• Backwash M1

    Filter Model iFiD
    The heated prefilter model iFiD Filter Backwash M1is a samplegasfilter which can flushbacked with an electronic solenoid valve. This valve can controll the pressure air (flushbackair) and the sample gas. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Heated Prefilter

    Model iFiD Filter XL
    The heated prefilter model iFiD FIlter XL is a samplegasfilter for the high temperature applications with a permanent temperature of 300°C. The filter is very stable with the temperature level you preselect, and also in permanent operation. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of + 1%.
  • The heated prefilter model iFiD Filter is a gasfilter for the high temperature applications who need a permanent temperature up to 300°C. The filter is very stable with the temperature level you can preselected. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of +-1%.
  • The gasstation is fitted with all supplygases who are necessary for a FID measurement. Hydrogen as the fuel gas, nitrogen as zerogas and propane as the calibration gas are available in the one liter bottles who allows a very good handling in mobile measurement. The FID can be connected via teflon hoses and quick connectors.
  • The heated transferline is made of a stainless steal tube with soldered heater. This construction is unique in relation to other lines and is guarantee for a very good heattransfer. Especially in cases of alternating process temperatures, the sample temperature can stabilized at preselected level. A Low-Cost-Version is available with simple teflon hose.
  • The air purifier CAP 15 and air purifier CAP 30 produces clean and hydrocarbon-free air out of normal compressed air. The Pt/Pd-catalyst convert by catalytical total-oxidation at 370°C all hydrocarbons inclusive methane (CH4) into carbondioxyde (CO2) and water (H2O). Hydrogen (H2) and carbonmonoxyde (CO) will be removed quantitatively.The produced air quality ist constantly free of hydrocarbons and better than sythetic air from gas bottles of class 5.0 (refering to organic components).On account of the high gas purity, the air purifier CAP 15/30 are used for FID-measuring systems as combustion air and as zero gas
  • The air purifier CAP 15 and CAP 30 produces clean and hydrocarbon-free air out of normal compressed air. The Pt/Pd-catalyst convert by catalytical total-oxidation at 370°C all hydrocarbons inclusive methane (CH4) into carbondioxyde (CO2) and water (H2O). Hydrogen (H2) and carbonmonoxyde (CO) will be removed quantitatively.The produced air quality ist constantly free of hydrocarbons and better than sythetic air from gas bottles of class 5.0 (refering to organic components).On account of the high gas purity, the air purifier CAP 15/30 are used for FID-measuring systems as combustion air and as zero gas.
  • Litronic FMS IV

    Evaluation and transfer module PROFINET
    A self-sufficient moisture measuring installation with high connectivity and many interesting possibilities. With ProfiNet technology on board, extensive signal processing and WEB-based access, we are ready for Industry 4.0. Without Ethernet support, these tasks cannot be accomplished. At the beginning of each measured section, the calibration per product must be carried out by means of reference procedures. The Litronic-FMS IV software enables convenient and rapid parametrisation. The evaluation unit receives the raw values measured by the Liebherr sensors and immediately converts them into the measured value, such as percentage humidity. Up to 16 sensors can be managed via the WEB with one device. A curve manager and material and sample management helps the user to create the product-specific calibration. Once the system has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age. In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility. A sensor exchange or a transfer to another measured section is also possible without recalibration.
  • Liebherr sensors

    In use in explosion-protected areas
    The self-sufficient measuring device for precise water content/moisture determination in the running process guarantees the highest quality and safety in EX-protected production environments, the further processing and refinement of very many emulsions and bulk materials. The PC software enables fast and accurate calibration of the measured sections.

    Liebherr offers sensors for the following device protection categories:

    Gas EX-protection: II 1/2 G Ex db/ia IIC T4 Ga/Gb* Dust EX-protection: II 1/2 D Ex tb/ia IIIC T135°C Da/Db* *Subject to type approval
    The sensors are installed directly in pipes or in tanks. The sensors are used, for example, in oils, crude oils, paints, lacquers, ethanol, solvents as well as in bulk materials under explosive conditions.
  • The CAN bus is used in on- and off-road applications, vehicles in the construction and agricultural sectors as well as in engines. The CAN bus is integrated in the sensor. The sensor meets critical EMC and environmental requirements. The signals are integrated and processed directly in the customer's control. The CAN bus signals communicate directly with the control apparatus. Measurement by the Liebherr sensor system is based on the physical principle of capacitance determination in the high-frequency stray field. In addition to their high precision and robustness, the sensor system from Bad Schussenried is characterised by its reproducibility. Each CAN sensor is individually calibrated and final tested.
  • Litronic-FMS P30-S

    Planar sensor
    Small, fine, excellent: The Liebherr P30-S sensor in conjunction with the Liebherr FMS moisture measuring installation has become indispensable for many industrial processes. The “Little One” expanded our product portfolio in 2008. Measurement by the Liebherr sensor system is based on the physical principle of capacitance determination in the high-frequency stray field. In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility. Once the sensor has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.
  • For measuring mercury in natural gas the pressure of a high pressure sample feed has to be reduced to a suitable low pressure before measurement. The new NG-SAMPLING SYSTEM-3000 follows a straight forward design. It integrates a minimum of components. All gas wetted parts in the sample path have been silicon coated. This allows very fast conditioning and low memory effects.  
  • LaserGas™ III Ultra

    Voor toepassingen met zeer lange padlengtes en hoge gasconcentraties

    LaserGas™ III Ultra

    It uses the innovative baseline-insensitive TDLAS technique specifically designed for combustion analysis. The Ultra simultaneously meets the requirements of combustion control and safety. That is, high measurement accuracy and high dynamic range with simultaneous real-time measurement capability. Applications with very long path lengths and high gas concentrations are no problem for the Ultra. Thanks to the baseline insensitivity and the use of the proprietary IROSS signal processing, high measurement accuracy is achieved even with complex gas mixtures. LaserGas™ III Ultra CO in combination with LaserGas™ III O2 are a perfect combination for proper combustion control and safety.
  • T-Flens oplossing

    Voor montage van twee LaserGas™ III (Ultra) analysatoren op één enkel paar flenzen
    De T-flensoplossing van NEO Monitors is ontworpen om twee LaserGas™ III (Ultra)-analysatoren op één paar flenzen te plaatsen. Dit maakt metingen met lange optische padlengtes mogelijk, terwijl de benodigde ruimte en installatiekosten worden verminderd. Door het compacte ontwerp zijn de spoelvereisten zeer laag, wat de bedrijfskosten verlaagt. Dankzij een zeer configureerbaar ontwerp kan de T-flensoplossing eenvoudig worden aangepast aan verschillende configuraties en toepassingen; individuele analysers kunnen eenvoudig worden vervangen. De certificeringen van de respectievelijke analysers, b.v. EX-d of SIL2 blijven behouden bij gebruik in de T-flensoplossing. Een typische toepassing is verbrandingsanalyse waarbij de T-Flange in combinatie met een LaserGas™ III O2 en een LaserGas™ III CO Ultra de perfecte oplossing is voor procesoptimalisatie en veiligheid.
  • ZFDM-4 Flue Gas Dust Monitor

    Accurate back scattering

    dust monitor

    Robust and accurate back scattering dust monitor for rough industrial installations

    QAL1 certified continuous monitoring of particulates concentration. Thanks to the backscattering technology, the LED light beam provides an accurate measurement (insensitive to ambient light). The self-checking anti-fouling functions and the continuous automatic correction system correct possible measurement drifts. This device is suitable for small and medium diameter ducts, for very low and medium dust concentrations as well as for light to dark coloured particles.
  • ZPA

    5 components analyser - NDIR single beam

    ZPA is best suited to the measurement of exhaust gas from refuse incinerators, boilers, and various industrial furnaces.

    NO, SO2, CO2, CO, CH4 Non-dispersion infrared-ray absorption methodSingle  light  source  and  single  beams  (single  beam system) O2 : Galvanic fuel cell O2 analyzer (built-in) paramagnetic O2 analyzer (built-in), or zirconia O2 analyzer (externally installed TYPE: ZFK7)

Titel

Ga naar de bovenkant