• The heated sampling system is a combination of a heated sample line and a heated sample filter. The sample line is 500mm long; the filter element can be replaced very quick with the bayonet lock. Beside the very precisious and constant regulation of the line and filter temperature, there is a separate controll point fort he temperature at the filterinlet, where you have an information of the exhaust gas temperature. Also the calibration gas (prewarmed) can directly connected with the unit. The thermocouple is available as PT 100 or NiCrNi.
  • Heated solenoid valve

    for SHED chamber

    Modell iFiD SHED

    The heated solenoid-valve prevents dilution or increase of the measurement gas concentration by giving up zero gas as well as test gas during or before the shed test measurement.
  • The heated 3-way solenoid valve is made for switching 2 heated lines on one analyzer. Beside this there is a second outlet for IR-analyzers or other analyzers built in.
  • The filterinlet model iFiD Filter is a flashbackable filterunit for all heated Testa Samplegasfilters. The filter is usable for exhaust gas from engines as well as for emmission measuring tasks.
  • Backwash M2

    Filter iFiD
    The heated prefilter model iFiD Backwash M2 is a samplegasfilter which can be flushbacked. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Backwash M1

    Filter Model iFiD
    The heated prefilter model iFiD Filter Backwash M1is a samplegasfilter which can flushbacked with an electronic solenoid valve. This valve can controll the pressure air (flushbackair) and the sample gas. The filter is very stable with the temperature level you preselect, and also in permanent use. In permanent use the maximum temperature is 200°C. The temperature is regulated in a range of +-1%.
  • Heated Prefilter

    Model iFiD Filter XL
    The heated prefilter model iFiD FIlter XL is a samplegasfilter for the high temperature applications with a permanent temperature of 300°C. The filter is very stable with the temperature level you preselect, and also in permanent operation. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of + 1%.
  • The heated prefilter model iFiD Filter is a gasfilter for the high temperature applications who need a permanent temperature up to 300°C. The filter is very stable with the temperature level you can preselected. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of +-1%.
  • The gasstation is fitted with all supplygases who are necessary for a FID measurement. Hydrogen as the fuel gas, nitrogen as zerogas and propane as the calibration gas are available in the one liter bottles who allows a very good handling in mobile measurement. The FID can be connected via teflon hoses and quick connectors.
  • The heated transferline is made of a stainless steal tube with soldered heater. This construction is unique in relation to other lines and is guarantee for a very good heattransfer. Especially in cases of alternating process temperatures, the sample temperature can stabilized at preselected level. A Low-Cost-Version is available with simple teflon hose.
  • The air purifier CAP 15 and air purifier CAP 30 produces clean and hydrocarbon-free air out of normal compressed air. The Pt/Pd-catalyst convert by catalytical total-oxidation at 370°C all hydrocarbons inclusive methane (CH4) into carbondioxyde (CO2) and water (H2O). Hydrogen (H2) and carbonmonoxyde (CO) will be removed quantitatively.The produced air quality ist constantly free of hydrocarbons and better than sythetic air from gas bottles of class 5.0 (refering to organic components).On account of the high gas purity, the air purifier CAP 15/30 are used for FID-measuring systems as combustion air and as zero gas
  • LaserGas™ III Ultra

    Voor toepassingen met zeer lange padlengtes en hoge gasconcentraties

    LaserGas™ III Ultra

    It uses the innovative baseline-insensitive TDLAS technique specifically designed for combustion analysis. The Ultra simultaneously meets the requirements of combustion control and safety. That is, high measurement accuracy and high dynamic range with simultaneous real-time measurement capability. Applications with very long path lengths and high gas concentrations are no problem for the Ultra. Thanks to the baseline insensitivity and the use of the proprietary IROSS signal processing, high measurement accuracy is achieved even with complex gas mixtures. LaserGas™ III Ultra CO in combination with LaserGas™ III O2 are a perfect combination for proper combustion control and safety.
  • T-Flens oplossing

    Voor montage van twee LaserGas™ III (Ultra) analysatoren op één enkel paar flenzen
    De T-flensoplossing van NEO Monitors is ontworpen om twee LaserGas™ III (Ultra)-analysatoren op één paar flenzen te plaatsen. Dit maakt metingen met lange optische padlengtes mogelijk, terwijl de benodigde ruimte en installatiekosten worden verminderd. Door het compacte ontwerp zijn de spoelvereisten zeer laag, wat de bedrijfskosten verlaagt. Dankzij een zeer configureerbaar ontwerp kan de T-flensoplossing eenvoudig worden aangepast aan verschillende configuraties en toepassingen; individuele analysers kunnen eenvoudig worden vervangen. De certificeringen van de respectievelijke analysers, b.v. EX-d of SIL2 blijven behouden bij gebruik in de T-flensoplossing. Een typische toepassing is verbrandingsanalyse waarbij de T-Flange in combinatie met een LaserGas™ III O2 en een LaserGas™ III CO Ultra de perfecte oplossing is voor procesoptimalisatie en veiligheid.
  • ZFDM-4 Flue Gas Dust Monitor

    Accurate back scattering

    dust monitor

    Robust and accurate back scattering dust monitor for rough industrial installations

    QAL1 certified continuous monitoring of particulates concentration. Thanks to the backscattering technology, the LED light beam provides an accurate measurement (insensitive to ambient light). The self-checking anti-fouling functions and the continuous automatic correction system correct possible measurement drifts. This device is suitable for small and medium diameter ducts, for very low and medium dust concentrations as well as for light to dark coloured particles.
  • ZPA

    5 components analyser - NDIR single beam

    ZPA is best suited to the measurement of exhaust gas from refuse incinerators, boilers, and various industrial furnaces.

    NO, SO2, CO2, CO, CH4 Non-dispersion infrared-ray absorption methodSingle  light  source  and  single  beams  (single  beam system) O2 : Galvanic fuel cell O2 analyzer (built-in) paramagnetic O2 analyzer (built-in), or zirconia O2 analyzer (externally installed TYPE: ZFK7)
  • Fuji Electric Extractive Gas Analyzers for process control and continuous measurement of stack emissions. Their QAL1 certification guarantees high performance and regulatory and normative compliance. Reliable and precise, their design quality guarantees 24-hour operation in difficult environments such as smoke from industrial chimneys. Robustness reduces maintenance costs and increases the availability of boilers and equipment. Extractive measurement consists of taking a gas flow from the chimney or the gas pipe via a sampling probe and conveying it to the gas analyzer. The gas is sampled, treated in order to ensure optimal conditions for gas measurement.
  • Microventuri based continuous monitoring of flue gas flow rate, pressure and temperature
    Designed for tough industrial applications with highly dusts loaded fl ue gas.
  • Flue Gas Humidity Monitors Delta-O2

    In-situ or extractive O2 + H2O monitors
    Continuous measurement of humidity in highly dusts loaded flue gas through dry and wet zirconia oxygen measurements. In-situ or extractive O2 + H2O monitors depending on the application. Perfect for combustion control of biomass boilers : industrial boilers, district heating.
    O2 DRY  -  O2 WET -  H2O
  • iFiD NMHC

    The stationary Flame-Ionisation-Detector
    The stationary Flame-Ionisation-Detector (FID) iFiD NMHC measures with its built in NMHC Cutter the methane concentration and parallel in a second channel also the THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability. All components which come in contact with sample are fully heated at 200°.
  • iFiD NMHC Mobile

    The stationary Flame-Ionisation-Detector

    19" RackFlame-Ionisation-Detector iFiD Rack for continuous monitoring

    The stationary Flame-Ionisation-Detector (FID) iFiD RACK is designed for stack monitoring, process control and also for VOC measurement. The whole gaspath is heated to 300°C and so we can speak from a Hightemperature-FID.
  • LaserInspect CIMO4

    All-in-one controle paneel voor de LaserGas™ familie
    NEO Monitors’ LaserInspect™ CIMO4 gives the operator the opportunity to remotely operate up to 4 LaserGas™ analyzers from the same display*. The operator have full status overview in an instance of all instruments and is able to perform maintenance tasks directly from the panel. This HMI is designed for the NEO Monitors LaserGas™ family and can easily be integrated into a cabinet. * Separate Ethernet switch is required to operate multiple analyzers
  • Portable Multicomponent IR Analyzer

    CO, CO2, CH4, CnHm,O2, H2 + BTU index (gas calorific value)
    The analyzers can measure the concentration of multiple gases simultaneously. It is based on the single source dual-beam non-dispersion infrared (NDIR) method for CO, CO2 , CH4 , CnHm, H2S , SO2 and a micro-TCD (Thermal Conductivity Detector) gas sensor for H2 and O2 by fuel cell method. The analyzers have a digital pulsable infrared source and dual-beam systems
  • The analyzers can measure the concentration of multiple gases simultaneously. It is based on the single source dual-beam non-dispersion infrared (NDIR) method for CO, CO2 , CH4 , CnHm, H2S , SO2 and a micro-TCD (Thermal Conductivity Detector) gas sensor for H2 and O2 by fuel cell method. The analyzers have a digital pulsable infrared source and dual-beam systems
  • Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
  • Portable Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
  • The UT-3000 Ng mobile is specifically designed to measure ultratrace amounts of mercury in natural gas at differing sites. The system, for example, thus allows to monitor the efficiency of different Mercury Removal Units (MRUs) in natural gas processing plants.
  • GPR 1600/2600/3100

    Percent and PPM O2 Monitoring in Bulk Gases
    Ons assortiment zuurstofanalysatoren is ontworpen om gas te bewaken dat wordt geproduceerd of gebruikt in industriële processen waar zuurstofspoor van lage deeltjes per miljoen tot pure O2 nauwkeurig moet worden gemeten. Door gebruik te maken van de hoogwaardige galvanische zuurstofsensoren van AII zijn deze geavanceerde instrumenten eenvoudig te gebruiken met een gemeenschappelijke HMI en menustructuur voor het hele bereik. Operators hoeven slechts één instrument te leren voor meerdere gasanalysetoepassingen bij verschillende zuurstofniveaus. Verkrijgbaar als bench-, 19 "rack-, panel- en wandmontage voor flexibele installatie.
  • AII GPR-1200/3500

    Gemakkelijke tracering en meting van zuivere zuurstof
    De zeer nauwkeurige draagbare zuurstofanalysatoren van Analytical Industries zijn bedoeld voor toepassingen die op verschillende gedefinieerde meetpunten moeten worden gecontroleerd. Het GPR-3500-model heeft een compacte, robuuste behuizing en bevat roestvrijstalen onderdelen die in contact komen met de vloeistof, geïntegreerde debietmeters en naaldventielen. Het meet de zuiverheid voor inerte gassen, kooldioxide en zuurstof. De GPR-1200 compacte draagbare zuurstofanalyser voor sporen heeft een 4-wegklep die een gasmonster in de sensor opvangt. Dit maakt snellere zuurstofmeettijden mogelijk bij het verplaatsen van punt naar punt in een proces en beschermt ook sporenzuurstofsensoren tegen voortijdige uitputting als gevolg van blootstelling aan omgevingszuurstofniveaus om hun levensduur te verlengen. Dit alles zorgt voor een zuinige werking en lage eigendomskosten voor deze toonaangevende reeks draagbare zuurstofanalysers.
  • GPR-1000/1100/2000/ 3500 MO

    Voor steekproeven ter plaatse van PPM tot 100% zuurstof
    Deze robuuste draagbare instrumenten zijn geschikt voor sporen zuurstofmetingen van 0,1 ppm tot zuiverheid toepassingen bij 100% zuurstof en delen dezelfde geavanceerde sensortechnologie als de online proces zuurstof analysatoren, waardoor u kunt vertrouwen op hun betrouwbaarheid en nauwkeurigheid. Het concept van Analytical Instruments, waarbij dezelfde HMI en menustructuren worden gebruikt voor draagbare en online analysers, maakt het voor operators uiterst eenvoudig om beide soorten instrumenten op hun locatie te gebruiken zonder dat er extra training nodig is.
  • PFM 92 C

    Filter monitoring device
    • filter monitor for in-situ dust measurement
    • compact device consisting exclusively of the probe
    • suitable for the construction of filter monitoring systems
  • PFM 02 HB

    Residual dust sensor
    • residual dust sensor for wood processing industry with the EC-type examination certificate
    • compact device
    • suitable for the construction of filter monitoring systems
  • PFM 02 EX

    Filter monitoring device
    • filter monitor for in-situ dust measurement with EC-Type Examination Certificate (IBExU04ATEX1249 X)
    • approved for Ex II 1 / 3D Ex ia / tc IIIC T74 ° C Da / Dc and Ex II 3G Ex nA IIC T4 Gc ic
    • compact device
    • display showing the measured value in mg/m³ or in line diagram

Titel

Ga naar de bovenkant