en wandmontage voor flexibele installatie.
  • The UT-3000 Ng mobile is specifically designed to measure ultratrace amounts of mercury in natural gas at differing sites. The system, for example, thus allows to monitor the efficiency of different Mercury Removal Units (MRUs) in natural gas processing plants.
  • Portable Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
  • Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
Ga naar de bovenkant