• iFID Shed

    19" Rack Flame-Ionisation-Detector iFiD SHED for continuous monitoring

    19" Rack Flame-Ionisation-Detector iFiD SHED for continuous monitoring

    The stationary Flame-Ionisation-Detector (FID) iFiD SHED was designed as a 19" Rackunit. This analyzer is designed to measure volatile organic compounds in different sized SHED-chambers. The device is available in a bypass circuit version and an extraction version. The special advantage of the extraction version is a sample flow of only 12-15ml per minute. The whole gaspath is heated to 200°C and with its unique Pyrolysis cleaning system you can clean easily and save service costs.
  • iFiD Rack

    19" rack vlamionisatiedetector voor continue CxHy bewaking

    19" Rack vlamionisatiedetector voor continue CxHy bewaking

    De stationaire vlamionisatiedetector (FID) iFiD Rack is ontworpen voor stack monitoring, proces controle alsook voor VOC meting. Het volledige gaspad is verwarmd op 300°C, vandaar we kunnen spreken van een hoge temperatuur FID.
  • iFiD NMHC Mobile

    The stationary Flame-Ionisation-Detector

    19" RackFlame-Ionisation-Detector iFiD Rack for continuous monitoring

    The stationary Flame-Ionisation-Detector (FID) iFiD RACK is designed for stack monitoring, process control and also for VOC measurement. The whole gaspath is heated to 300°C and so we can speak from a Hightemperature-FID.
  • iFiD NMHC

    The stationary Flame-Ionisation-Detector
    The stationary Flame-Ionisation-Detector (FID) iFiD NMHC measures with its built in NMHC Cutter the methane concentration and parallel in a second channel also the THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability. All components which come in contact with sample are fully heated at 200°.
  • iFID Mobile

    Draagbare Vlamionisatiedetector voor continue CxHybewaking

    Draagbare Vlamionisatiedetector

    De vlamionisatiedetector (FID) meet de totale koolwaterstofconcentratie in industriële en laboratoriumomgevingen. Door zijn lichtgewicht en compacte afmetingen is hij speciaal gemaakt voor dagelijks wisselende meetpunten of kortstondige metingen.
  • iFID Dual

    Continuous monitoring of two parallel channels

    19" RackFlame-Ionisation-Detector iFiD Rack for continuous monitoring of 2 channels parallel

    The stationary Flame-Ionisation-Detector iFiD Dual is designed for measuring at two points with one unit. This saves money in comparison to a 2 unit solution. The channels are separated from each other and so you can permanently measure high and low concentrations paralell without switching procedure.
  • Hydrogen Analysers

    Thermal Conductivity Gas Analyser ZAF and ZAFE
    Reliable process control for furnaces, metal industry, semiconductor and gas separation. The analyser continuously measures the concentration of gases such as H2, He, and Ar with high stability. It is also available in a version for hazardous areas (for countries outside the European Union): ZAFE certified Ex NEPSI.
  • High Pressure STA HP 1/2

    Only available high pressure STA ( High pressure TGA-DSC)

    The LINSEIS High Pressure STA ( High pressure Tg-DSC) delivers unsurpassed performance. The system can be used to determine simultaneous changes of mass (TG) and caloric reactions (HDSC) under defined atmosphere and high pressure (up to 50/150 bar) in the temperature range -170°C up to 1800°C. This instrument is unique because it is the only available high pressure TG-DSC worldwide. The unique characteristics of this product are high precision, high resolution and long term drift stability. The high pressure STA Platinum Series was developed to meet the challenging demands of the high temperature and high pressure applications. Main Application of High Pressure Thermogravimetry-Differential Scanning Calorimetry:
    • Pyrolysis Studies
    • Gasification of Coal and Biomass
    • Testing of Getter Materials (O2, H2, etc.)
    • Metal reduction / oxidation studies
  • The heated transferline is made of a stainless steal tube with soldered heater. This construction is unique in relation to other lines and is guarantee for a very good heattransfer. Especially in cases of alternating process temperatures, the sample temperature can stabilized at preselected level. A Low-Cost-Version is available with simple teflon hose.
  • Heated solenoid valve

    for SHED chamber

    Modell iFiD SHED

    The heated solenoid-valve prevents dilution or increase of the measurement gas concentration by giving up zero gas as well as test gas during or before the shed test measurement.
  • Heated Prefilter

    Model iFiD Filter XL
    The heated prefilter model iFiD FIlter XL is a samplegasfilter for the high temperature applications with a permanent temperature of 300°C. The filter is very stable with the temperature level you preselect, and also in permanent operation. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of + 1%.
  • Heated Inlet Protection Filter model number 1035 is made for filtering the particles from a size of 5μ and bigger out of the samplegas. The Operation time of an Testa-FID without a build in filter (Model 123) can lengthened several times, because this fine filter helps to minimize the change of the sample capillary, the cleaning of the pump and minimize the maintenance. All the spikes you can see without filter are eliminated with our model 1035.
  • GPR-7500

    Kosteneffectieve monitoring van waterstofsulfide niveaus
    De GPR-7500-analyser maakt gebruik van de elektrochemische sensortechnologie met laag vermogen om een ​​kosteneffectieve en gemakkelijk te onderhouden online-installatie waterstofsulfide meting in een klein pakket te bieden.
  • GPR-7100

    Kosteneffectieve monitoring van waterstofsulfide niveaus
    De GPR-7100 is een draagbare H2S-analyser-versie die bij voorkeur wordt gebruikt voor het ter plaatse controleren van het proces of tijdelijk gebruik tijdens onderhoud of inbedrijfstelling van een permanente gasanalysator. Deze geavanceerde instrumenten van AII zijn goedgekeurd voor gebruik in ontvlambare gasstromen.
  • GPR-1000/1100/2000/ 3500 MO

    Voor steekproeven ter plaatse van PPM tot 100% zuurstof
    Deze robuuste draagbare instrumenten zijn geschikt voor sporen zuurstofmetingen van 0,1 ppm tot zuiverheid toepassingen bij 100% zuurstof en delen dezelfde geavanceerde sensortechnologie als de online proces zuurstof analysatoren, waardoor u kunt vertrouwen op hun betrouwbaarheid en nauwkeurigheid. Het concept van Analytical Instruments, waarbij dezelfde HMI en menustructuren worden gebruikt voor draagbare en online analysers, maakt het voor operators uiterst eenvoudig om beide soorten instrumenten op hun locatie te gebruiken zonder dat er extra training nodig is.
  • GPR 1600/2600/3100

    Percent and PPM O2 Monitoring in Bulk Gases
    Ons assortiment zuurstofanalysatoren is ontworpen om gas te bewaken dat wordt geproduceerd of gebruikt in industriële processen waar zuurstofspoor van lage deeltjes per miljoen tot pure O2 nauwkeurig moet worden gemeten. Door gebruik te maken van de hoogwaardige galvanische zuurstofsensoren van AII zijn deze geavanceerde instrumenten eenvoudig te gebruiken met een gemeenschappelijke HMI en menustructuur voor het hele bereik. Operators hoeven slechts één instrument te leren voor meerdere gasanalysetoepassingen bij verschillende zuurstofniveaus. Verkrijgbaar als bench-, 19 "rack-, panel- en wandmontage voor flexibele installatie.
  • GMD 13

    Gravimetrisch meetsysteem
    • patented world innovation: Sampling and weighting in one system on site!
    • intelligent system for isokinetic dust and fine particles measurements in exhaust air ducts and stacks
    • acquisition of all necessary gas boundary parameters (humidity of the sample gas, velocity in exhaust gas channel, temperature, pressure)
    • pivotable graphic display for more convenient operations
  • GMD 12

    Gravimetrisch meetsysteem
    • intelligent system for isokinetic dust and fine particles measurements in exhaust air ducts and stacks
    • acquisition of all necessary gas boundary parameters (humidity of the sample gas, velocity in exhaust gas channel, temperature, pressure)
    • pivotable graphic display for more convenient operations
  • The Ankersmid Humidifier controls the humidity of the gas sample stream. The Humidifier is used to wet calibration gases to ensure these gases undergo an identical cycle through the conditioning set-up.

    In this set-up, the calibration gases enter the cooler saturated at a stable dew point. Calibration gases with water-soluble components must not be passed through the humidifier.

  • Gas Sample Probe Series ASP

    Verwarmd, modulaire opbouw met vele opties
    Due to its modular design and various options, the Ankersmid heated sample probe filters cover the widest range of applications. With a choice of different lengths of heated filter body, a filter element of 150mm length, suitable for most applications up to 1g dust/m3 can be integrated. 180mm filters with a larger filter surface are used for applications up to 4g dust/m3; with the blow- back function dust loads of up to 10g/m3 can be handled. The 500mm model filter of the ASP 1500 has a capacity for dust up to 10g/m3. When this type is equipped with blow-back option, it handles up to 20g/m3. For even higher dust loads, a primary filter is positioned on top of the first filter. A significant advantage is that all filters are replaceable without dismounting the probe without using any tools and in the shortest possible time. Cleaning and exchanging of unheated sample tubes or preliminary top-filters can be affected by extracting the filter from the probe. The probe temperature is controlled by a microprocessor based PID-controller (optional with Modbus/RS485 communication). Alarm or fault contacts can be programmed and the temperature can be changed easily. The standard sensor is PT100, whereas a thermo-couple is standard for the high temperature version.
  • Flue Gas Humidity Monitors Delta-O2

    In-situ or extractive O2 + H2O monitors
    Continuous measurement of humidity in highly dusts loaded flue gas through dry and wet zirconia oxygen measurements. In-situ or extractive O2 + H2O monitors depending on the application. Perfect for combustion control of biomass boilers : industrial boilers, district heating.
    O2 DRY  -  O2 WET -  H2O
  • Microventuri based continuous monitoring of flue gas flow rate, pressure and temperature
    Designed for tough industrial applications with highly dusts loaded fl ue gas.
  • FL007

    Olie in water analyser
    The Kemtrak FL007 is a fiber optic probe based oil in water monitor. A state-of-the-art combined fluorescence and turbidity measurement assures reliable continuous monitoring of oil and hydrocarbon contamination in water. Mineral oils rich in aromatic content will fluoresce when illuminated with ultraviolet light. The intensity of this fluorescence is dependent upon the polyaromatic hydrocarbon (PAH) content of the oil. Typical oils that fluoresce include fuel oil, crude oil, hydraulic oil and transformer oil.
  • The filterinlet model iFiD Filter is a flashbackable filterunit for all heated Testa Samplegasfilters. The filter is usable for exhaust gas from engines as well as for emmission measuring tasks.
  • The heated prefilter model iFiD Filter is a gasfilter for the high temperature applications who need a permanent temperature up to 300°C. The filter is very stable with the temperature level you can preselected. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of +-1%.
  • FID 3001W

    Analytical section heated on 300°C

    Wall mount Flame-Ionisation-Detector 3001W

    The Flame-Ionisation-Detector 3001W measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. Because of its swingable housing, there is an easy installation and optimal accessibility guaranteed. This wallmounted analyser is a compact, robust weatherproofed version. The environmental protectionmode is IP65.
  • FID 2010 T

    Draagbare Vlam-Ionisatie-Detector FID 2010T voor continue monitoring van CxHy - Classic Line

    Total Hydrocarbon Analyser

    The Flame-Ionisation-Detector 2010 T measures Total HydroCarbon (THC) in a wide range of applications like catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases.By it`s little weight and it`s compact dimensions, he is especially made for daily changing measuring points or shorttime measurings campains.
  • FID 2010 NMHC

    Draagbare Methaan/CxHy Analyser

    Methaan/THC Analysator

    De draagbare verwarmde FID 2010 NMHC van TESTA meet met zijn ingebouwde NMHC-cutter de methaanconcentratie (alleen methaan) en na overschakeling op een ander kanaal ook de THC in een breed scala aan toepassingen zoals bewaking van schoorsteengasemissies, bewaking van omgevingslucht, monitoring van thermische reactor- en verbrandingsemissies en ook uitlaatgassen van voertuigen. De monitoring is continu met een hoge nauwkeurigheid, gevoeligheid en stabiliteit. Alle componenten die in contact komen met het monster worden volledig verwarmd op 200°.
  • FID 2000MP SHED

    Connection for 4 calibration gases

    Mini/Micro-SHED

    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in SHED-chambers of different sizes. For applications beginning of 2,5m3 we recommend to measure in a heated circular system to get a response time near to real changes of concentration in the chamber. For smaller chambers, we have developed a special FID-analyzer with a sample flow of 12ml/min. These two types of analyzers optimizethe air change rateover the extraction rate.
  • FID 2000 MP

    Analytical section heated on 200°C
    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in a wide range of applications like all kind of emission control, catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air (immissions), solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy.
  • FID 1230 NMHC

    Methane only / CxHy monitoring system (Change-over switch)
    Methane only / Total Hydrocarbon THC monitoring system (Change-over switch) The 19” Flame-Ionisation-Detector (FID) 1230NMHC measures with its built-in NMHC-Cutter the methane concentration (methane only) and after switching to THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability.
  • FID 1230 Module

    Vlam-Ionisatie-Detector 1230 Module voor continue monitoring van CxHy

    19" rack version Flame-Ionisation Detector FID 1230

    The Flame-Ionisation-Detector FID1230 Module measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy. Because of the module system, there is an optimal configuration for every measurement-task under profit aspects possible. All modules can be fit in at any time.