• FID 2000MP SHED

    Connection for 4 calibration gases

    Mini/Micro-SHED

    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in SHED-chambers of different sizes. For applications beginning of 2,5m3 we recommend to measure in a heated circular system to get a response time near to real changes of concentration in the chamber. For smaller chambers, we have developed a special FID-analyzer with a sample flow of 12ml/min. These two types of analyzers optimizethe air change rateover the extraction rate.
  • FID 2000 MP

    Analytical section heated on 200°C
    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in a wide range of applications like all kind of emission control, catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air (immissions), solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy.
  • FID 1230 NMHC

    Methane only / CxHy monitoring system (Change-over switch)
    Methane only / Total Hydrocarbon THC monitoring system (Change-over switch) The 19” Flame-Ionisation-Detector (FID) 1230NMHC measures with its built-in NMHC-Cutter the methane concentration (methane only) and after switching to THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability.
  • FID 2010 NMHC

    Draagbare Methaan/CxHy Analyser

    Methaan/THC Analysator

    De draagbare verwarmde FID 2010 NMHC van TESTA meet met zijn ingebouwde NMHC-cutter de methaanconcentratie (alleen methaan) en na overschakeling op een ander kanaal ook de THC in een breed scala aan toepassingen zoals bewaking van schoorsteengasemissies, bewaking van omgevingslucht, monitoring van thermische reactor- en verbrandingsemissies en ook uitlaatgassen van voertuigen. De monitoring is continu met een hoge nauwkeurigheid, gevoeligheid en stabiliteit. Alle componenten die in contact komen met het monster worden volledig verwarmd op 200°.
  • FID 3001W

    Analytical section heated on 300°C

    Wall mount Flame-Ionisation-Detector 3001W

    The Flame-Ionisation-Detector 3001W measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. Because of its swingable housing, there is an easy installation and optimal accessibility guaranteed. This wallmounted analyser is a compact, robust weatherproofed version. The environmental protectionmode is IP65.
  • FID 1230 IH

    The flame-ionization-detector 1230 IH for continuous high temperature (400°C) monitoring of THC

    High-Temperature Analyzer for Exhaust gas measurement

    The flame-ionization-detector 1230I-H can measure the sum of total hydrocarbon concentrationin applications like cold starts of engines (down to–40°Cambient temperature), inwoodburning systems and also at engine test units (especially oil-and gasburners, airplaneengines etc.) Our high temperature heated lines with a operation temperature of 400°C are made additionally for measurements of highboiling hydrocarbons. For the sample-gas pickup we have built some prefilters who are able to hold back the tar compounds.
  • FID 1230 Module

    Vlam-Ionisatie-Detector 1230 Module voor continue monitoring van CxHy

    19" rack version Flame-Ionisation Detector FID 1230

    The Flame-Ionisation-Detector FID1230 Module measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy. Because of the module system, there is an optimal configuration for every measurement-task under profit aspects possible. All modules can be fit in at any time.
  • FID 2010 T

    Draagbare Vlam-Ionisatie-Detector FID 2010T voor continue monitoring van CxHy - Classic Line

    Total Hydrocarbon Analyser

    The Flame-Ionisation-Detector 2010 T measures Total HydroCarbon (THC) in a wide range of applications like catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases.By it`s little weight and it`s compact dimensions, he is especially made for daily changing measuring points or shorttime measurings campains.
  • ProtIR 204M

    Transporteerbare CEM gebaseerd op FTIR technologie
    The 204M is a transportable CEM based on FTIR technology. Using the 204M for measurements of waste incineration and combustion plant process is as simple using an FTIR can be. With pre-loaded calibration methods for 28 gas species, automatic nitrogen purging, in-built pressure and temperature alarms, analogue and digital I/O it is a complete site-ready back up CEM. The ProtIR 204M and PAS software have been designed to allow stack emission monitoring to be carried out to the Environment Agency’s Technical Guidance Note M22 Measuring stack gas emissions using FTIR instruments (TGN M22) as simply and quickly as possible. With the built-in Standard Analysis Model for common gases there is no complex set-up of analysis required. The software as built-in calculations for drift and residual analysis, following the methods described in TGN M22. Skilled users of the FTIR can use the chemometric building routines of the PAS software to build analytical methods for specific applications. Set up this way, the 204M can measure thousands of possible gas species over ranges from ppm to %Vol.
  • atmosFIRt

    Draagbare multigas FTIR gasanalyser voor emissiemeting
    atmosFIRt is the latest generation of FTIR gas analyser technology from Protea in a portable or mobile form. The atmosFIR system improves upon previous FTIR technology and represents one of the most cost-effective and flexible analytical products on the market today. At the heart of atmosFIR is a high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIR has been developed to incorporate the latest improvements and advantages in technology.
  • atmosFIRw

    Wall-mounted multigas analyser for ambient air and process monitoring
    atmosFIR is the latest generation of gas analyser technology from Protea. The atmosFIR system improves upon previous FTIR technology and represents one of the most cost-effective and flexible analytical products on the market today. atmosFIRw has been designed to give a complete measurement system with embedded touchscreen controller. At the heart of atmosFIRw is a high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIRw has been developed to incorporate the latest improvements and advantages in technology, including:
    • Low cost of ownership and maintenance
    • Robust and light, including the latest in fabrication materials
    • atmosFIR combines an FTIR analyser with an in-built sampling system and embedded PC controller for a complete system
  • atmosFIR

    Multi-component FTIR gas analyser, measuring sub-ppm to low %Vol online
    atmosFIR is the successor to Protea's previous emissions monitoring FTIR systems, keeping all the features that users found valuable in achieving their measurement results, but offering the benefits of the new atmosFIR platform with increased portability, lower ownership costs and increased measurement performance. atmosFIR can be considered a simple multi-gas analyser for combustion gas measurements; indeed for some users that is all it will be and as such it provides a cost-effective and complete measurement system. However, for the expert user atmosFIR will offer all the benefits of FTIR, with hundreds of gas measurements, multiple analytical ranges, in-depth chemometric result diagnoses and dedicated on-board sampling system. With Protea's in-house chemometrics application support and 15+ year history of emission monitoring projects, atmosFIR offers the user the complete package for their monitoring needs. With long-lifetime VCSEL reference laser diode, unique cell design, and air cooled DTGS detector with 24-bit ADC, atmosFIR is a step-change in value and service lifetime for FTIR emission gas analysis.
  • atmosFIR CEM

    Continuous Emissions Monitoring FTIR
    atmosFIR CEM is a complete emissions monitoring system incorporating the atmosFIR 19” FTIR analyser. As completely hot and wet emissions measurement, atmosFIR CEM is ideal for complete measurement of multiple gases from applications such as incineration and power. A standard gas suite of NO, NO2, N2O, SO2, NH3, HCl, CH4, O2, CO2 and H2O is provided, but with the powerful FTIR analyser, further gases can be added easily in software. At the heart of system is the high-resolution, robust and proven FTIR spectrometer offering high signal throughput, low-noise and long lifetime of components. atmosFIR has been developed to incorporate the latest improvements and advantages in technology, The atmosFIR FTIR analyser contains an in-built sampling system and is designed for ppm-level emissions monitoring. The analyser can be used as a portable or bench-top unit as well as part of the installed CEM system.
  • Backscatter probes

    0.0005% (10 NTU) to 100% solids
    Kemtrak backscatter probes are designed to accurately measure low to extremely high turbidity directly in tanks and pipelines. The dual fiber optic design of the Kemtrak probe provides high resolution at low turbidity ranges with excellent linearity all the way up to extremely high turbidities when used with a Kemtrak NBP007 backscatter photometer. A unique benefit of the Kemtrak backscatter immersion probe is that it does not go blind at high sample turbidities. Other probes stop working at 4 000 NTU/FNU (< 1 wt% solids) after which the signal will decrease resulting in an erroneous and misleading output. The output of the Kemtrak probe will continue to increase with sample concentration ensuring a reliable measurement.  
  • Measurement cells

    Pressure from 10 mbar to 200 bar (0,14 – 2900 psi)

    In-line Fiber Optic Measurement cells

    Kemtrak industrial process measurement cells are manufactured from the highest quality materials and are designed to the most demanding specifications to ensure long life and the highest reliability. Industrial grade fiber optics transmit cold light to the measurement cell and back. The measurement cell contains no electronics, moving parts or sources of heat that would result in condensation on the optical surfaces and they are well suited for hazardous area operation.
  • Ultratracer UT-3000

    Analyser voor totaal kwikgas in lucht en andere gassen op ultra-laag niveau

    Measuring of Total Gaseous Mercury (TGM) in air and other gases at ultra trace levels

    The UT-3000 Mercury Ultratracer provides a compact and reliable tool for measuring mercury in gases at ultra trace levels. Utilizing the high performance GoldTrap amalgamation module and an optimized state-of-the-art AA-mercury vapor detector the UT-3000 Ultratracer offers detection limits at sub-ng/m³ (ppq-parts per quadrillion) levels.  
  • Tracker-3000 XS

    Draagbare kwikanalyser

    The new Mercury Tracker-3000 XS

    - lighter - smaller - more comfortable We updated the well-proven Mercury Tracker 3000 IP! The new Mercury Tracker-3000 XS weighs even less, it is smaller, easier to handle and features GPS, a 5.7" color TFT display and new high performance Eneloop battery pack with minimized self-discharge. Needless to say the benefits of the old Tracker were not discarded.
    • Real time measurement
    • High precision measuring principle: atomic absorption (AAS)
    • Easy to operate
    • Shock proof and corrosion resistant for rugged field operation
    • Measuring ranges 0.1-100 / 0-1000 / 0-2000 µg/m³
    • High resolution 0.0001 mg/m³
    • Data logger integrated
  • VM-3000

    Detectie van kwik in lucht en andere gassen
    The VM-3000 Mercury Vapor Monitor measures the mercury concentration in gases continuously. It is used in the laboratory or can be installed at places where mercury has to be monitored. It is a great tool for plenty of different fields of applications in scientific research or the industrial sector:
    • Work place monitoring
    • Research and science
    • Emissions monitoring
    • Quality control of industrial gas
    • Investigation of contaminated sites
    • Environmental monitoring
    • Hazardous waste inspection
  • ASP 320 DeNox

    DeNOx-processen (SCR)
    The probe type ASP 320 is based on the standard Ankersmid sample probe. Due to its modular and innovative design the Ankersmid heated sample probe cover also meet the special requirements of above mentioned application. With the heated filter body a filter element of 150mm length, suitable for most applications up to 1g dust/m3, is integrated. When the integrated port is used for back-flush higher dust loads can be handled. Additional a pre-filter can be mounted on top of the sample probe. The filter element can be replaced without any tools and in the shortest possible time. At the sample gas outlet of the probe a special non-heated condensate vessel of glass is mounted. It is filled with glass balls to extend the surface for the salification. The salt deposits and will be washed out with the condensate. A peristaltic pump type ASR25 continuously removes the condensate with the solved ammonium salts. The temperature of the vessel is higher than the ambient temperature because of the hot gas stream. Therefore a loss of measured components is negligible because of warm condensate. In case of a DeNOx application with a small content of NH3 (normally only a few ppm) it is possible to analyse SO2 and NOX without great losses (only some ppm which normally can be neglected). To determine the loss, it is possible to give test gas via the probe to the analyser(s). A measuring fault can be found and calibrated. As an option the vessel can be heated as well to suppress chemical reactions of the measured component below a defined temperature. At the sample outlet of the vessel a heated gas sample line series AHL can be connected.
  • Protea 5000

    In-situ Continuous Emissions Monitoring (CEM) UV analysers
    Protea 5000 is an ultra-violet (UV), continuous emission monitoring analyser, designed for in-situ analysis of gas-phase emission components. Using absorption spectroscopy, Protea 5000 stores and analyses the full UV spectrum and calculates the gas emission concentrations for e.g. NH3, Cl2, HCl, SO2, F2 and many more.
  • Protea 2000

    In-situ Continuous Emissions Monitoring (CEM) IR analysers
    “P2000 is an infra-red (IR), duct or stack-mounted Analyser, designed to provide In-Situ analysis of up to six gas-phase emission components such as CO, CO2, SO2, NO, NO2 and many more. A typical system comprises of a stack mounted Analyser, an integral Calibration Module and a Control Unit with options which include a powerful In-Situ Heater and a stand-alone Analysis Software package.  
  • nCLD AL²

    NO, NO2 , NOx - 100 ppb – 50 ppm
    Ambient Level Gas Analyzer The nCLD AL2 is the next generation in two-channel high precision ambient air monitoring instrumentation. Unique in speed and reliability, the nCLD AL2 is modular designed and capable of simultaneously measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD AL

    NO, NO2 , NOx - 100 ppb – 50’000 ppb
    Ambient Level Gas Analyzer  The nCLD AL is the next generation in single-channel high precision ambient air monitoring instrumentation. Unique in speed and reliability, the nCLD AL is modular designed and capable of sequentially measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.
  • CraNOx II

    NO, NO₂, NOₓ, O₃ - 1 ppb – 1’000 ppb
    SupremeLine Trace Gas Analyzer With CraNOx II, ECO PHYSICS is launching the second generation of its high-end measurement solution in the ppb and ppt range. The new system is smaller and more sophisticated, as it now has the power to calculate the photostatic equilibrium by means of the integrated ozone analyzer. The CraNOx II system is capable of simultaneously measuring NO, NOX, NO2 and O3. Furthermore, it can be expanded to assess NOY and NH3 concentrations.
  • nCLD 811 CM

    NO, NO2, NOx, NH3, NOx – Amines - 1 ppm -10’000 ppm
    SupremeLine Gas Analyzer The nCLD 811 CM is the next generation in two-channel emissions monitoring instrumentation. Unique in speed and reliability, the nCLD 811 CM is modular designed and allows the continuous analysis of NO, NO2, NOX, NH3 and NOX-Amines in raw exhaust gasses and other samples with NOX concentrations ranging from several thousand ppm down to a ppb. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 899 Y

    NO, NO2 , NOx - 1 ppb – 1’000 ppb
    SupremeLine Trace Gas Analyzer The nCLD 899 Y analyzer is the next generation in ultra high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 899 Y is modular designed and capable of detecting lowest quantities of NO, NO2 and NOX in the range of parts per trillion. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • LaserGas III SP

    Cross stack meting voor Atex Zone I, optie SIL2
    LaserGas™ III SP is the third generation in-situ analyzer, designed for safety applications with a special focus on SIL-applications and Ex-d. A compact sized instrument which is easy to install. The instrument is a placed in a sealed housing which eliminates the need for instrument purging.The instrument does not require regular maintenance. The monitor is mounted directly onto flanges, which include purge gas connections and a tilting mechanism for easy alignment. Continuous purge flow prevents dust and other contamination from settling on the optical windows. Once power and data lines are connected, measurements are performed in real-time.
  • nCLD 811 M

    NO, NO2 , NOx - 1 ppm - 10’000 ppm

    ECO PHYSICS nCLD 811 M

    SupremeLine Gas Analyzer The nCLD 811 M is the next generation in two-channel emissions monitoring instrumentation. Unique in speed and reliability, the nCLD 811 M is modular designed and allows the continuous and simultaneous analysis of NO, NO2 and NOX in raw exhaust gasses with NOX concentrations ranging from several thousand ppm down to a ppb. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 88 Yp

    NO / NOx - 5 ppb – 5’000 ppb

    ECO PHYSICS nCLD 88 Yp

    Modular Trace-Level Gas Analyzer The nCLD 88 Yp is the next generation in measuring smallest amounts of NO or NOX. Unique in speed and precision, the nCLD 88 Yp is modular designed and allows the sequential measurement of concentrations even in the range of parts per trillion and is expandable to assess additional nitrogen oxide based parameters. Its new and intuitive user interface also individually displays and connects to other instruments’ data.
  • nCLD 855 Y

    NO, NO2 , NOx - 100 ppb – 50’000 ppb

    ECO PHYSICS nCLD 855 Y

    Modular Gas Analyzer The nCLD 855 Y analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 855 Y is modular designed and capable of simultaneously measuring NO, NO2 and NOX. The analyzer’s expandable capabilities allow assessment of hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 844 CMhr

    NO, NO2, NOx, NH3, NOx–amines - 0.5 ppm – 500 ppm

    ECO PHYSICS nCLD 844 CMhr

    Modular Gas Analyzer The nCLD 844 CMhr analyzer is the next generation in high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 CMhr is modular designed and capable of sequentially measuring NO, NO2, NOX, NH3 and NOX-Amines. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 844 Mhr

    NO, NO2 , NOx - 0.5 ppm – 500 ppm

    ECO PHYSICS nCLD 844 Mhr

    Modular Gas Analyzer The nCLD 844 Mhr analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 Mhr is modular designed and capable of simultaneously measuring NO, NO2 and NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 844 Mh

    NO, NO2 , NOx - 0.5 ppm – 500 ppm
    Modular Gas Analyzer The nCLD 844 Mh analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 Mh is modular designed and capable of simultaneously measuring NO, NO2 and NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 844 M

    NO, NO2 , NOx - 0.5 ppm – 500 ppm

    ECO PHYSICS nCLD 844 M

    Modular Gas Analyzer The nCLD 844 M analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 M is modular designed and capable of simultaneously measuring NO, NO2 and NOX. The analyzer’s expandable capabilities allow assessment of hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 822 SSdhr

    NOx - NOx dual-channel - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 822 SSdhr

    Modular Gas Analyzer The nCLD 822 SSdhr analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 SSdhr is modular designed and capable of directly and simultaneously measuring NOX in rough samples from two hot and moist sources without additional gas preconditioning unit. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 822 CMhr

    NO, NO2 , NOx , NH3 , NOx – Amines - 5–5’000 ppm

    ECO PHYSICS nCLD 822 CMhr

    Modular Gas Analyzer The nCLD 822 CMhr analyzer is the next generation in high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 CMhr is modular designed and capable of sequentially measuring NO, NO2 , NOX , NH3 and NOX-Amines from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 822 Mr

    NO , NO2 , NOx - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 822 Mr

    Modular Gas Analyzer The nCLD 822 Mr analyzer is the next generation in high precision two-channel nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 Mr is modular designed and capable of simultaneously measuring NO, NO2 and NOX from sources with pressure variations. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD EL²

    NO , NO2 , NOx - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD EL²

    Modular Gas Analyzer The nCLD EL2 analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD EL2 is modular designed and capable of simultaneously measuring NO, NO2 and NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 822 M

    NO , NO2 , NOx- 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 822 M

    Modular Gas Analyzer The nCLD 822 M analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 M is modular designed and capable of simultaneously measuring NO, NO2 and NOX. The analyzer’s expandable capabilities allow assessment of hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 84 M

    NO / NOx - 0.5 ppm –500 ppm

    ECO PHYSICS nCLD 84 M

    Modular Gas Analyzer The nCLD 84 M analyzer is the next generation in single-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 84 M is modular designed and capable of measuring NO or NOX. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 82 Mh

    NO / NOx - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 82 Mh

    Modular Gas Analyzer The nCLD 82 Mh analyzer is the next generation in high precision single-channel nitrogen oxide measurement. Unique in speed and reliability, the nCLD 82 Mh is modular designed and capable of measuring NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 82 S

    NO / NOx - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 82 S

    Modular Gas Analyzer The nCLD 82 S analyzer is the next generation in single-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 82 M is modular designed and capable of measuring NO or NOX . The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 63 MOx

    NO / NOx O2, CO2 - 0.5 ppm – 500 ppm

    ECO PHYSICS nCLD 63 MOx

    Multi-Gas Analyzer The nCLD 63 MOx is the next generation in measuring NO/NOx , O2 and CO2. Unique in speed and precision, the nCLD 63 MOx is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principles comply with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
  • nCLD 62 MOx

    NO / NOx O2, CO2 - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 62 MOx

    Multi-Gas Analyzer The nCLD 62 MOx is the next generation in measuring NO/NOX , O2 and CO2. Unique in speed and precision, the nCLD 62 MOx is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principles comply with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
  • nCLD EL

    NO / NOx - 0.5 ppm -500 ppm

    ECO PHYSICS nCLD EL

    Gas Analyzer The nCLD EL is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
  • nCLD 66 Y

    NO / NOx - 50 ppb – 25’000 ppb

    ECO PHYSICS nCLD 66 Y

    Gas Analyzer The nCLD 66 Y is the next generation in single-channel ambient air monitoring instrumentation. Unique in speed and precision, the nCLD 66 Y is modular designed and capable of sequentially measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen oxide based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD EL S

    NO / NOx - 5 ppm –5’000 ppm

    ECO PHYSICS nCLD EL S

    Gas Analyzer The nCLD EL S is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL S is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data. connects to other instruments’ data.
  • iFID Dual

    Continuous monitoring of two parallel channels

    19" RackFlame-Ionisation-Detector iFiD Rack for continuous monitoring of 2 channels parallel

    The stationary Flame-Ionisation-Detector iFiD Dual is designed for measuring at two points with one unit. This saves money in comparison to a 2 unit solution. The channels are separated from each other and so you can permanently measure high and low concentrations paralell without switching procedure.

Titel

Ga naar de bovenkant