• Protea 2000

    In-situ Continuous Emissions Monitoring (CEM) IR analysers
    “P2000 is an infra-red (IR), duct or stack-mounted Analyser, designed to provide In-Situ analysis of up to six gas-phase emission components such as CO, CO2, SO2, NO, NO2 and many more. A typical system comprises of a stack mounted Analyser, an integral Calibration Module and a Control Unit with options which include a powerful In-Situ Heater and a stand-alone Analysis Software package.  
  • ProMass Transportable

    Draagbare Quadrupole Mass Spectrometer (QMS) analyser
    For use in the field, ProMass can be provided in a rugged mobile case. With a vacuum start-up in less than 40mins, ProMass can be deployed quickly. Using either the simple PAS-Pro software for unattended operation, or the more complex PAS software for investigation work, ProMass Transportable can give real-time, wide range measurements of any gas.
    • Leak testing (sniffer mode)
    • Syngas analysis
    • Environmental testing
    • Dissolved gas analysis (with membrane inlet)
    • Gas impurity testing
  • Ideally suited to semiconductor production processes, ambient air measurements, leak testing and quality testing for the food industry, the 19” mountable ProMass analyser is a complete process tool. ProMass can be provided with fully integrated vacuum system, or for demanding process applications, an external backing pump is provided – particularly for hazardous area applications. Protea will integrate the ProMass analyser with our sampling control system and industrial analyser controller for a complete measurement system. This can be provided to measure from multiple sample locations is quick succession.
  • ProMass Desktop

    closed ion source and 0-200amu range
    Laboratory QMS Gas Analyser For laboratory applications across many fields of research, the ProMass analyser can be provided in a desktop format. With integrated vacuum system – turbo molecular drag pump and diaphragm roughing pump – ProMass can be operated straight away. A heated capillary of various materials (stainless steel, PEEK, PTFE, borosilicate) is provided included with temperature control of the capillary. Total pressure gauge, analogue and digital inputs, sample pressure and temperature controlled chamber bake-out are all built-in features to give complete sample control.   ProMass uses Protea’s proven RGA quadrupole mass spectrometer that is provided as standard with dual Faraday/SEM detector, closed ion source and 0-200amu range for the analytically focused applications of the ProMass desktop system.
  • Portable Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
  • Portable Multicomponent IR Analyzer

    CO, CO2, CH4, CnHm,O2, H2 + BTU index (gas calorific value)
    The analyzers can measure the concentration of multiple gases simultaneously. It is based on the single source dual-beam non-dispersion infrared (NDIR) method for CO, CO2 , CH4 , CnHm, H2S , SO2 and a micro-TCD (Thermal Conductivity Detector) gas sensor for H2 and O2 by fuel cell method. The analyzers have a digital pulsable infrared source and dual-beam systems
  • This unique microprocessor controlled Peltier Cooler has been designed with a powerful dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1 and 15°C. The condensate that is formed should be removed by a peristaltic pump, automatic drain or collection vessel.

    The heat exchanger is demountable and PFA®-coated.

    The digital controlled cooler has many control and warning features like programmable alarms, mA-output, digital inputs and Modbus or RS485 communication. The alarm status changes when the temperature deviates by • ± 3 °C from the set point.

    Available for 230VAC and 115VAC power supply.

  • Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
  • The APF front panel mounting reliably extra-fine filters solids, in particular very fine particles, from the gas stream for gas conditioning applications. The APF uses a very fine, deep-acting filter element that removes particles larger then 100 nanometer from the gas stream. The large filter surface of the cylindrical filter element guarantees reliable extra-fine filtration and a long service life with low pressure drop.

    The APF extra-fine filter was primarily developed for 19" front-plate mounting equipment, as is evident from the APF’s small size that is suited to flat-design equipment

  • Ankersmid Ambient Air Filters AAF 051 / AAF 052 / AAF 053 are used for the filtration of ambient air in gas monitoring systems.

    The main applications are in ambient air monitoring and in air conditioning systems.

  • nCLD EL²

    NO , NO2 , NOx - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD EL²

    Modular Gas Analyzer The nCLD EL2 analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD EL2 is modular designed and capable of simultaneously measuring NO, NO2 and NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD EL S

    NO / NOx - 5 ppm –5’000 ppm

    ECO PHYSICS nCLD EL S

    Gas Analyzer The nCLD EL S is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL S is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data. connects to other instruments’ data.
  • nCLD EL

    NO / NOx - 0.5 ppm -500 ppm

    ECO PHYSICS nCLD EL

    Gas Analyzer The nCLD EL is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
  • nCLD AL²

    NO, NO2 , NOx - 100 ppb – 50 ppm
    Ambient Level Gas Analyzer The nCLD AL2 is the next generation in two-channel high precision ambient air monitoring instrumentation. Unique in speed and reliability, the nCLD AL2 is modular designed and capable of simultaneously measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD AL

    NO, NO2 , NOx - 100 ppb – 50’000 ppb
    Ambient Level Gas Analyzer  The nCLD AL is the next generation in single-channel high precision ambient air monitoring instrumentation. Unique in speed and reliability, the nCLD AL is modular designed and capable of sequentially measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 899 Y

    NO, NO2 , NOx - 1 ppb – 1’000 ppb
    SupremeLine Trace Gas Analyzer The nCLD 899 Y analyzer is the next generation in ultra high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 899 Y is modular designed and capable of detecting lowest quantities of NO, NO2 and NOX in the range of parts per trillion. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
Ga naar de bovenkant