• GMD 13

    Gravimetrisch meetsysteem
    • patented world innovation: Sampling and weighting in one system on site!
    • intelligent system for isokinetic dust and fine particles measurements in exhaust air ducts and stacks
    • acquisition of all necessary gas boundary parameters (humidity of the sample gas, velocity in exhaust gas channel, temperature, pressure)
    • pivotable graphic display for more convenient operations
  • GMD 12

    Gravimetrisch meetsysteem
    • intelligent system for isokinetic dust and fine particles measurements in exhaust air ducts and stacks
    • acquisition of all necessary gas boundary parameters (humidity of the sample gas, velocity in exhaust gas channel, temperature, pressure)
    • pivotable graphic display for more convenient operations
  • The Ankersmid Humidifier controls the humidity of the gas sample stream. The Humidifier is used to wet calibration gases to ensure these gases undergo an identical cycle through the conditioning set-up.

    In this set-up, the calibration gases enter the cooler saturated at a stable dew point. Calibration gases with water-soluble components must not be passed through the humidifier.

  • Gas Sample Probe Series ASP

    Verwarmd, modulaire opbouw met vele opties
    Due to its modular design and various options, the Ankersmid heated sample probe filters cover the widest range of applications. With a choice of different lengths of heated filter body, a filter element of 150mm length, suitable for most applications up to 1g dust/m3 can be integrated. 180mm filters with a larger filter surface are used for applications up to 4g dust/m3; with the blow- back function dust loads of up to 10g/m3 can be handled. The 500mm model filter of the ASP 1500 has a capacity for dust up to 10g/m3. When this type is equipped with blow-back option, it handles up to 20g/m3. For even higher dust loads, a primary filter is positioned on top of the first filter. A significant advantage is that all filters are replaceable without dismounting the probe without using any tools and in the shortest possible time. Cleaning and exchanging of unheated sample tubes or preliminary top-filters can be affected by extracting the filter from the probe. The probe temperature is controlled by a microprocessor based PID-controller (optional with Modbus/RS485 communication). Alarm or fault contacts can be programmed and the temperature can be changed easily. The standard sensor is PT100, whereas a thermo-couple is standard for the high temperature version.
  • Flue Gas Humidity Monitors Delta-O2

    In-situ or extractive O2 + H2O monitors
    Continuous measurement of humidity in highly dusts loaded flue gas through dry and wet zirconia oxygen measurements. In-situ or extractive O2 + H2O monitors depending on the application. Perfect for combustion control of biomass boilers : industrial boilers, district heating.
    O2 DRY  -  O2 WET -  H2O
  • Microventuri based continuous monitoring of flue gas flow rate, pressure and temperature
    Designed for tough industrial applications with highly dusts loaded fl ue gas.
  • FL007

    Olie in water analyser
    The Kemtrak FL007 is a fiber optic probe based oil in water monitor. A state-of-the-art combined fluorescence and turbidity measurement assures reliable continuous monitoring of oil and hydrocarbon contamination in water. Mineral oils rich in aromatic content will fluoresce when illuminated with ultraviolet light. The intensity of this fluorescence is dependent upon the polyaromatic hydrocarbon (PAH) content of the oil. Typical oils that fluoresce include fuel oil, crude oil, hydraulic oil and transformer oil.
  • The filterinlet model iFiD Filter is a flashbackable filterunit for all heated Testa Samplegasfilters. The filter is usable for exhaust gas from engines as well as for emmission measuring tasks.
  • The heated prefilter model iFiD Filter is a gasfilter for the high temperature applications who need a permanent temperature up to 300°C. The filter is very stable with the temperature level you can preselected. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of +-1%.
  • FID 3001W

    Analytical section heated on 300°C

    Wall mount Flame-Ionisation-Detector 3001W

    The Flame-Ionisation-Detector 3001W measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. Because of its swingable housing, there is an easy installation and optimal accessibility guaranteed. This wallmounted analyser is a compact, robust weatherproofed version. The environmental protectionmode is IP65.
  • FID 2010 T

    Draagbare Vlam-Ionisatie-Detector FID 2010T voor continue monitoring van CxHy - Classic Line

    Total Hydrocarbon Analyser

    The Flame-Ionisation-Detector 2010 T measures Total HydroCarbon (THC) in a wide range of applications like catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases.By it`s little weight and it`s compact dimensions, he is especially made for daily changing measuring points or shorttime measurings campains.
  • FID 2010 NMHC

    Draagbare Methaan/CxHy Analyser

    Methaan/THC Analysator

    De draagbare verwarmde FID 2010 NMHC van TESTA meet met zijn ingebouwde NMHC-cutter de methaanconcentratie (alleen methaan) en na overschakeling op een ander kanaal ook de THC in een breed scala aan toepassingen zoals bewaking van schoorsteengasemissies, bewaking van omgevingslucht, monitoring van thermische reactor- en verbrandingsemissies en ook uitlaatgassen van voertuigen. De monitoring is continu met een hoge nauwkeurigheid, gevoeligheid en stabiliteit. Alle componenten die in contact komen met het monster worden volledig verwarmd op 200°.
  • FID 2000MP SHED

    Connection for 4 calibration gases

    Mini/Micro-SHED

    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in SHED-chambers of different sizes. For applications beginning of 2,5m3 we recommend to measure in a heated circular system to get a response time near to real changes of concentration in the chamber. For smaller chambers, we have developed a special FID-analyzer with a sample flow of 12ml/min. These two types of analyzers optimizethe air change rateover the extraction rate.
  • FID 2000 MP

    Analytical section heated on 200°C
    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in a wide range of applications like all kind of emission control, catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air (immissions), solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy.
  • FID 1230 NMHC

    Methane only / CxHy monitoring system (Change-over switch)
    Methane only / Total Hydrocarbon THC monitoring system (Change-over switch) The 19” Flame-Ionisation-Detector (FID) 1230NMHC measures with its built-in NMHC-Cutter the methane concentration (methane only) and after switching to THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability.
  • FID 1230 Module

    Vlam-Ionisatie-Detector 1230 Module voor continue monitoring van CxHy

    19" rack version Flame-Ionisation Detector FID 1230

    The Flame-Ionisation-Detector FID1230 Module measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy. Because of the module system, there is an optimal configuration for every measurement-task under profit aspects possible. All modules can be fit in at any time.
Ga naar de bovenkant