• PFM 97 ED

    Continuous, tribo-electric extractive measurement of dust contents in wet and sticky exhaust gases
    • extractive dust concentration measuring device
    • measurement in wet exhaust gases
    • triboelectric dust sensor
    • adapted design for application in blast furnace gas
  • PFM 92 C

    Filter monitoring device
    • filter monitor for in-situ dust measurement
    • compact device consisting exclusively of the probe
    • suitable for the construction of filter monitoring systems
  • PFM 14 K

    Mobiel systeem voor tijdelijke, tribo-elektrische in-situ filter monitoring van uitlaatgassen
    • mobile filter diagnosis unit for triboelectric in-situ monitoring of dust emissions
    • measuring probe with variable length to  adapt to the local conditions
    • immediate clean gas dust content monitoring after the dust collectors
    • offline power supply by power bank
    • integrated recorder
  • PFM 14

    Filter monitoring device
    • filter monitor for in-situ dust measurement
    • with separate operating unit
    • display showing the measured value in mg/m³ or line diagram
  • PFM 13 C EX

    Filter monitoring device
    • continuous, tribo-electric in-situ filter monitoring device with EC-Type Examination Certificate (IBExU19ATEXB008 X)
    • approved for Ex II 3D Ex ic tc IIIC T80 °C Dc
    • suitable for installations in hazardous areas of zone 22
    • no separate power supply necessary (2-wire transmitter)
    • two probe lengths available (300 and 500 mm)
  • PFM 13 C

    filter monitor for in-situ dust measurement
    • filter monitor for in-situ dust measurement
    • compact device
    • suitable for the construction of filter monitoring systems
  • PFM 13

    filter monitor for in-situ dust measurement
    • filter monitor for in-situ dust measurement
    • compact device with display
    • suitable for the construction of filter monitoring systems
  • PFM 06 ED

    Continuous, optical extractive measurement of dust contents in wet and sticky exhaust gases
    • extractive optic dust concentration measurement
    • measurement in wet, sticky exhaust gas conditions
    • optical dust sensor
    • suitability tested according to EN 15267-3 (QAL1)
    • approved for installations according to IED
  • PFM 02 HB

    Residual dust sensor
    • residual dust sensor for wood processing industry with the EC-type examination certificate
    • compact device
    • suitable for the construction of filter monitoring systems
  • PFM 02 EX

    Filter monitoring device
    • filter monitor for in-situ dust measurement with EC-Type Examination Certificate (IBExU04ATEX1249 X)
    • approved for Ex II 1 / 3D Ex ia / tc IIIC T74 ° C Da / Dc and Ex II 3G Ex nA IIC T4 Gc ic
    • compact device
    • display showing the measured value in mg/m³ or in line diagram
  • PFM 02

    Filter monitoring device
    • filter monitor for in-situ dust measurement
    • compact device
    • display showing the measured value in mg/m³ or in line diagram
  • This unique microprocessor controlled Peltier Cooler has been designed with a powerful dew point stabiliser. The dew point is set at 4°C but can be changed at any value between 1 and 15°C. The condensate that is formed should be removed by a peristaltic pump, automatic drain or collection vessel.

    The heat exchanger is demountable and PFA®-coated.

    The digital controlled cooler has many control and warning features like programmable alarms, mA-output, digital inputs and Modbus or RS485 communication. The alarm status changes when the temperature deviates by • ± 3 °C from the set point.

    Available for 230VAC and 115VAC power supply.

  • Paramagnetic O2 Analyzer

    0-100%, freely settable by input of parameters
    The APA analysers are suitable and reliable instruments for monitoring oxygen concentrations in various gas analytical control applications including flue gas-, inert gas-, fermentation processes- and process or laboratory control measurements. All analysers are temperature controlled instruments which have been designed for continuous measurements of oxygen concentrations in particle-free and dry sample gas. The analysers are reliable and easy-to-operate instruments. The measuring value and the sample flow through the measuring cell are displayed on the digital display. 2 alarm relays and 1 malfunction relay are available. Sample gas connections as well as connectors for incomi ng power supply, output signals are located at the rear panel of the analyser. The sample gas enters the analyser passing a protective fine-filter which is installed in the front-panel (not for APA 200). An atmospheric pressure sensor is implemented so that the actual absolute barometric pressure can be sent via RS232 and used for calculation or analysis purposes.
  • The APF front panel mounting reliably extra-fine filters solids, in particular very fine particles, from the gas stream for gas conditioning applications. The APF uses a very fine, deep-acting filter element that removes particles larger then 100 nanometer from the gas stream. The large filter surface of the cylindrical filter element guarantees reliable extra-fine filtration and a long service life with low pressure drop.

    The APF extra-fine filter was primarily developed for 19" front-plate mounting equipment, as is evident from the APF’s small size that is suited to flat-design equipment

  • PA-2 / PA-2 Gold

    Continuous monitoring of mercury in water and aqueous solutions
    The mercury process analyzer PA-2 is used for continuous monitoring of mercury concentrations in industrial processes. Applications include effluent and quality control in chlorine-alkali plants, monitoring of scrubber water of waste incinerators and power plants, control of industrial sewage and purification plants, quality control of sulphuric acid, drinking water. Special version also for concentrated caustic solutions (NaOH, KOH).
  • Ankersmid Ambient Air Filters AAF 051 / AAF 052 / AAF 053 are used for the filtration of ambient air in gas monitoring systems.

    The main applications are in ambient air monitoring and in air conditioning systems.

  • Odosense Smart

    Odour monitoring Device

    The Odosense Smart is a smart odour monitoring device specially developed to monitor odorants in the ambient atmosphere. The Odosense smart is a sensor-based IoT powered online odour monitor for peripheral monitoring across odourful sites and activities. So, the smart odour monitor is used for applications like monitoring in and around facilities like solid waste monitoring plants.

    Odour monitoring around solid waste plants, dump yards and landfills is very crucial as they are usually around the city vicinity and the odour nuisance could be a health hazard for the surrounding residents. It is also essential to keep a track of odour intensity to take suggestive actions like planning odour mitigation activities. Additionally, in the case of false complaints, the authorities have the data for reference purposes.

    Odosense Smart measures odourful parameters such as Sulfur Dioxide (SO2), Hydrogen sulphide (H2S), Ammonia (NH3), Methyl Mercaptan (CH3SH), TVOC (Benzene, Toluene, Xylene), Temperature and Humidity.

    The Odosense Smart is technologically equipped to offer higher accuracy with features such as patented e-breathing technology, Auto device firmware updates, and remote calibration capabilities. Additionally, our systems are backed with AI ML algorithms to understand odour levels and impact.

    Odosense Smart Odour Monitoring Device can transmit data through various data communication modules such as GSM, WiFi, LORA, etc. So, the data is transmitted to the Oizom cloud in near real-time. Additionally, it has an inbuilt memory backup to ensure no data loss in case of network failure. This ensures the best device uptime. The collected data can be visualized on the Oizom IoT Terminal in the form of real-time dashboards, upon collection on a dense network of data points and integrating weather data we can also generate odour plumes and odour dispersion heatmaps. By integrating data from the Odosense Smart onto 3rd party odour modelling platforms we can also enable advanced analytics on the odour levels.
  • Odosense Lite

    Real-time Odour Monitor

    The Odosense Lite is a real-time odour monitor specially developed to monitor bad and foul smells in the ambient atmosphere. The Odosense lite is a compact online odour monitor for peripheral monitoring across odourful sites and activities. The low-cost odour monitor is also used for applications like monitoring in and around wastewater treatment plants, waste management facilities, sewage odour monitoring and effluent water odour monitoring. Monitoring around wastewater treatment and sewage treatment plants are essential to keep a track of odour dispersion. Thus, it also enables the maintenance crew to take critical actions at the required intervals for e.g spraying neutralizers at odour hotspots, re-churning the treatment process etc. Odosense Lite measures odourful parameters like Sulfur Dioxide (SO2), Hydrogen sulphide (H2S), Ammonia (NH3), Temperature and Humidity. Odosense Lite measures odourful parameters like Sulfur Dioxide (SO2), Hydrogen sulphide (H2S), Ammonia (NH3), Temperature and Humidity. Oizom’s real-time odour monitor offers higher accuracy. Features like patented e-breathing technology, auto device firmware updates and remote calibration capabilities ensure this. Additionally, our systems are backed with AI ML algorithms to understand odour levels and impact. This Real-time odour monitor can transmit data through various data communication modules like GSM, WiFi, LORA, etc to the Oizom cloud on a real-time basis. Additionally, it has an inbuilt memory backup to ensure no data loss in case of network failure. This ensures the best device uptime. Oizom IoT Terminal – Envizom allows users to visualize data in the form of real-time dashboards. Upon collection on a dense network of data points and integrating weather data, users can also generate odour plumes and odour dispersion heatmaps. Similarly, by integrating data from the Odosense Lite onto 3rd party odour modelling platforms we can enable advanced analytics on the odour levels. Thus, the utilization of odour data extends to various industrial automation applications in an Industrial IoT (IIoT) environment.
  • nCLD EL²

    NO , NO2 , NOx - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD EL²

    Modular Gas Analyzer The nCLD EL2 analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD EL2 is modular designed and capable of simultaneously measuring NO, NO2 and NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD EL S

    NO / NOx - 5 ppm –5’000 ppm

    ECO PHYSICS nCLD EL S

    Gas Analyzer The nCLD EL S is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL S is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data. connects to other instruments’ data.
  • nCLD EL

    NO / NOx - 0.5 ppm -500 ppm

    ECO PHYSICS nCLD EL

    Gas Analyzer The nCLD EL is the next generation in single-channel NO/NOX measurement. Unique in speed and precision, the nCLD EL is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principle complies with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
  • nCLD AL²

    NO, NO2 , NOx - 100 ppb – 50 ppm
    Ambient Level Gas Analyzer The nCLD AL2 is the next generation in two-channel high precision ambient air monitoring instrumentation. Unique in speed and reliability, the nCLD AL2 is modular designed and capable of simultaneously measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD AL

    NO, NO2 , NOx - 100 ppb – 50’000 ppb
    Ambient Level Gas Analyzer  The nCLD AL is the next generation in single-channel high precision ambient air monitoring instrumentation. Unique in speed and reliability, the nCLD AL is modular designed and capable of sequentially measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 899 Y

    NO, NO2 , NOx - 1 ppb – 1’000 ppb
    SupremeLine Trace Gas Analyzer The nCLD 899 Y analyzer is the next generation in ultra high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 899 Y is modular designed and capable of detecting lowest quantities of NO, NO2 and NOX in the range of parts per trillion. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 88 Yp

    NO / NOx - 5 ppb – 5’000 ppb

    ECO PHYSICS nCLD 88 Yp

    Modular Trace-Level Gas Analyzer The nCLD 88 Yp is the next generation in measuring smallest amounts of NO or NOX. Unique in speed and precision, the nCLD 88 Yp is modular designed and allows the sequential measurement of concentrations even in the range of parts per trillion and is expandable to assess additional nitrogen oxide based parameters. Its new and intuitive user interface also individually displays and connects to other instruments’ data.
  • nCLD 855 Y

    NO, NO2 , NOx - 100 ppb – 50’000 ppb

    ECO PHYSICS nCLD 855 Y

    Modular Gas Analyzer The nCLD 855 Y analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 855 Y is modular designed and capable of simultaneously measuring NO, NO2 and NOX. The analyzer’s expandable capabilities allow assessment of hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 844 Mhr

    NO, NO2 , NOx - 0.5 ppm – 500 ppm

    ECO PHYSICS nCLD 844 Mhr

    Modular Gas Analyzer The nCLD 844 Mhr analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 Mhr is modular designed and capable of simultaneously measuring NO, NO2 and NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 844 Mh

    NO, NO2 , NOx - 0.5 ppm – 500 ppm
    Modular Gas Analyzer The nCLD 844 Mh analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 Mh is modular designed and capable of simultaneously measuring NO, NO2 and NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 844 M

    NO, NO2 , NOx - 0.5 ppm – 500 ppm

    ECO PHYSICS nCLD 844 M

    Modular Gas Analyzer The nCLD 844 M analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 M is modular designed and capable of simultaneously measuring NO, NO2 and NOX. The analyzer’s expandable capabilities allow assessment of hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 844 CMhr

    NO, NO2, NOx, NH3, NOx–amines - 0.5 ppm – 500 ppm

    ECO PHYSICS nCLD 844 CMhr

    Modular Gas Analyzer The nCLD 844 CMhr analyzer is the next generation in high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 CMhr is modular designed and capable of sequentially measuring NO, NO2, NOX, NH3 and NOX-Amines. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 84 M

    NO / NOx - 0.5 ppm –500 ppm

    ECO PHYSICS nCLD 84 M

    Modular Gas Analyzer The nCLD 84 M analyzer is the next generation in single-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 84 M is modular designed and capable of measuring NO or NOX. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 822 SSdhr

    NOx - NOx dual-channel - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 822 SSdhr

    Modular Gas Analyzer The nCLD 822 SSdhr analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 SSdhr is modular designed and capable of directly and simultaneously measuring NOX in rough samples from two hot and moist sources without additional gas preconditioning unit. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 822 Mr

    NO , NO2 , NOx - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 822 Mr

    Modular Gas Analyzer The nCLD 822 Mr analyzer is the next generation in high precision two-channel nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 Mr is modular designed and capable of simultaneously measuring NO, NO2 and NOX from sources with pressure variations. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 822 M

    NO , NO2 , NOx- 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 822 M

    Modular Gas Analyzer The nCLD 822 M analyzer is the next generation in two-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 M is modular designed and capable of simultaneously measuring NO, NO2 and NOX. The analyzer’s expandable capabilities allow assessment of hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 822 CMhr

    NO, NO2 , NOx , NH3 , NOx – Amines - 5–5’000 ppm

    ECO PHYSICS nCLD 822 CMhr

    Modular Gas Analyzer The nCLD 822 CMhr analyzer is the next generation in high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 CMhr is modular designed and capable of sequentially measuring NO, NO2 , NOX , NH3 and NOX-Amines from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 82 S

    NO / NOx - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 82 S

    Modular Gas Analyzer The nCLD 82 S analyzer is the next generation in single-channel high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 82 M is modular designed and capable of measuring NO or NOX . The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 82 Mh

    NO / NOx - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 82 Mh

    Modular Gas Analyzer The nCLD 82 Mh analyzer is the next generation in high precision single-channel nitrogen oxide measurement. Unique in speed and reliability, the nCLD 82 Mh is modular designed and capable of measuring NOX from hot and humid gas sources without additional cooler. The new and intuitive graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 811 M

    NO, NO2 , NOx - 1 ppm - 10’000 ppm

    ECO PHYSICS nCLD 811 M

    SupremeLine Gas Analyzer The nCLD 811 M is the next generation in two-channel emissions monitoring instrumentation. Unique in speed and reliability, the nCLD 811 M is modular designed and allows the continuous and simultaneous analysis of NO, NO2 and NOX in raw exhaust gasses with NOX concentrations ranging from several thousand ppm down to a ppb. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 811 CM

    NO, NO2, NOx, NH3, NOx – Amines - 1 ppm -10’000 ppm
    SupremeLine Gas Analyzer The nCLD 811 CM is the next generation in two-channel emissions monitoring instrumentation. Unique in speed and reliability, the nCLD 811 CM is modular designed and allows the continuous analysis of NO, NO2, NOX, NH3 and NOX-Amines in raw exhaust gasses and other samples with NOX concentrations ranging from several thousand ppm down to a ppb. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 66 Y

    NO / NOx - 50 ppb – 25’000 ppb

    ECO PHYSICS nCLD 66 Y

    Gas Analyzer The nCLD 66 Y is the next generation in single-channel ambient air monitoring instrumentation. Unique in speed and precision, the nCLD 66 Y is modular designed and capable of sequentially measuring NO, NO2 and NOX. The analyzers expandable capabilities allow assessment of additional nitrogen oxide based parameters. Its graphical user interface also individually displays and connects to other instruments’ data.
  • nCLD 63 MOx

    NO / NOx O2, CO2 - 0.5 ppm – 500 ppm

    ECO PHYSICS nCLD 63 MOx

    Multi-Gas Analyzer The nCLD 63 MOx is the next generation in measuring NO/NOx , O2 and CO2. Unique in speed and precision, the nCLD 63 MOx is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principles comply with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
  • nCLD 62 MOx

    NO / NOx O2, CO2 - 5 ppm – 5’000 ppm

    ECO PHYSICS nCLD 62 MOx

    Multi-Gas Analyzer The nCLD 62 MOx is the next generation in measuring NO/NOX , O2 and CO2. Unique in speed and precision, the nCLD 62 MOx is modular designed and allows the continuous measurement of concentrations in the range of parts per million. The measuring principles comply with international emissions monitoring regulations and its new and intuitive user interface individually displays and connects to other instruments’ data.
  • NBP007

    NIR Backscatter Photometer
    The Kemtrak NBP007 is a high resolution backscatter photometer that revolutionizes the measurement of high concentration suspended solids. Traditional turbidity based optical measurement instruments lack resolution and stop working at approximately 1% suspended solids due to the extremely high optical density. This limitation is overcome with the NBP007 and for the first time the operator can monitor and have complete control over their process at any concentration. By knowing exactly what is happening at all times, process changes can be quickly implemented that result in substantial cost savings.
  • For measuring mercury in natural gas the pressure of a high pressure sample feed has to be reduced to a suitable low pressure before measurement. The new NG-SAMPLING SYSTEM-3000 follows a straight forward design. It integrates a minimum of components. All gas wetted parts in the sample path have been silicon coated. This allows very fast conditioning and low memory effects.  
  • The analyzers can measure the concentration of multiple gases simultaneously. It is based on the single source dual-beam non-dispersion infrared (NDIR) method for CO, CO2 , CH4 , CnHm, H2S , SO2 and a micro-TCD (Thermal Conductivity Detector) gas sensor for H2 and O2 by fuel cell method. The analyzers have a digital pulsable infrared source and dual-beam systems
  • MP470

    Video Melting Point Apparatus
    MP420/MP430 Video Melting Point Apparatus, and MP450/MP470/MP490 Automatic Video Melting Point Apparatus, perfectly integrate video technology into melting point measuring. It not only provides users with reliable melting point test result, but also intuitively displays temperature curve and real-time video image, and achieves the function of save, replay the video,stamp video and so on. It also provides better help for users to observe melting process of sample.
  • The gasstation is fitted with all supplygases who are necessary for a FID measurement. Hydrogen as the fuel gas, nitrogen as zerogas and propane as the calibration gas are available in the one liter bottles who allows a very good handling in mobile measurement. The FID can be connected via teflon hoses and quick connectors.
  • MMS-NG

    1 pg absolutely or 0.1 ng/m³
    Automatic systemdesigned for continuous mercury monitoring in natural gas even in hazardous zones (ATEX, IEC-Ex)
    Each mercury on-line system will differ in sample characteristics as well as installation conditions and operating environment. We have the experience to design systems that fully meet the requirements of your particular mercury monitoring task.

Titel

Ga naar de bovenkant