• Aerosolfilter type AFP

    voor filtreren van vloeibare deeltjes

    The Ankersmid fluid particle filter or coalescence filter is suitable for filtration of fluid particles of all types and is recommended for sample gases with an acid dew point above 100 °C. Application examples are measurements in flue gas of heavy oil and black coal combustions.

    The filter separates the aerosols (very fine fluid particles) which still pass the gas cooler. The most effective position of the filter is downstream the sample conditioning close to the flow meter of the analyser. For additional system protection we provide the version with integrated hydrophobic diaphragm, working as a liquid stop.

  • The Ankersmid wash bottle serves different purposes. First of all, the wash bottle can wash out sample gases. The second application is its role in maintaining a constant pressure upstream of the analyzer by establishing a constant differential pressure with respect to the atmosphere by using the second inlet.
  • The Ankersmid Humidifier controls the humidity of the gas sample stream. The Humidifier is used to wet calibration gases to ensure these gases undergo an identical cycle through the conditioning set-up.

    In this set-up, the calibration gases enter the cooler saturated at a stable dew point. Calibration gases with water-soluble components must not be passed through the humidifier.

  • Adsorptiefilter type AAM

    voor adsorptie van interfererende componenten

    Ankersmid Universal Filters are known as a reliable technique for the adsorption of components in a gas stream that cause interferences in the gas measurement.

    The design of the filter and filter housing ensures that any liquids present in the gas will be separated and collected in the bottom of the filter-housing.

    The AAM series are based on the elements of the AUF universal filter series.

    Due to its universal standard design, the filters can be used with various adsorption cartridges and, if needed, also be fitted with a liquid sensor.

  • Ankersmid Ambient Air Filters AAF 051 / AAF 052 / AAF 053 are used for the filtration of ambient air in gas monitoring systems.

    The main applications are in ambient air monitoring and in air conditioning systems.

  • Draagbare Gasmonstername Probe APP

    met verwarmd filter (180°C)

    Due to various acid dew points at various applications the probe is heated up to 180°C.

    A filter element of 150mm is integrated, suitable for most applications up to 1g dust/m3. A significant advantage is that this filter is replaceable without dismounting the probe. With the filter element of 150mm length this probe is suitable for most applications up to 1g dust/m3; with the blow-back function dust loads of up to 10g/m3 can be handled.

    Calibration gas can be injected directly into the probe through the calibration gas connection according to EN14181 (regulation for calibration of emission monitoring systems) that enables calibration gas feeding via the filter element of the gas sample probe. The use of the optional high-flow check valve type APP 200 is recommended.

    The portable gas sample probe series APP is a perfect completion to the Ankersmid portable gas conditioning system series APS 303/313. Both devices can easily be connected together by the Ankersmid heated sample line type AHL205/025 with the incorporated innovative Quick-Lock System which guarantees a fast and reliable connection.

    Using this heated line the probe's electrical power is then fed to the probe via the feed line integrated within the sample line. To avoid cooling-down and condensation of sample gas in the extraction area, the heated sample probe tube type AST 301 is available.

  • Draagbaar systeem APS

    Draagbaar gasconditioneringssysteem

    The portable system is suitable for variable, discontinuous and continuous operation. The components built into the system can be used for standard applications. For special requirements please ask us for other solutions.

    The heated sample line is to be mounted at the gas measuring inlet terminal inside the portable case. A ball-valve can be fitted to the inlet terminal of the portable system in order to calibrate analyser(s) with check gas.

    The amount of flow is determined by a sample gas diaphragm pump. The sample gas pump AMP 11P is activated automatically by means of an excess temperature contact on the cooler.

    Optional flow meters with integrated needle valve are available. The flow meters are built-in as the electronic controller and are visible from outside when the carrying case is closed. This unique microprocessor controlled Peltier cooler is a powerful designed dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1°C and 15°C. The gas cooler is equipped with an innovative heat exchanger system.

  • Mini Compressorkoeler type ACC

    voor tot maximum 2 gasstromen
    The ACC cooler offers precision, safety and long-term stability for extractive analytics. The very low gas dissolution rate is attained owing to the new cooler technology (Patents applied). Both the permanent separation of the condensate from the gas phase, as well as the shorter contact time of the gas in the system, plays important roles in reducing gas dissolution rates. The new cooler incorporates an advanced structural design with housing suitable for both wall-mounting (standard) and 19“-racks by using optional brackets. The coolers can be integrated into the analysis cabinet without empty space requirements at the side for a cooling air outlet. The design enables 1 or 2 heat exchangers to be incorporated either at the factory or at a later time, without any problem. The exchangers can be connected in series or parallel following customer requirements. An electronic system monitors the dew point and controls the integrated fan. A temperature alarm output is wired to the terminal block incorporated of the cooler housing for a safe connection without disassembling the cooler.

    Available for 230 VAC and 115 VAC power supply.

  • Ankersmid Universal Filters are known as a reliable technique for the separation of particles from gas, ensuring a flow of clean gas to the analyzer. Filter housings in a variety of materials and standard dimensions are available.

    The design of the filter and filter housing also ensures that any liquids present in the gas will be separated from the gas.

    Liquids are collected in the bottom of the filter-housing.

    Due to its universal standard dimensions and functionality, the filter elements can also be used with any commercially available filter housings.

    The filters are easily replaced without the use of any additional tools.

    Where needed, a liquid sensor or liquid drain can be installed at the bottom of the filter housing tube.

  • This unique microprocessor controlled Peltier Cooler has been designed with a powerful dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1 and 15°C. The condensate that is formed should be removed by a peristaltic pump, automatic drain or collection vessel.

    The heat exchanger is demountable and PFA®-coated.

    The digital controlled cooler has many control and warning features like programmable alarms, mA-output, digital inputs and Modbus or RS485 communication. The alarm status changes when the temperature deviates by • ± 3 °C from the set point.

    Available for 230VAC and 115VAC power supply.

  • Gas Sample Probe Series ASP

    Verwarmd, modulaire opbouw met vele opties
    Due to its modular design and various options, the Ankersmid heated sample probe filters cover the widest range of applications. With a choice of different lengths of heated filter body, a filter element of 150mm length, suitable for most applications up to 1g dust/m3 can be integrated. 180mm filters with a larger filter surface are used for applications up to 4g dust/m3; with the blow- back function dust loads of up to 10g/m3 can be handled. The 500mm model filter of the ASP 1500 has a capacity for dust up to 10g/m3. When this type is equipped with blow-back option, it handles up to 20g/m3. For even higher dust loads, a primary filter is positioned on top of the first filter. A significant advantage is that all filters are replaceable without dismounting the probe without using any tools and in the shortest possible time. Cleaning and exchanging of unheated sample tubes or preliminary top-filters can be affected by extracting the filter from the probe. The probe temperature is controlled by a microprocessor based PID-controller (optional with Modbus/RS485 communication). Alarm or fault contacts can be programmed and the temperature can be changed easily. The standard sensor is PT100, whereas a thermo-couple is standard for the high temperature version.
  • Compressorkoeler type ACC

    voor tot 4 maximum gasstromen

    The ACC cooler offers precision, safety and long-term stability for extractive analytics. The very low gas dissolution rate is attained owing to the new cooler technology (Patents applied). Both the permanent separation of the condensate from the gas phase, as well as the shorter contact time of the gas in the system, plays important roles in reducing gas dissolution rates.

    The new cooler incorporates an advanced structural design with housing suitable for both wall-mounting and 19“-racks. The coolers can be integrated into the analysis cabinet without empty space requirements at the side for a cooling air outlet.

    The new design enables up to 4 heat exchangers and peristaltic pumps to be incorporated either at the factory or at a later time, without any problem. The exchangers and pumps can be connected in series or parallel following customer requirements.

    An electronic system not only monitors the dew point, but also the ambient temperature. The integrated fan is cooling air temperature dependent controlled.

    A temperature alarm output is wired to the terminal block incorporated of the cooler housing for a safe connection without disassembling the cooler.

    Available for 230VAC and 115VAC power supply.

  • Spark C2H2

    Sporendetectie voor acetyleen op ppb niveau

    Simple, Drift-Free C2H2 Contaminant Detection

    With the Spark analyzer family, powerful advanced spectroscopy is available at a popular price for a host of applications, from process control and quality assurance in Air Separation Plants to refineries and hydrogen plants. Other applications include monitoring of cylinder filling, bulk delivery and distribution transfer points, as well as welding, medical, industrial and high-purity gas production, and more. Part-per-billion level sensitivity and high-ppm ranges make the Spark an ideal trace gas detection solution for these industrial gas applications. Say goodbye to cumbersome, complex, costly and labor-intensive mid-20th century technology. Gone is the need for calibration, spare parts, limited measurement ranges, and worries about drift and downtime usually associated with NDIRs and GCs. And without the need for H2 fuel gas and with plug-and-play installation within minutes, the Spark is a faster and safer alternative to FIDs. In addition, the Spark has the lowest Cost of Ownership in the industry. The Spark C2H2, along with the Spark CH4, CO and CO2, perfectly complements our popular Spark H2O trace moisture analyzer to utilize powerful, drift-free and hassle-free Cavity Ring-Down Spectroscopy technology for all your critical contaminants.
  • Spark H2O in CO2

    Vochtdetectie in zuivere CO2

    Put a little Spark in your life!

    For the first time, powerful advanced spectroscopy is available at a popular price for a host of applications, from quality assurance to cylinder filling, as well as welding, medical, industrial and high-purity gas production; bulk delivery and distribution transfer points; and more. Say goodbye to cumbersome, complex, costly and labor-intensive mid-20th century technology. Gone is the need for calibration, spare parts, cramped ranges, and worries about drift and downtime. The speed alone will make you gasp. Plus, it's a joy to start-up and to operate.
  • Spark Max CO2

    Sporendetectie voor koolstofdioxide tot < 100 ppb

    Simple, Drift-Free CO2 Contaminant Detection Ideal for Air Separation Plants

    With the Spark Max CO2, the latest generation of Cavity Ring-Down Spectroscopy (CRDS) instrumentation is now available at a popular price for a host of applications, from process control and quality assurance in Air Separation Units to refineries and hydrogen plants. Other applications include monitoring of cylinder filling, bulk delivery and distribution transfer points, fuel-cell hydrogen analysis, as well as welding, medical, industrial and high-purity gas production, and more. Sensitivity below 100 parts per billion and high-ppm ranges make the Spark Max an ideal trace gas detection solution for these industrial gas applications. Say goodbye to cumbersome, complex, costly and labor-intensive mid-20th century technology. Gone is the need for calibration, spare parts, limited measurement ranges, and worries about drift and downtime usually associated with NDIRs and GCs. In addition, the Spark Max has the lowest Cost of Ownership in the industry with fully automatic operation and virtually no maintenance.
  • Spark H2O

    Sporendetectie van vocht tot 3 ppb

    Put a little Spark in your life!

    For the first time, powerful advanced spectroscopy is available at a popular price for a host of applications, from quality assurance to cylinder filling, as well as welding, medical, industrial and high-purity gas production; bulk delivery and distribution transfer points; and more. Say goodbye to cumbersome, complex, costly and labor-intensive mid-20th century technology. Gone is the need for calibration, spare parts, cramped ranges, and worries about drift and downtime. The speed alone will make you gasp. Plus, it's a joy to start-up and to operate.