-
Outdoor Flame-Ionisation-Detector iFiD Mobile for continuous monitoring
The stationary Flame-Ionisation-Detector (FID) iFiD Wall is made for rough conditions and field installations. This unit measures the Total Hydrocarbon concentration especially in heavy industrial environment or freeair installations with small weatherprotection. The stainless steelhousing with a protection class IP65 gives the analyser a strong shelter all year long. -
19" Rack Flame-Ionisation-Detector iFiD SHED for continuous monitoring
The stationary Flame-Ionisation-Detector (FID) iFiD SHED was designed as a 19" Rackunit. This analyzer is designed to measure volatile organic compounds in different sized SHED-chambers. The device is available in a bypass circuit version and an extraction version. The special advantage of the extraction version is a sample flow of only 12-15ml per minute. The whole gaspath is heated to 200°C and with its unique Pyrolysis cleaning system you can clean easily and save service costs. -
19" RackFlame-Ionisation-Detector iFiD Rack for continuous monitoring of 2 channels parallel
The stationary Flame-Ionisation-Detector iFiD Dual is designed for measuring at two points with one unit. This saves money in comparison to a 2 unit solution. The channels are separated from each other and so you can permanently measure high and low concentrations paralell without switching procedure. -
Total Hydrocarbon Analyser
The Flame-Ionisation-Detector 2010 T measures Total HydroCarbon (THC) in a wide range of applications like catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases.By it`s little weight and it`s compact dimensions, he is especially made for daily changing measuring points or shorttime measurings campains. -
19" rack version Flame-Ionisation Detector FID 1230
The Flame-Ionisation-Detector FID1230 Module measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy. Because of the module system, there is an optimal configuration for every measurement-task under profit aspects possible. All modules can be fit in at any time. -
High-Temperature Analyzer for Exhaust gas measurement
The flame-ionization-detector 1230I-H can measure the sum of total hydrocarbon concentrationin applications like cold starts of engines (down to–40°Cambient temperature), inwoodburning systems and also at engine test units (especially oil-and gasburners, airplaneengines etc.) Our high temperature heated lines with a operation temperature of 400°C are made additionally for measurements of highboiling hydrocarbons. For the sample-gas pickup we have built some prefilters who are able to hold back the tar compounds. -
Wall mount Flame-Ionisation-Detector 3001W
The Flame-Ionisation-Detector 3001W measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. Because of its swingable housing, there is an easy installation and optimal accessibility guaranteed. This wallmounted analyser is a compact, robust weatherproofed version. The environmental protectionmode is IP65. -
Methaan/THC Analysator
De draagbare verwarmde FID 2010 NMHC van TESTA meet met zijn ingebouwde NMHC-cutter de methaanconcentratie (alleen methaan) en na overschakeling op een ander kanaal ook de THC in een breed scala aan toepassingen zoals bewaking van schoorsteengasemissies, bewaking van omgevingslucht, monitoring van thermische reactor- en verbrandingsemissies en ook uitlaatgassen van voertuigen. De monitoring is continu met een hoge nauwkeurigheid, gevoeligheid en stabiliteit. Alle componenten die in contact komen met het monster worden volledig verwarmd op 200°. -
Methane only / Total Hydrocarbon THC monitoring system (Change-over switch) The 19” Flame-Ionisation-Detector (FID) 1230NMHC measures with its built-in NMHC-Cutter the methane concentration (methane only) and after switching to THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability.
-
The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in a wide range of applications like all kind of emission control, catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air (immissions), solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy.
-
Mini/Micro-SHED
The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in SHED-chambers of different sizes. For applications beginning of 2,5m3 we recommend to measure in a heated circular system to get a response time near to real changes of concentration in the chamber. For smaller chambers, we have developed a special FID-analyzer with a sample flow of 12ml/min. These two types of analyzers optimizethe air change rateover the extraction rate. -
The stationary Flame-Ionisation-Detector (FID) iFiD NMHC measures with its built in NMHC Cutter the methane concentration and parallel in a second channel also the THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability. All components which come in contact with sample are fully heated at 200°.
-
The air purifier CAP 15 and CAP 30 produces clean and hydrocarbon-free air out of normal compressed air. The Pt/Pd-catalyst convert by catalytical total-oxidation at 370°C all hydrocarbons inclusive methane (CH4) into carbondioxyde (CO2) and water (H2O). Hydrogen (H2) and carbonmonoxyde (CO) will be removed quantitatively.The produced air quality ist constantly free of hydrocarbons and better than sythetic air from gas bottles of class 5.0 (refering to organic components).On account of the high gas purity, the air purifier CAP 15/30 are used for FID-measuring systems as combustion air and as zero gas.
-
The air purifier CAP 15 and air purifier CAP 30 produces clean and hydrocarbon-free air out of normal compressed air. The Pt/Pd-catalyst convert by catalytical total-oxidation at 370°C all hydrocarbons inclusive methane (CH4) into carbondioxyde (CO2) and water (H2O). Hydrogen (H2) and carbonmonoxyde (CO) will be removed quantitatively.The produced air quality ist constantly free of hydrocarbons and better than sythetic air from gas bottles of class 5.0 (refering to organic components).On account of the high gas purity, the air purifier CAP 15/30 are used for FID-measuring systems as combustion air and as zero gas
-
The heated transferline is made of a stainless steal tube with soldered heater. This construction is unique in relation to other lines and is guarantee for a very good heattransfer. Especially in cases of alternating process temperatures, the sample temperature can stabilized at preselected level. A Low-Cost-Version is available with simple teflon hose.
-
The gasstation is fitted with all supplygases who are necessary for a FID measurement. Hydrogen as the fuel gas, nitrogen as zerogas and propane as the calibration gas are available in the one liter bottles who allows a very good handling in mobile measurement. The FID can be connected via teflon hoses and quick connectors.
-
The heated prefilter model iFiD Filter is a gasfilter for the high temperature applications who need a permanent temperature up to 300°C. The filter is very stable with the temperature level you can preselected. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of +-1%.
-
The heated prefilter model iFiD FIlter XL is a samplegasfilter for the high temperature applications with a permanent temperature of 300°C. The filter is very stable with the temperature level you preselect, and also in permanent operation. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of + 1%.
-
The heated prefilter model iFiD Filter Backwash M1is a samplegasfilter which can flushbacked with an electronic solenoid valve. This valve can controll the pressure air (flushbackair) and the sample gas. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
-
Heated Inlet Protection Filter model number 1035 is made for filtering the particles from a size of 5μ and bigger out of the samplegas. The Operation time of an Testa-FID without a build in filter (Model 123) can lengthened several times, because this fine filter helps to minimize the change of the sample capillary, the cleaning of the pump and minimize the maintenance. All the spikes you can see without filter are eliminated with our model 1035.
-
The heated sampling system is a combination of a heated sample line and a heated sample filter. The sample line is 500mm long; the filter element can be replaced very quick with the bayonet lock. Beside the very precisious and constant regulation of the line and filter temperature, there is a separate controll point fort he temperature at the filterinlet, where you have an information of the exhaust gas temperature. Also the calibration gas (prewarmed) can directly connected with the unit. The thermocouple is available as PT 100 or NiCrNi.