• Fuji Electric Extractive Gas Analyzers for process control and continuous measurement of stack emissions. Their QAL1 certification guarantees high performance and regulatory and normative compliance. Reliable and precise, their design quality guarantees 24-hour operation in difficult environments such as smoke from industrial chimneys. Robustness reduces maintenance costs and increases the availability of boilers and equipment. Extractive measurement consists of taking a gas flow from the chimney or the gas pipe via a sampling probe and conveying it to the gas analyzer. The gas is sampled, treated in order to ensure optimal conditions for gas measurement.
  • FDS 15

    real-time measurement (PM10 or PM2.5)

    Optical sensor for continuous measurement and monitoring of fine dust contents indoor and outdoor.

    • optical sensor for continuous measurement and monitoring of fine dust concentrations (PM10, PM2.5)
    • smart, robust, network-capable
    • simple unit design
    • installation without any special tools
  • FDS 17

    simultaneous real-time measurement of PM10/ TSP and PM2.5
    • optical sensor for continuous, simultaneous measurement and control of fine dust contents PM10/TSP and PM2,5
    • patented zero point control by electrostatic precipitator
    • smart, robust, network-capable
    • simple unit design
    • installation without any special tools
  • FDS 17 m

    Simultane real-time meting van PM10 & PM2.5
    • simultaneous real-time measurement of PM10 & PM2.5
    • based on optical sensor, active suction & patented electrostatic precipitator for zero point setting
    • flexible use - indoors & outdoors -
    • portable case with offline power supply by power bank
    • including data logger for storage of measuring values
  • FDS 18

    Real-time measurement of PM2,5 
    • real-time measurement of PM2,5
    • Monitoring of fine dust concentrations in ambient air and/or at workplaces
    • optical sensor including fitting with clip system, therefore easily exchangeable
    • active and automatic zero point setting
    • active air suction
    • Integrated pre-separator for particles > 2,5 µm
    • noiseless operation
    • network-compatible
  • FID 1230 IH

    The flame-ionization-detector 1230 IH for continuous high temperature (400°C) monitoring of THC

    High-Temperature Analyzer for Exhaust gas measurement

    The flame-ionization-detector 1230I-H can measure the sum of total hydrocarbon concentrationin applications like cold starts of engines (down to–40°Cambient temperature), inwoodburning systems and also at engine test units (especially oil-and gasburners, airplaneengines etc.) Our high temperature heated lines with a operation temperature of 400°C are made additionally for measurements of highboiling hydrocarbons. For the sample-gas pickup we have built some prefilters who are able to hold back the tar compounds.
  • FID 1230 Module

    Vlam-Ionisatie-Detector 1230 Module voor continue monitoring van CxHy

    19" rack version Flame-Ionisation Detector FID 1230

    The Flame-Ionisation-Detector FID1230 Module measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy. Because of the module system, there is an optimal configuration for every measurement-task under profit aspects possible. All modules can be fit in at any time.
  • FID 1230 NMHC

    Methane only / CxHy monitoring system (Change-over switch)
    Methane only / Total Hydrocarbon THC monitoring system (Change-over switch) The 19” Flame-Ionisation-Detector (FID) 1230NMHC measures with its built-in NMHC-Cutter the methane concentration (methane only) and after switching to THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability.
  • FID 2000 MP

    Analytical section heated on 200°C
    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in a wide range of applications like all kind of emission control, catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air (immissions), solvent recovery plants and vehicle exhaust gases. The monitoring is continous with a high accuracy.
  • FID 2000MP SHED

    Connection for 4 calibration gases

    Mini/Micro-SHED

    The Flame-Ionisation-Detector (FID) 2000 MP measures the concentration of Total Hydrocarbons in SHED-chambers of different sizes. For applications beginning of 2,5m3 we recommend to measure in a heated circular system to get a response time near to real changes of concentration in the chamber. For smaller chambers, we have developed a special FID-analyzer with a sample flow of 12ml/min. These two types of analyzers optimizethe air change rateover the extraction rate.
  • FID 2010 NMHC

    Draagbare Methaan/CxHy Analyser

    Methaan/THC Analysator

    De draagbare verwarmde FID 2010 NMHC van TESTA meet met zijn ingebouwde NMHC-cutter de methaanconcentratie (alleen methaan) en na overschakeling op een ander kanaal ook de THC in een breed scala aan toepassingen zoals bewaking van schoorsteengasemissies, bewaking van omgevingslucht, monitoring van thermische reactor- en verbrandingsemissies en ook uitlaatgassen van voertuigen. De monitoring is continu met een hoge nauwkeurigheid, gevoeligheid en stabiliteit. Alle componenten die in contact komen met het monster worden volledig verwarmd op 200°.
  • FID 2010 T

    Draagbare Vlam-Ionisatie-Detector FID 2010T voor continue monitoring van CxHy - Classic Line

    Total Hydrocarbon Analyser

    The Flame-Ionisation-Detector 2010 T measures Total HydroCarbon (THC) in a wide range of applications like catalytic- and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases.By it`s little weight and it`s compact dimensions, he is especially made for daily changing measuring points or shorttime measurings campains.
  • FID 3001W

    Analytical section heated on 300°C

    Wall mount Flame-Ionisation-Detector 3001W

    The Flame-Ionisation-Detector 3001W measures Total Hydrocarbons in a wide range of applications like catalytic - and thermal oxidiser plants, waste gas processing plants, room and environmental air, solvent recovery plants and vehicle exhaust gases. Because of its swingable housing, there is an easy installation and optimal accessibility guaranteed. This wallmounted analyser is a compact, robust weatherproofed version. The environmental protectionmode is IP65.
  • The heated prefilter model iFiD Filter is a gasfilter for the high temperature applications who need a permanent temperature up to 300°C. The filter is very stable with the temperature level you can preselected. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of +-1%.
  • The filterinlet model iFiD Filter is a flashbackable filterunit for all heated Testa Samplegasfilters. The filter is usable for exhaust gas from engines as well as for emmission measuring tasks.
  • FL007

    Olie in water analyser
    The Kemtrak FL007 is a fiber optic probe based oil in water monitor. A state-of-the-art combined fluorescence and turbidity measurement assures reliable continuous monitoring of oil and hydrocarbon contamination in water. Mineral oils rich in aromatic content will fluoresce when illuminated with ultraviolet light. The intensity of this fluorescence is dependent upon the polyaromatic hydrocarbon (PAH) content of the oil. Typical oils that fluoresce include fuel oil, crude oil, hydraulic oil and transformer oil.
  • Microventuri based continuous monitoring of flue gas flow rate, pressure and temperature
    Designed for tough industrial applications with highly dusts loaded fl ue gas.
  • Flue Gas Humidity Monitors Delta-O2

    In-situ or extractive O2 + H2O monitors
    Continuous measurement of humidity in highly dusts loaded flue gas through dry and wet zirconia oxygen measurements. In-situ or extractive O2 + H2O monitors depending on the application. Perfect for combustion control of biomass boilers : industrial boilers, district heating.
    O2 DRY  -  O2 WET -  H2O
  • Gas Sample Probe Series ASP

    Verwarmd, modulaire opbouw met vele opties
    Due to its modular design and various options, the Ankersmid heated sample probe filters cover the widest range of applications. With a choice of different lengths of heated filter body, a filter element of 150mm length, suitable for most applications up to 1g dust/m3 can be integrated. 180mm filters with a larger filter surface are used for applications up to 4g dust/m3; with the blow- back function dust loads of up to 10g/m3 can be handled. The 500mm model filter of the ASP 1500 has a capacity for dust up to 10g/m3. When this type is equipped with blow-back option, it handles up to 20g/m3. For even higher dust loads, a primary filter is positioned on top of the first filter. A significant advantage is that all filters are replaceable without dismounting the probe without using any tools and in the shortest possible time. Cleaning and exchanging of unheated sample tubes or preliminary top-filters can be affected by extracting the filter from the probe. The probe temperature is controlled by a microprocessor based PID-controller (optional with Modbus/RS485 communication). Alarm or fault contacts can be programmed and the temperature can be changed easily. The standard sensor is PT100, whereas a thermo-couple is standard for the high temperature version.
  • The Ankersmid Humidifier controls the humidity of the gas sample stream. The Humidifier is used to wet calibration gases to ensure these gases undergo an identical cycle through the conditioning set-up.

    In this set-up, the calibration gases enter the cooler saturated at a stable dew point. Calibration gases with water-soluble components must not be passed through the humidifier.

  • GMD 12

    Gravimetrisch meetsysteem
    • intelligent system for isokinetic dust and fine particles measurements in exhaust air ducts and stacks
    • acquisition of all necessary gas boundary parameters (humidity of the sample gas, velocity in exhaust gas channel, temperature, pressure)
    • pivotable graphic display for more convenient operations
  • GMD 13

    Gravimetrisch meetsysteem
    • patented world innovation: Sampling and weighting in one system on site!
    • intelligent system for isokinetic dust and fine particles measurements in exhaust air ducts and stacks
    • acquisition of all necessary gas boundary parameters (humidity of the sample gas, velocity in exhaust gas channel, temperature, pressure)
    • pivotable graphic display for more convenient operations
  • GPR 1600/2600/3100

    Percent and PPM O2 Monitoring in Bulk Gases
    Ons assortiment zuurstofanalysatoren is ontworpen om gas te bewaken dat wordt geproduceerd of gebruikt in industriële processen waar zuurstofspoor van lage deeltjes per miljoen tot pure O2 nauwkeurig moet worden gemeten. Door gebruik te maken van de hoogwaardige galvanische zuurstofsensoren van AII zijn deze geavanceerde instrumenten eenvoudig te gebruiken met een gemeenschappelijke HMI en menustructuur voor het hele bereik. Operators hoeven slechts één instrument te leren voor meerdere gasanalysetoepassingen bij verschillende zuurstofniveaus. Verkrijgbaar als bench-, 19 "rack-, panel- en wandmontage voor flexibele installatie.
  • GPR-1000/1100/2000/ 3500 MO

    Voor steekproeven ter plaatse van PPM tot 100% zuurstof
    Deze robuuste draagbare instrumenten zijn geschikt voor sporen zuurstofmetingen van 0,1 ppm tot zuiverheid toepassingen bij 100% zuurstof en delen dezelfde geavanceerde sensortechnologie als de online proces zuurstof analysatoren, waardoor u kunt vertrouwen op hun betrouwbaarheid en nauwkeurigheid. Het concept van Analytical Instruments, waarbij dezelfde HMI en menustructuren worden gebruikt voor draagbare en online analysers, maakt het voor operators uiterst eenvoudig om beide soorten instrumenten op hun locatie te gebruiken zonder dat er extra training nodig is.
  • GPR-7100

    Kosteneffectieve monitoring van waterstofsulfide niveaus
    De GPR-7100 is een draagbare H2S-analyser-versie die bij voorkeur wordt gebruikt voor het ter plaatse controleren van het proces of tijdelijk gebruik tijdens onderhoud of inbedrijfstelling van een permanente gasanalysator. Deze geavanceerde instrumenten van AII zijn goedgekeurd voor gebruik in ontvlambare gasstromen.
  • GPR-7500

    Kosteneffectieve monitoring van waterstofsulfide niveaus
    De GPR-7500-analyser maakt gebruik van de elektrochemische sensortechnologie met laag vermogen om een ​​kosteneffectieve en gemakkelijk te onderhouden online-installatie waterstofsulfide meting in een klein pakket te bieden.
  • Heated Inlet Protection Filter model number 1035 is made for filtering the particles from a size of 5μ and bigger out of the samplegas. The Operation time of an Testa-FID without a build in filter (Model 123) can lengthened several times, because this fine filter helps to minimize the change of the sample capillary, the cleaning of the pump and minimize the maintenance. All the spikes you can see without filter are eliminated with our model 1035.
  • Heated Prefilter

    Model iFiD Filter XL
    The heated prefilter model iFiD FIlter XL is a samplegasfilter for the high temperature applications with a permanent temperature of 300°C. The filter is very stable with the temperature level you preselect, and also in permanent operation. In permanent use the maximum temperature is 300°C. The temperature is regulated in a range of + 1%.
  • Heated solenoid valve

    for SHED chamber

    Modell iFiD SHED

    The heated solenoid-valve prevents dilution or increase of the measurement gas concentration by giving up zero gas as well as test gas during or before the shed test measurement.
  • The heated transferline is made of a stainless steal tube with soldered heater. This construction is unique in relation to other lines and is guarantee for a very good heattransfer. Especially in cases of alternating process temperatures, the sample temperature can stabilized at preselected level. A Low-Cost-Version is available with simple teflon hose.
  • High Pressure STA HP 1/2

    Only available high pressure STA ( High pressure TGA-DSC)

    The LINSEIS High Pressure STA ( High pressure Tg-DSC) delivers unsurpassed performance. The system can be used to determine simultaneous changes of mass (TG) and caloric reactions (HDSC) under defined atmosphere and high pressure (up to 50/150 bar) in the temperature range -170°C up to 1800°C. This instrument is unique because it is the only available high pressure TG-DSC worldwide. The unique characteristics of this product are high precision, high resolution and long term drift stability. The high pressure STA Platinum Series was developed to meet the challenging demands of the high temperature and high pressure applications. Main Application of High Pressure Thermogravimetry-Differential Scanning Calorimetry:
    • Pyrolysis Studies
    • Gasification of Coal and Biomass
    • Testing of Getter Materials (O2, H2, etc.)
    • Metal reduction / oxidation studies
  • Hydrogen Analysers

    Thermal Conductivity Gas Analyser ZAF and ZAFE
    Reliable process control for furnaces, metal industry, semiconductor and gas separation. The analyser continuously measures the concentration of gases such as H2, He, and Ar with high stability. It is also available in a version for hazardous areas (for countries outside the European Union): ZAFE certified Ex NEPSI.
  • iFID Dual

    Continuous monitoring of two parallel channels

    19" RackFlame-Ionisation-Detector iFiD Rack for continuous monitoring of 2 channels parallel

    The stationary Flame-Ionisation-Detector iFiD Dual is designed for measuring at two points with one unit. This saves money in comparison to a 2 unit solution. The channels are separated from each other and so you can permanently measure high and low concentrations paralell without switching procedure.
  • iFID Mobile

    Draagbare Vlamionisatiedetector voor continue CxHybewaking

    Draagbare Vlamionisatiedetector

    De vlamionisatiedetector (FID) meet de totale koolwaterstofconcentratie in industriële en laboratoriumomgevingen. Door zijn lichtgewicht en compacte afmetingen is hij speciaal gemaakt voor dagelijks wisselende meetpunten of kortstondige metingen.
  • iFiD NMHC

    The stationary Flame-Ionisation-Detector
    The stationary Flame-Ionisation-Detector (FID) iFiD NMHC measures with its built in NMHC Cutter the methane concentration and parallel in a second channel also the THC in a wide range of applications like stack gas emissions monitoring, ambient air monitoring, thermal reactor and combustor emissions monitoring and also vehicle exhaust gases. The monitoring is continous with a high accuracy, sensitivity and stability. All components which come in contact with sample are fully heated at 200°.
  • iFiD NMHC Mobile

    The stationary Flame-Ionisation-Detector

    19" RackFlame-Ionisation-Detector iFiD Rack for continuous monitoring

    The stationary Flame-Ionisation-Detector (FID) iFiD RACK is designed for stack monitoring, process control and also for VOC measurement. The whole gaspath is heated to 300°C and so we can speak from a Hightemperature-FID.
  • iFiD Rack

    19" rack vlamionisatiedetector voor continue CxHy bewaking

    19" Rack vlamionisatiedetector voor continue CxHy bewaking

    De stationaire vlamionisatiedetector (FID) iFiD Rack is ontworpen voor stack monitoring, proces controle alsook voor VOC meting. Het volledige gaspad is verwarmd op 300°C, vandaar we kunnen spreken van een hoge temperatuur FID.
  • iFID Shed

    19" Rack Flame-Ionisation-Detector iFiD SHED for continuous monitoring

    19" Rack Flame-Ionisation-Detector iFiD SHED for continuous monitoring

    The stationary Flame-Ionisation-Detector (FID) iFiD SHED was designed as a 19" Rackunit. This analyzer is designed to measure volatile organic compounds in different sized SHED-chambers. The device is available in a bypass circuit version and an extraction version. The special advantage of the extraction version is a sample flow of only 12-15ml per minute. The whole gaspath is heated to 200°C and with its unique Pyrolysis cleaning system you can clean easily and save service costs.
  • iFID Wall

    Outdoor Vlamionisatiedetector iFiD voor continue CxHy bewaking

    Outdoor Flame-Ionisation-Detector iFiD Mobile for continuous monitoring

    The stationary Flame-Ionisation-Detector (FID) iFiD Wall is made for rough conditions and field installations. This unit measures the Total Hydrocarbon concentration especially in heavy industrial environment or freeair installations with small weatherprotection. The stainless steelhousing with a protection class IP65 gives the analyser a strong shelter all year long.
  • IGC SEA Surface energy analyzer

    Up to 12 different probe gas molecules
    The Inverse Gas Chromatography-Surface Energy Analyzer or iGC-SEA continues Surface Measurement Systems’ pioneering history with inverse gas chromatography (IGC). The iGC-SEA is a second generation Inverse Gas Chromatography instrument. It is the only commercial instrument based on IGC principle. The unique SMS injection scheme provides a wide range of injection concentrations with high accuracy and reproducibility.
  • In-situ zirconia oxygen gas analysers

    Fast response (4–7 seconds)
    Optimization of combustion efficiency and compliance with environmental standards Ideal for combustion control in boilers, incinerators and furnaces. Lowering CO₂, SOx, and NOx emissions while saving energy This oxygen analyser is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers or furnaces, and is ideally suited for combustion management and control, such as garbage incinerators and smallest to largest sized boilers, as combustion controllers, achieving a significant energy-saving effect.
  • LabAnalyzer 254

    0.01 ppb ... 10 ppb (10 ng/l to 10 µg/l)
    Rapid mercury determination in the laboratory
    • Firmly adjusted optical system not requiring any adjustment
    • Short analysis times
    • Low reagent consumption
    • Automatic zero adjustment
    • For analyses according to DIN 38406-12 / EPA 7470A / EPA 7471A)
    • Measuring range: 0.01 ppb ... 10 ppb (10 ng/l to 10 µg/l)
    • Hg trap: Mercury vapors cannot escape into the lab
    • Upgradable to VM-3000 Mercury Vapor Monitor
  • LaserDust

    Compacte optische in-situ stofmonitors
    LaserDust™ Medium Path (MP), Long Path (LP) en Extra Long Path (XLP) monitoren zijn compacte, optische stofmonitors voor echte continue in-situ meting van stofconcentratie of opaciteit. De monitoren zijn ontworpen voor metingen over pijpen, schoorstenen en kanalen met typische padlengtes van 0,5 – 10 m. LaserDust™-monitoren gebruiken een zender/ontvangerconfiguratie om de stofconcentratie langs de optische zichtlijn te meten. Onze echte contactloze benadering is superieur aan stofmeters van het punttype. Met innovatieve lasertechnologie combineert de LaserDust™ twee meetprincipes in één instrument.
    • Bij lage stofniveaus werkt het met voorwaartse strooilichttechnologie: Het invallende laserlicht wordt verstrooid door stofdeeltjes en verzameld op een solid-state sensor voor stofkwantificering. Deze zeer gevoelige modus maakt detectiegrenzen van < 0,5 mg/Nm3 mogelijk en wordt niet beïnvloed door stofafzetting op de vensters.
    • Bij hoge stofniveaus meet de LaserDust™ de doorlaatbaarheid of opaciteit: Lichtabsorptie door stofdeeltjes wordt opgevangen door een 2e sensor.
  • LaserGas II MP

    Compacte extractieve meting met lage detectielimieten
    LaserGas™ II Multi Pass combineert extractieve metingen met een compact analyserontwerp. De laserstraal wordt gekoppeld aan een meetcel, waar deze meerdere keren wordt gereflecteerd tussen twee bolvormige spiegels om de gevoeligheid van de analysator te vergroten. De monitor is een kant-en-klaar instrument. Tijdens de installatie zijn geen andere handelingen nodig dan het aansluiten van stroom, het meetgas en optionele spoeling. LaserGas™ MP biedt een betrouwbare en gebruiksvriendelijke oplossing voor een breed scala aan toepassingen.
  • LaserGas II OP

    Open pad gasmonitor over lange afstand
    LaserGas™ II Open Path is a compact, high performance gas monitor for ambient long distance monitoring. The LaserGas™ II OP consists of a transceiver and retro-reflector unit. The retro-reflector unit consists of one or several cube corners in a weather proof enclosure, which reflects the light back to the transceiver. The detector collects the returned light for calculation of the gas concentration. An optional auto-alignment unit can also be applied to ensure consistent alignment over time.
  • LaserGas II SP Compact

    Cross stack meting voor padlengtes van 10 - 100 cm

    De LaserGas-II-Compact Monitor is afgeleid van de standaard Single Path instrumenten en werd geoptimaliseerd voor toepassingen met korte padlengtes tussen 10 en 100 centimeter. Doordat het toestel is voorzien van een gefocuste laserstraal is het mogelijk door zeer dunne insteekbuisjes te meten (<10 mm diameter). Hierdoor is er bij de SP Compact, voor toepassingen waarbij spoeling van de lens ter voorkoming van stofafzetting noodzakelijk is, slechts een zeer beperkt spoeldebiet vereist. Met de optionele interne deshydratiemiddelen kunnen deze toestellen ook worden geoptimaliseerd voor in-situ meting van sporen niveaus van bv O2 en H2O. De LaserGasTMII SP Compact Monitor bestaat uit een zender / ontvanger (gemonteerd diametraal tegenover elkaar) om de gemiddelde concentratie gas langs de optische meetveld te bepalen.  
  • LaserGas II SP Hydrogen

    De eerste optische in situ H2 meter ter wereld!
    Neo Monitors is trots 's werelds eerste in-situ optische analysator voor waterstof aan te bieden. De LaserGas™ II Single Path Hydrogen is een speciaal ontworpen versie die is afgestemd op waterstofmetingen. De sensor blijft onaangetast door verontreinigingen, corrosieve stoffen en heeft geen regelmatig onderhoud nodig. De afwezigheid van extractieve conditioneringssystemen verbetert de beschikbaarheid van de metingen verder en elimineert fouten met betrekking tot monsterbehandeling. Zodra de voeding, datalijnen en spoeling zijn aangesloten, is het instrument klaar voor gebruik en worden metingen in realtime uitgevoerd.
  • LaserGas II SP Monitor

    Cross stack meting voor padlengtes van 0,5 - 20 m
    Single Path monitoren zijn ontworpen voor in-situ meting in schoorstenen, leidingen of reactoren met typische padlengte van 0,5 tot 20 meter. By-pass en extractieve configuraties zijn ook mogelijk. Het compacte ontwerp bestaat uit de zender (met laser module, de optische module en de belangrijkste elektronica) en de ontvanger (met focus lens, fotodetector en ontvanger elektronica). De LaserGas II SP Monitor maakt gebruik van een zender / ontvanger configuratie (diametraal tegenover elkaar gemonteerd) om de gemiddelde gasconcentratie over de optische padlengte te bepalen.

Titel

Ga naar de bovenkant