• Gas Sample Probe Series ASP

    Verwarmd, modulaire opbouw met vele opties
    Due to its modular design and various options, the Ankersmid heated sample probe filters cover the widest range of applications. With a choice of different lengths of heated filter body, a filter element of 150mm length, suitable for most applications up to 1g dust/m3 can be integrated. 180mm filters with a larger filter surface are used for applications up to 4g dust/m3; with the blow- back function dust loads of up to 10g/m3 can be handled. The 500mm model filter of the ASP 1500 has a capacity for dust up to 10g/m3. When this type is equipped with blow-back option, it handles up to 20g/m3. For even higher dust loads, a primary filter is positioned on top of the first filter. A significant advantage is that all filters are replaceable without dismounting the probe without using any tools and in the shortest possible time. Cleaning and exchanging of unheated sample tubes or preliminary top-filters can be affected by extracting the filter from the probe. The probe temperature is controlled by a microprocessor based PID-controller (optional with Modbus/RS485 communication). Alarm or fault contacts can be programmed and the temperature can be changed easily. The standard sensor is PT100, whereas a thermo-couple is standard for the high temperature version.
  • This unique microprocessor controlled Peltier Cooler has been designed with a powerful dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1 and 15°C. The condensate that is formed should be removed by a peristaltic pump, automatic drain or collection vessel.

    The heat exchanger is demountable and PFA®-coated.

    The digital controlled cooler has many control and warning features like programmable alarms, mA-output, digital inputs and Modbus or RS485 communication. The alarm status changes when the temperature deviates by • ± 3 °C from the set point.

    Available for 230VAC and 115VAC power supply.

  • Ankersmid Universal Filters are known as a reliable technique for the separation of particles from gas, ensuring a flow of clean gas to the analyzer. Filter housings in a variety of materials and standard dimensions are available.

    The design of the filter and filter housing also ensures that any liquids present in the gas will be separated from the gas.

    Liquids are collected in the bottom of the filter-housing.

    Due to its universal standard dimensions and functionality, the filter elements can also be used with any commercially available filter housings.

    The filters are easily replaced without the use of any additional tools.

    Where needed, a liquid sensor or liquid drain can be installed at the bottom of the filter housing tube.

  • Mini Compressorkoeler type ACC

    voor tot maximum 2 gasstromen
    The ACC cooler offers precision, safety and long-term stability for extractive analytics. The very low gas dissolution rate is attained owing to the new cooler technology (Patents applied). Both the permanent separation of the condensate from the gas phase, as well as the shorter contact time of the gas in the system, plays important roles in reducing gas dissolution rates. The new cooler incorporates an advanced structural design with housing suitable for both wall-mounting (standard) and 19“-racks by using optional brackets. The coolers can be integrated into the analysis cabinet without empty space requirements at the side for a cooling air outlet. The design enables 1 or 2 heat exchangers to be incorporated either at the factory or at a later time, without any problem. The exchangers can be connected in series or parallel following customer requirements. An electronic system monitors the dew point and controls the integrated fan. A temperature alarm output is wired to the terminal block incorporated of the cooler housing for a safe connection without disassembling the cooler.

    Available for 230 VAC and 115 VAC power supply.

  • Draagbaar systeem APS

    Draagbaar gasconditioneringssysteem

    The portable system is suitable for variable, discontinuous and continuous operation. The components built into the system can be used for standard applications. For special requirements please ask us for other solutions.

    The heated sample line is to be mounted at the gas measuring inlet terminal inside the portable case. A ball-valve can be fitted to the inlet terminal of the portable system in order to calibrate analyser(s) with check gas.

    The amount of flow is determined by a sample gas diaphragm pump. The sample gas pump AMP 11P is activated automatically by means of an excess temperature contact on the cooler.

    Optional flow meters with integrated needle valve are available. The flow meters are built-in as the electronic controller and are visible from outside when the carrying case is closed. This unique microprocessor controlled Peltier cooler is a powerful designed dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1°C and 15°C. The gas cooler is equipped with an innovative heat exchanger system.

  • Draagbare Gasmonstername Probe APP

    met verwarmd filter (180°C)

    Due to various acid dew points at various applications the probe is heated up to 180°C.

    A filter element of 150mm is integrated, suitable for most applications up to 1g dust/m3. A significant advantage is that this filter is replaceable without dismounting the probe. With the filter element of 150mm length this probe is suitable for most applications up to 1g dust/m3; with the blow-back function dust loads of up to 10g/m3 can be handled.

    Calibration gas can be injected directly into the probe through the calibration gas connection according to EN14181 (regulation for calibration of emission monitoring systems) that enables calibration gas feeding via the filter element of the gas sample probe. The use of the optional high-flow check valve type APP 200 is recommended.

    The portable gas sample probe series APP is a perfect completion to the Ankersmid portable gas conditioning system series APS 303/313. Both devices can easily be connected together by the Ankersmid heated sample line type AHL205/025 with the incorporated innovative Quick-Lock System which guarantees a fast and reliable connection.

    Using this heated line the probe's electrical power is then fed to the probe via the feed line integrated within the sample line. To avoid cooling-down and condensation of sample gas in the extraction area, the heated sample probe tube type AST 301 is available.

  • Ankersmid Ambient Air Filters AAF 051 / AAF 052 / AAF 053 are used for the filtration of ambient air in gas monitoring systems.

    The main applications are in ambient air monitoring and in air conditioning systems.

  • Adsorptiefilter type AAM

    voor adsorptie van interfererende componenten

    Ankersmid Universal Filters are known as a reliable technique for the adsorption of components in a gas stream that cause interferences in the gas measurement.

    The design of the filter and filter housing ensures that any liquids present in the gas will be separated and collected in the bottom of the filter-housing.

    The AAM series are based on the elements of the AUF universal filter series.

    Due to its universal standard design, the filters can be used with various adsorption cartridges and, if needed, also be fitted with a liquid sensor.

  • The Ankersmid Humidifier controls the humidity of the gas sample stream. The Humidifier is used to wet calibration gases to ensure these gases undergo an identical cycle through the conditioning set-up.

    In this set-up, the calibration gases enter the cooler saturated at a stable dew point. Calibration gases with water-soluble components must not be passed through the humidifier.

  • The Ankersmid wash bottle serves different purposes. First of all, the wash bottle can wash out sample gases. The second application is its role in maintaining a constant pressure upstream of the analyzer by establishing a constant differential pressure with respect to the atmosphere by using the second inlet.
  • Aerosolfilter type AFP

    voor filtreren van vloeibare deeltjes

    The Ankersmid fluid particle filter or coalescence filter is suitable for filtration of fluid particles of all types and is recommended for sample gases with an acid dew point above 100 °C. Application examples are measurements in flue gas of heavy oil and black coal combustions.

    The filter separates the aerosols (very fine fluid particles) which still pass the gas cooler. The most effective position of the filter is downstream the sample conditioning close to the flow meter of the analyser. For additional system protection we provide the version with integrated hydrophobic diaphragm, working as a liquid stop.

  • The APF front panel mounting reliably extra-fine filters solids, in particular very fine particles, from the gas stream for gas conditioning applications. The APF uses a very fine, deep-acting filter element that removes particles larger then 100 nanometer from the gas stream. The large filter surface of the cylindrical filter element guarantees reliable extra-fine filtration and a long service life with low pressure drop.

    The APF extra-fine filter was primarily developed for 19" front-plate mounting equipment, as is evident from the APF’s small size that is suited to flat-design equipment

  • The ALS liquid-stop protects analyzers against an inrush of liquids from the gas conditioning unit into the analyzer.

    This avoids major damages of the analyser.

    The best position of the liquid is behind the gas conditioning unit, and before the flow meter going to the analyser.

  • YSI 2900 Biochemistry analyzer

    unique fluidics and chamber design resist clogging
    We earned with the biochemistry analyzers a reputation as the Gold Standard in bio-analytical instruments with highly accurate sensors and rapid results. So the key to generating analyte-specific results in 60 seconds or less is YSI’s innovative biosensor technology. Using the inherent specificity of enzymes for a single target analyte, YSI’s proprietary immobilized enzyme electrodes allow a rapid, accurate and largely interference free measurement to be made in about a minute. Most noteworthy is the unique fluidics and chamber design resist clogging – even at high cell densities. Thus as a result combining trusted measurement technology with the latest in automated sample handling, the 2900 serie furthers YSI’s legacy of expertise in the following  applications: • Critical bioprocess monitoring and fermentation control • Biofuel production and research • Clinical blood chemistry • Food and beverage processing
  • VA-100 ViscoScope sensors van Marimex worden ingezet voor standaard toepassingen en zijn verkrijgbaar met NPT en metrische schroefdraad en VARIVENT®- of Tri-clover® fittingen. De toestellen kunnen in kleine tanks, leidingen met kleine diameter of doorstroomcellen worden geïnstalleerd. De sensoren zijn ontworpen voor de lage en gemiddelde viscositeit varieert, procestemperaturen tot 130°C en zijn bijzonder geschikt voor o.a. toepassingen van verven, lakken etc.
  • Automatic sampler robot

    Automatische air-displacement vloeistof sampler

    Het  VERSA 10  werkstation is  een  compacte,  kost effectieve,  high throughput, automatische  air-displacement  vloeistof sampler.

    Het  systeem bied een oplossing voor de nood aan hoge doorvoer vloeistof behandelings mogelijkheden van een klein benchtop model tot een uitgebreid vloer model. Door het combineren van een 4 of 8 kanaals kop maar wel met single kanaals functionaliteit kan dit workstation de routine protocollen automatiseren met een variabele hoeveelheid aan samples. Het compacte 6positie werkplatform zorgt ervoor dat u de pipetteer protocollen kunt uitvoeren in een bio-afzuigkap of plekken met beperkte ruimte.

    Dit systeem ondersteund verschillende eigen reagentia en labware door zijn open systeem en dit aan een zeer aantrekkelijke prijs.

Titel