• Draagbare Gasmonstername Probe APP

    met verwarmd filter (180°C)

    Due to various acid dew points at various applications the probe is heated up to 180°C.

    A filter element of 150mm is integrated, suitable for most applications up to 1g dust/m3. A significant advantage is that this filter is replaceable without dismounting the probe. With the filter element of 150mm length this probe is suitable for most applications up to 1g dust/m3; with the blow-back function dust loads of up to 10g/m3 can be handled.

    Calibration gas can be injected directly into the probe through the calibration gas connection according to EN14181 (regulation for calibration of emission monitoring systems) that enables calibration gas feeding via the filter element of the gas sample probe. The use of the optional high-flow check valve type APP 200 is recommended.

    The portable gas sample probe series APP is a perfect completion to the Ankersmid portable gas conditioning system series APS 303/313. Both devices can easily be connected together by the Ankersmid heated sample line type AHL205/025 with the incorporated innovative Quick-Lock System which guarantees a fast and reliable connection.

    Using this heated line the probe's electrical power is then fed to the probe via the feed line integrated within the sample line. To avoid cooling-down and condensation of sample gas in the extraction area, the heated sample probe tube type AST 301 is available.

  • Draagbaar systeem APS

    Draagbaar gasconditioneringssysteem

    The portable system is suitable for variable, discontinuous and continuous operation. The components built into the system can be used for standard applications. For special requirements please ask us for other solutions.

    The heated sample line is to be mounted at the gas measuring inlet terminal inside the portable case. A ball-valve can be fitted to the inlet terminal of the portable system in order to calibrate analyser(s) with check gas.

    The amount of flow is determined by a sample gas diaphragm pump. The sample gas pump AMP 11P is activated automatically by means of an excess temperature contact on the cooler.

    Optional flow meters with integrated needle valve are available. The flow meters are built-in as the electronic controller and are visible from outside when the carrying case is closed. This unique microprocessor controlled Peltier cooler is a powerful designed dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1°C and 15°C. The gas cooler is equipped with an innovative heat exchanger system.

  • Mini Compressorkoeler type ACC

    voor tot maximum 2 gasstromen
    The ACC cooler offers precision, safety and long-term stability for extractive analytics. The very low gas dissolution rate is attained owing to the new cooler technology (Patents applied). Both the permanent separation of the condensate from the gas phase, as well as the shorter contact time of the gas in the system, plays important roles in reducing gas dissolution rates. The new cooler incorporates an advanced structural design with housing suitable for both wall-mounting (standard) and 19“-racks by using optional brackets. The coolers can be integrated into the analysis cabinet without empty space requirements at the side for a cooling air outlet. The design enables 1 or 2 heat exchangers to be incorporated either at the factory or at a later time, without any problem. The exchangers can be connected in series or parallel following customer requirements. An electronic system monitors the dew point and controls the integrated fan. A temperature alarm output is wired to the terminal block incorporated of the cooler housing for a safe connection without disassembling the cooler.

    Available for 230 VAC and 115 VAC power supply.

  • Ankersmid Universal Filters are known as a reliable technique for the separation of particles from gas, ensuring a flow of clean gas to the analyzer. Filter housings in a variety of materials and standard dimensions are available.

    The design of the filter and filter housing also ensures that any liquids present in the gas will be separated from the gas.

    Liquids are collected in the bottom of the filter-housing.

    Due to its universal standard dimensions and functionality, the filter elements can also be used with any commercially available filter housings.

    The filters are easily replaced without the use of any additional tools.

    Where needed, a liquid sensor or liquid drain can be installed at the bottom of the filter housing tube.

  • This unique microprocessor controlled Peltier Cooler has been designed with a powerful dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1 and 15°C. The condensate that is formed should be removed by a peristaltic pump, automatic drain or collection vessel.

    The heat exchanger is demountable and PFA®-coated.

    The digital controlled cooler has many control and warning features like programmable alarms, mA-output, digital inputs and Modbus or RS485 communication. The alarm status changes when the temperature deviates by • ± 3 °C from the set point.

    Available for 230VAC and 115VAC power supply.

  • Gas Sample Probe Series ASP

    Verwarmd, modulaire opbouw met vele opties
    Due to its modular design and various options, the Ankersmid heated sample probe filters cover the widest range of applications. With a choice of different lengths of heated filter body, a filter element of 150mm length, suitable for most applications up to 1g dust/m3 can be integrated. 180mm filters with a larger filter surface are used for applications up to 4g dust/m3; with the blow- back function dust loads of up to 10g/m3 can be handled. The 500mm model filter of the ASP 1500 has a capacity for dust up to 10g/m3. When this type is equipped with blow-back option, it handles up to 20g/m3. For even higher dust loads, a primary filter is positioned on top of the first filter. A significant advantage is that all filters are replaceable without dismounting the probe without using any tools and in the shortest possible time. Cleaning and exchanging of unheated sample tubes or preliminary top-filters can be affected by extracting the filter from the probe. The probe temperature is controlled by a microprocessor based PID-controller (optional with Modbus/RS485 communication). Alarm or fault contacts can be programmed and the temperature can be changed easily. The standard sensor is PT100, whereas a thermo-couple is standard for the high temperature version.
  • Compressorkoeler type ACC

    voor tot 4 maximum gasstromen

    The ACC cooler offers precision, safety and long-term stability for extractive analytics. The very low gas dissolution rate is attained owing to the new cooler technology (Patents applied). Both the permanent separation of the condensate from the gas phase, as well as the shorter contact time of the gas in the system, plays important roles in reducing gas dissolution rates.

    The new cooler incorporates an advanced structural design with housing suitable for both wall-mounting and 19“-racks. The coolers can be integrated into the analysis cabinet without empty space requirements at the side for a cooling air outlet.

    The new design enables up to 4 heat exchangers and peristaltic pumps to be incorporated either at the factory or at a later time, without any problem. The exchangers and pumps can be connected in series or parallel following customer requirements.

    An electronic system not only monitors the dew point, but also the ambient temperature. The integrated fan is cooling air temperature dependent controlled.

    A temperature alarm output is wired to the terminal block incorporated of the cooler housing for a safe connection without disassembling the cooler.

    Available for 230VAC and 115VAC power supply.

  • LaserGas II OP

    Open pad gasmonitor over lange afstand
    LaserGas™ II Open Path is a compact, high performance gas monitor for ambient long distance monitoring. The LaserGas™ II OP consists of a transceiver and retro-reflector unit. The retro-reflector unit consists of one or several cube corners in a weather proof enclosure, which reflects the light back to the transceiver. The detector collects the returned light for calculation of the gas concentration. An optional auto-alignment unit can also be applied to ensure consistent alignment over time.
  • LaserGas iQ² Vulcan

    Single-flange O2, CO, CH4, H2O analyser
    LaserGas™ iQ2 Vulcan is the first in-situ single-flange solution to measure up to four gases (O2, CO, CH4, H2O) as well as the process temperature in a single unit. Based on the well-proven and trusted tunable diode laser absorption spectroscopy (TDLAS) technology, the solution combines cutting-edge design and ground-breaking functionality. It is a complete combustion solution eliminating the need for multiple units. Advanced TDLAS technology enables unmatched reliability and durability. Installation costs of this all-in-one solution are significantly reduced since only one flange is needed. In addition, operational and maintenance costs are kept at a minimum.
  • LaserGas III Portable

    Draagbare HF analyser
    LaserGas™ III HF Portable analyzer is compact, lightweight and battery powered instrument which is ideal for HF leakage detection. With on-board pump and connections for Teflon tubing the target gas is continuously transferred into the internal measurement cell. The instrument´s low power design gives long operating time on each battery cycle. The analyzer provides reliable operation with instantaneous response and sufficient dynamic range to measure from sub ppm to several hundred ppm HF concentrations.
  • De Kjeldahl-methode is een methode geschikt om de fractie organische stikstof in samples te bepalen. De methode zal de hoeveelheid stikstof en ammoniak die in organische verbindingen vervat zit analyseren, enkel stikstof in de vorm van nitraten en nitrieten verbindingen worden genegeerd.

    Deze erg oude methode is nog steeds de meest “populaire” (lees erkende) methode voor het bepalen van Stikstof in waters en voedsel samples.

    Omwille van de chemicaliën en de hogere temperaturen die zich in het Kjeldahl proces voordoen is Kjeldahl lang een ongewenste gast op het labo geweest daar de nodige voorzichtigheid aangewezen is.

    Vandaag zijn deze analyses bijna volledig geautomatiseerd, beveiligd en gecontroleerd zodat het gebruik van deze analyzers haast kinderspel geworden is.

  • Litronic FMS II

    Evaluation and transfer module
    A self-sufficient system with almost unlimited possibilities. The Litronic FMS II type moisture measuring installation has been used for decades in a wide range of industries to measure the moisture content of various materials in real time.At the beginning of each measurement section, the calibration per product must be carried out by means of reference procedures. The Litronic-FMS II software enables convenient and fast parameterisation. The evaluation unit receives the raw values measured by the Liebherr sensors and immediately converts them into percentage humidity. Thanks to the various interfaces, transfer to a higher-level control is possible. Measurement by the Liebherr sensor system is based on the physical principle of capacitance determination in the high-frequency stray field. In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility. Once the system has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.
  • Litronic-FMS III / CCS

    Coatingdikte meting
    The Liebherr P78-SC sensor in conjunction with the Liebherr Litronic-FMS/CCS type coating thickness and basis weight determination system has become indispensable for many industrial processes. The areas of use include the coating of paper, box, film, non-woven and textile webs. The sensor installations take place, for example, before and after the squeegee for the exact determination of the coating or the humidity The Litronic-FMS III evaluation and transfer unit, which is a mandatory part of the system, is used to record, process and prepare the values measured by the sensors. The integrated software is used for convenient parametrisation and calibration. Thanks to the various interfaces, signal transmission to the higher-level control is feasible. Measurement by the Liebherr sensor system is based on the physical principle of capacitance determination in the high-frequency stray field. In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility. Once the sensor has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.
  • LaserGas iQ²

    Meet tot 4 gassen O2, CO, CH4, H2O
    LaserGas™ iQ² analyzer is the first to measure up to four gases (O2, CO, CH4, H2O) and temperature depending on configuration, which eliminates the need for multiple units for combustion analysis. The cutting-edge design and ground-breaking functionality, ensures that the instrument delivers unmatched reliability and durability. Customers may replace existing analyzers where explosion risks or high maintenance issues are a huge concern.
  • LaserDust

    Compacte optische in-situ stofmonitors
    LaserDust™ Medium Path (MP), Long Path (LP) en Extra Long Path (XLP) monitoren zijn compacte, optische stofmonitors voor echte continue in-situ meting van stofconcentratie of opaciteit. De monitoren zijn ontworpen voor metingen over pijpen, schoorstenen en kanalen met typische padlengtes van 0,5 – 10 m. LaserDust™-monitoren gebruiken een zender/ontvangerconfiguratie om de stofconcentratie langs de optische zichtlijn te meten. Onze echte contactloze benadering is superieur aan stofmeters van het punttype. Met innovatieve lasertechnologie combineert de LaserDust™ twee meetprincipes in één instrument.
    • Bij lage stofniveaus werkt het met voorwaartse strooilichttechnologie: Het invallende laserlicht wordt verstrooid door stofdeeltjes en verzameld op een solid-state sensor voor stofkwantificering. Deze zeer gevoelige modus maakt detectiegrenzen van < 0,5 mg/Nm3 mogelijk en wordt niet beïnvloed door stofafzetting op de vensters.
    • Bij hoge stofniveaus meet de LaserDust™ de doorlaatbaarheid of opaciteit: Lichtabsorptie door stofdeeltjes wordt opgevangen door een 2e sensor.
  • LaserGas III OP

    Voor continue meting van HF of NH3 in Atex omgeving
    LaserGas™ III Open Path-gasdetector is speciaal ontworpen voor continue bewaking in explosiegevaarlijke omgevingen. Gebaseerd op onze derde generatie LaserGas™-technologie, is het hele instrument ingebouwd in compacte vuurvaste behuizingen, waardoor het ideaal is voor zone 1-locaties. De LaserGas™ III OP bestaat uit een zender- en ontvangereenheid die tegenover elkaar is gemonteerd op een afstand tot 100 meter. Het laserlicht wordt van de zender naar de ontvanger gestuurd en eventuele veranderingen in de gasconcentratie langs het optische pad van de zender naar de ontvanger worden in realtime gedetecteerd.

Titel

Ga naar de bovenkant